1SDA107597R1 ABB XT6H 800 Ekip Dip LSI In=630 4P F F

1SDA107597R1 ABB XT6H 800 Ekip Dip LSI In=630 4P F F

ABB 1SDA107597R1 is a fixed four-pole SACE Tmax XT6H 800 moulded-case circuit breaker with a 630 A Ekip Dip LSI electronic trip unit, front terminals and 70 kA ultimate short-circuit breaking capacity at 400/415 V AC.

SKU: 1SDA107597R1MPN: 1SDA107597R1
Price
List Price £3,457.19 ex VAT
Your Price (ex VAT) Save 25%
£2,592.89 25% OFF
You save £864.30 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,592.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,592.89

Why Choose the ABB 1SDA107597R1 XT6H 800 Ekip Dip LSI 630A Circuit Breaker?

The ABB 1SDA107597R1, designated XT6H 800 Ekip Dip LSI In=630 4p F F, is a four-pole ABB SACE Tmax XT6 moulded-case circuit breaker designed for advanced protection of demanding low-voltage AC distribution systems. It combines the XT6H 800 frame with a 630 A Ekip Dip LSI solid-state trip unit, providing electronic long-time, short-time and instantaneous protection.

The XT6H offers ABB's high short-circuit performance level, with an ultimate short-circuit breaking capacity of 70 kA at 400/415 V AC. Its Ekip Dip LSI release provides adjustable protection functions that support overload protection, selective short-circuit coordination and rapid interruption of high fault currents.

The 1SDA107597R1 is supplied as a four-pole fixed circuit breaker with front terminals. With a 630 A continuous current rating, electronic LSI protection and the high-breaking-capacity XT6H platform, it is well suited to industrial, commercial and infrastructure switchboards where dependable protection and coordination are essential.

Key Advantages

  • Genuine ABB SACE Tmax XT6 moulded-case circuit breaker.
  • 630 A Ekip Dip LSI electronic trip unit.
  • Provides long-time, short-time and instantaneous protection functions.
  • Four-pole construction for three-phase and neutral distribution systems.
  • High 70 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • Fixed mounting with front terminals for conventional switchboard integration.
  • Adjustable electronic protection supports effective selectivity and coordination within complex distribution networks.

Key Features

  • ABB SACE Tmax XT6H 800 frame.
  • Ekip Dip LSI solid-state release.
  • Rated current: 630 A.
  • Protection functions: L, S and I.
  • Overload release setting: 252–630 A.
  • Short-time short-circuit setting: 630–6300 A.
  • Instantaneous short-circuit setting: 630–6300 A.
  • Number of poles: 4.
  • Mounting: Fixed.
  • Main terminals: Front.
  • Operating mechanism: Toggle.
  • Front degree of protection: IP20.

Advanced LSI Protection for High-Capacity Distribution

The Ekip Dip LSI release provides three complementary electronic protection functions. Long-time protection responds to sustained overload conditions, short-time protection supports selective coordination during short circuits, and instantaneous protection provides rapid interruption when severe fault currents occur. The overload setting covers 252–630 A, while both short-time and instantaneous short-circuit settings cover 630–6300 A.

Combined with the XT6H high-breaking-capacity frame, this protection architecture makes the 1SDA107597R1 suitable for distribution systems with substantial prospective fault currents. Its 70 kA breaking capacity at 400/415 V AC, four-pole construction and fixed front-terminal arrangement provide a robust solution for integration into high-capacity low-voltage switchboards.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • Commercial and infrastructure electrical distribution.
  • Four-wire three-phase AC distribution systems.
  • Feeder and distribution circuit protection.
  • Installations requiring high short-circuit breaking capacity.
  • Systems requiring electronic LSI protection and selective coordination.
  • Fixed MCCB installations requiring a 630 A electronic trip unit.

Technical Specifications

Series SACE Tmax XT / Tmax XT 250 Range
Order code 1SDA107597R1
Product type Moulded-case circuit breaker (MCCB)
Product main type SACE Tmax XT
Frame size XT6
Frame designation XT6H 800
Trip unit Ekip Dip LSI
Trip unit technology Solid-state / electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Rated current 630 A
Overload release setting 252–630 A
Short-time short-circuit release setting 630–6300 A
Instantaneous short-circuit release setting 630–6300 A
Number of poles 4
Current type AC
Mounting Fixed
Terminal arrangement Front terminals
Operating mechanism Toggle
Short-circuit performance level H
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity at 400/415 V AC 70 kA
Front degree of protection IP20
Power loss 33.2 W
Product net width 280 mm
Product net height 268 mm
Product net depth 103.5 mm
Product net weight 12 kg
Minimum order quantity 1 piece
EAN / GTIN 8015644102500
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA107597R1?

The 1SDA107597R1 is an ABB SACE Tmax XT6H 800 four-pole moulded-case circuit breaker with a 630 A Ekip Dip LSI solid-state trip unit, fixed mounting and front terminals.

What is the rated current of the ABB 1SDA107597R1?

The circuit breaker has a rated current of 630 A and uses ABB's Ekip Dip LSI electronic protection unit.

What protection functions does Ekip Dip LSI provide?

The Ekip Dip LSI trip unit provides long-time overload protection, short-time short-circuit protection and instantaneous short-circuit protection, represented by L, S and I.

What is the breaking capacity of the ABB XT6H 1SDA107597R1?

The XT6H configuration provides an ultimate short-circuit breaking capacity of 70 kA at 400/415 V AC, making it suitable for installations with high prospective fault currents.

What does XT6H 800 Ekip Dip LSI In=630 4p F F mean?

XT6H 800 identifies the XT6 frame and H short-circuit performance level, Ekip Dip LSI identifies the electronic trip unit, In=630 specifies the 630 A rated current, 4p denotes four poles, and F F identifies fixed construction with front terminals.

Trusted ABB High-Performance Circuit Protection

ABB SACE Tmax XT moulded-case circuit breakers combine robust construction with configurable electronic protection, with the 1SDA107597R1 delivering 630 A four-pole Ekip Dip LSI protection and 70 kA breaking performance at 400/415 V AC for demanding low-voltage distribution applications.