ABB 1SDA101957R1 XT4X 160 MA is a 12.5 A 3-pole moulded case circuit breaker with adjustable 62.5–125 A magnetic instantaneous protection for industrial motor circuits.
£1,552.59
The ABB XT4X 160 MA 12.5, order code 1SDA101957R1, is a high-performance 3-pole moulded case circuit breaker (MCCB) for motor protection from the ABB SACE Tmax XT range. Built on the XT4 frame, it combines a 12.5 A rated current with an adjustable instantaneous magnetic protection range of 62.5–125 A, providing effective short-circuit protection for motors and associated industrial circuits.
This breaker uses ABB's MA magnetic-only trip unit, making it particularly suitable for motor circuits where overload protection is provided separately by a motor starter, overload relay or electronic motor protection device. The adjustable instantaneous trip threshold allows the protection characteristic to be coordinated with motor starting currents while maintaining rapid interruption of high fault currents.
The XT4X version is ABB's high breaking-capacity configuration within the XT4 family and is specified as a 200 kA class breaker. This model has three poles, a 160 A frame size and front fixed terminals, providing a robust solution for demanding industrial distribution boards, motor control centres and machinery installations.
Motor circuits require protection capable of distinguishing between normal motor starting current and a genuine short-circuit condition. The ABB XT4X 160 MA uses an adjustable magnetic trip unit, allowing the instantaneous protection threshold to be set between 62.5 A and 125 A so that protection can be coordinated with the characteristics of the connected motor and starter.
Because the MA trip unit provides magnetic short-circuit protection rather than conventional thermal overload protection, the breaker is normally used as part of a coordinated motor protection system incorporating a separate overload relay or motor protection device. The high breaking capability of the XT4X design also makes it particularly suitable for industrial installations with high prospective fault currents.
| Series | SACE Tmax XT |
|---|---|
| ABB order code | 1SDA101957R1 |
| Product type | Moulded case circuit breaker for motor protection |
| Frame | XT4 160 |
| Rated current | 12.5 A |
| Trip unit | MA magnetic-only |
| Instantaneous trip setting (Im) | 62.5–125 A |
| Number of poles | 3 |
| Breaking-capacity version | XT4X, 200 kA class |
| Installation | Fixed |
| Terminal type | Front fixed terminals |
| Application | Motor short-circuit protection |
| EAN | 8056221020015 |
| Weight | 1.4 kg |
The ABB 1SDA101957R1 is an XT4X moulded case circuit breaker designed primarily for short-circuit protection of three-phase motor circuits.
This circuit breaker has a rated current of 12.5 A.
The MA trip unit provides an adjustable instantaneous magnetic trip setting from 62.5 A to 125 A.
The MA trip unit provides magnetic short-circuit protection. Motor overload protection is normally provided by a separate overload relay or motor protection device as part of the coordinated motor starter system.
The 1SDA101957R1 is a 3-pole circuit breaker designed for use in three-phase electrical systems.
ABB SACE Tmax XT moulded case circuit breakers are engineered for dependable circuit protection, compact switchboard integration and effective coordination within industrial motor control and power distribution systems.
We use cookies