1SDA102853R1 ABB XT6H 800 TMA 800 A 3-Pole Moulded Case Circuit Breaker

1SDA102853R1 ABB XT6H 800 TMA 800 A 3-Pole Moulded Case Circuit Breaker

ABB 1SDA102853R1 is an XT6H 800 three-pole fixed moulded case circuit breaker with an 800 A TMA thermomagnetic trip unit, front terminals and a 65 kA interruption rating at 480 V AC for UL low-voltage power distribution applications.

SKU: 1SDA102853R1MPN: 1SDA102853R1
Price
List Price £3,224.80 ex VAT
Your Price (ex VAT) Save 25%
£2,418.60 25% OFF
You save £806.20 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,418.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,418.60

Why Choose the ABB 1SDA102853R1 XT6H 800 Circuit Breaker?

The ABB 1SDA102853R1 is a high-performance 3-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT6 range, designed for dependable protection of low-voltage power distribution systems. Configured as an XT6H 800, it combines an 800 A rated current with an ABB TMA thermomagnetic trip unit for reliable overload and short-circuit protection.

The circuit breaker incorporates a TMA thermomagnetic release, combining thermal overload protection with adjustable magnetic short-circuit protection. The magnetic protection setting I3 is adjustable from 4000–8000 A, allowing the instantaneous protection threshold to be matched to the requirements of the protected distribution circuit.

The 1SDA102853R1 is supplied as a fixed, three-pole circuit breaker with front terminals and is designed for UL applications. Its H interruption performance level provides a short-circuit interrupting rating of 65 kA at 480 V AC, making it suitable for industrial switchboards and power distribution systems where high fault-current interruption capability is required.

Key Advantages

  • High-performance ABB SACE Tmax XT6 moulded case circuit breaker.
  • 800 A rated current for high-current power distribution applications.
  • TMA thermomagnetic trip unit provides overload and short-circuit protection.
  • Adjustable magnetic protection range of 4000–8000 A.
  • 3-pole fixed configuration with front terminals for switchboard integration.
  • H interruption level rated 65 kA at 480 V AC for demanding fault conditions.

Key Features

  • ABB SACE Tmax XT6H 800 circuit breaker.
  • ABB order code 1SDA102853R1.
  • 800 A rated current (In).
  • 800 A frame size.
  • TMA thermomagnetic release.
  • Magnetic trip setting I3 = 4000–8000 A.
  • Three-pole construction.
  • Fixed installation configuration.
  • Front terminals for electrical connection.
  • 65 kA interruption rating at 480 V AC.
  • Designed and certified for UL applications.

Reliable Thermomagnetic Protection for Power Distribution

Moulded case circuit breakers protect electrical distribution systems against excessive current caused by overloads and short circuits. Thermomagnetic protection combines a thermal element for sustained overload conditions with a magnetic element for rapid operation during high short-circuit currents, providing dependable protection without requiring an electronic trip unit.

The TMA thermomagnetic release fitted to the ABB 1SDA102853R1 provides an 800 A current rating together with an adjustable instantaneous magnetic threshold of 4000–8000 A. Combined with the XT6H frame and its 65 kA at 480 V AC interruption capability, this configuration provides robust protection for demanding low-voltage distribution circuits.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Electrical switchboards and distribution panels.
  • High-current feeder circuit protection.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and industrial power systems.
  • UL installations requiring 800 A thermomagnetic circuit protection.

Technical Specifications

Product group T-Max XT 250 Range
Series SACE Tmax XT
ABB order code 1SDA102853R1
Alternate catalogue number XT6HU3800BFF000XXX
Product type Moulded case circuit breaker
Frame size XT6
Performance level H
Rated current (In) 800 A
Frame rating 800 A
Number of poles 3
Trip unit TMA
Release type Thermomagnetic
Magnetic trip setting (I3) 4000–8000 A
Installation version Fixed
Terminal connection Front terminals
Interruption rating 65 kA at 480 V AC
Standard UL
Certification UL
UPC / EAN 8015644033644

Frequently Asked Questions

What is the ABB 1SDA102853R1 used for?

The ABB 1SDA102853R1 is an 800 A moulded case circuit breaker designed to provide overload and short-circuit protection in low-voltage power distribution systems.

What is the rated current of the ABB 1SDA102853R1?

The circuit breaker has a rated current of 800 A and uses the ABB Tmax XT6 800 A frame.

Which trip unit is fitted to this circuit breaker?

The 1SDA102853R1 is fitted with an ABB TMA thermomagnetic trip unit, providing thermal overload protection and magnetic short-circuit protection.

What is the interruption rating of the ABB XT6H 800?

This XT6H configuration has an H interruption performance level rated at 65 kA at 480 V AC.

How is the ABB 1SDA102853R1 installed?

The circuit breaker is supplied as a fixed three-pole unit with front terminals, making it suitable for integration into compatible low-voltage switchboards and electrical distribution panels.

Trusted ABB Protection for Low-Voltage Distribution

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, dependable protection and high interruption performance for industrial, commercial and infrastructure power distribution systems.