1SDA107582R1 ABB XT6S 800 TMA 630-6300 4P Fixed Circuit Breaker

1SDA107582R1 ABB XT6S 800 TMA 630-6300 4P Fixed Circuit Breaker

ABB 1SDA107582R1 SACE Tmax XT6S 800 fixed four-pole moulded-case circuit breaker with 630 A rated current, fully rated neutral, front terminals and adjustable TMA thermomagnetic protection.

SKU: 1SDA107582R1MPN: 1SDA107582R1
Price
List Price £2,534.00 ex VAT
Your Price (ex VAT) Save 25%
£1,900.50 25% OFF
You save £633.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,900.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,900.50

Why Choose the ABB 1SDA107582R1 XT6S 800 Circuit Breaker?

The ABB 1SDA107582R1, designated XT6S 800 TMA 630-6300 4p F F InN=100%In, is a four-pole fixed SACE Tmax XT6S moulded-case circuit breaker designed for low-voltage AC and DC power distribution applications. Built on ABB's XT6 800 A frame, this configuration has a rated current of 630 A, front terminals and a four-pole thermomagnetic TMA protection release.

The integrated TMA thermomagnetic trip unit provides adjustable overload and instantaneous short-circuit protection. ABB specifies a thermal current setting range of 0.7–1 × In, corresponding to approximately 441–630 A, together with an instantaneous magnetic protection range of 3150–6300 A. This allows the breaker to be adapted to the protection requirements of suitable feeders and distribution circuits.

The XT6S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC. This four-pole version also features a fully rated neutral at 100% of phase rated current, making it suitable for distribution systems where the neutral conductor must carry the full rated current of the breaker.

Key Advantages

  • Genuine ABB SACE Tmax XT6S moulded-case circuit breaker.
  • 630 A rated current on the XT6 800 A frame.
  • TMA thermomagnetic trip unit with adjustable overload and instantaneous protection.
  • 50 kA ultimate breaking capacity at 415 V AC.
  • Four-pole configuration with fully rated neutral at 100% of phase rated current.
  • Fixed mounting with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT6S moulded-case circuit breaker.
  • XT6 800 A frame size.
  • 630 A rated current.
  • Four-pole configuration.
  • Fully rated neutral: InN = 100% In.
  • Fixed mounting configuration.
  • Front terminals for main power connections.
  • TMA thermomagnetic protection release.

Adjustable Thermomagnetic Protection for Power Distribution

The ABB TMA trip unit combines thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained overcurrent conditions, while the magnetic element provides rapid tripping when high fault currents occur.

For the 1SDA107582R1, the thermal setting can be adjusted from approximately 441 to 630 A, while the instantaneous magnetic trip threshold can be set between 3150 and 6300 A. This makes the breaker suitable for high-current distribution applications where adjustable protection and a fully rated neutral are required.

Typical Applications

  • Industrial low-voltage main and sub-distribution switchboards.
  • Commercial building electrical distribution systems.
  • Four-wire three-phase distribution circuits.
  • Installations with significant neutral conductor loading.
  • Manufacturing and process-industry power distribution.
  • Applications requiring a fixed 630 A MCCB with adjustable thermomagnetic protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
ABB order code 1SDA107582R1
Alternate catalogue number XT6SE4630BFF000XXX
EAN / GTIN 8015644102357
Product type Moulded-case circuit breaker (MCCB)
Frame XT6
Performance level XT6S
Frame rated current 800 A
Rated current (In) 630 A
Number of poles 4
Neutral rating 100% of rated current
Mounting configuration Fixed
Terminal arrangement Front terminals
Trip unit TMA
Trip unit technology Thermomagnetic
Thermal protection setting (I1) 0.7–1 × In, approximately 441–630 A
Instantaneous protection setting (I3) 3150–6300 A
Ultimate breaking capacity (Icu) at 415 V AC 50 kA
Reference standard IEC 60947-2
Certification IEC

Frequently Asked Questions

What is the ABB 1SDA107582R1 used for?

The ABB 1SDA107582R1 is a 630 A four-pole moulded-case circuit breaker used to provide overload and short-circuit protection in low-voltage power distribution systems.

What protection does the ABB 1SDA107582R1 provide?

The breaker uses a TMA thermomagnetic trip unit providing adjustable thermal overload protection and instantaneous magnetic short-circuit protection.

What is the protection adjustment range?

The thermal protection setting is adjustable from approximately 441 to 630 A, while the instantaneous magnetic trip setting is adjustable from 3150 to 6300 A.

What does InN=100%In mean on the ABB 1SDA107582R1?

It means the neutral pole is fully rated at 100% of the circuit breaker's 630 A phase rated current, rather than being reduced relative to the phase poles.

What is the breaking capacity of the ABB 1SDA107582R1?

The XT6S performance level provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

Trusted ABB SACE Tmax XT Circuit Protection

ABB SACE Tmax XT moulded-case circuit breakers combine compact construction, configurable protection and high short-circuit performance for reliable low-voltage distribution across industrial, commercial and infrastructure applications.