ABB 1SDA101954R1 XT4V 160 is a 10 A three-pole fixed SACE Tmax XT motor protection circuit breaker with an MA magnetic trip unit, 50–100 A instantaneous setting range and front terminals.
£1,074.15
The ABB XT4V 160 MA 10 Im=50...100 3p F F, order code 1SDA101954R1, is a high-performance three-pole moulded-case circuit breaker for motor protection from the ABB SACE Tmax XT4 series. Designed for demanding low-voltage motor circuits, it combines the compact XT4 frame with an MA magnetic trip unit and a rated current of 10 A.
The XT4V version provides a high ultimate short-circuit breaking capacity of 150 kA at 400/415 V AC. Its MA trip unit provides adjustable instantaneous magnetic short-circuit protection, with the magnetic threshold adjustable from 50–100 A, making the breaker suitable for coordinated motor-protection systems where overload protection is provided separately.
This model features a fixed three-pole configuration with front terminals for straightforward integration into industrial switchboards and motor-control panels. The combination of high interruption capability, compact construction and adjustable magnetic protection makes the 1SDA101954R1 well suited to motor starters, machinery and industrial automation systems.
Motor-protection circuit breakers with an MA magnetic release are designed primarily to provide short-circuit protection in motor feeders. The adjustable instantaneous magnetic threshold allows the breaker to tolerate normal motor starting currents while rapidly interrupting severe short-circuit currents, with motor overload protection typically provided by a separate thermal or electronic overload relay.
The ABB Tmax XT4V platform combines compact dimensions with high short-circuit interruption performance. With its 10 A rating, 50–100 A adjustable magnetic threshold and 150 kA breaking capacity at 400/415 V AC, the 1SDA101954R1 is suited to coordinated motor starters and demanding industrial motor-control systems.
| Series | SACE Tmax XT4 |
|---|---|
| ABB order code | 1SDA101954R1 |
| Product type | Moulded-case circuit breaker for motor protection |
| Frame size | XT4 160 |
| Breaking-capacity version | XT4V |
| Trip unit | MA magnetic release |
| Rated current | 10 A |
| Instantaneous magnetic trip setting (Im) | 50–100 A |
| Number of poles | 3 |
| Rated voltage | up to 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 150 kA |
| Mounting type | Fixed |
| Terminal arrangement | Front terminals |
| Application | Motor short-circuit protection |
| Standards | IEC |
The ABB 1SDA101954R1 is a three-pole motor protection circuit breaker designed primarily to provide short-circuit protection for low-voltage motor circuits and coordinated motor starters.
This ABB XT4V motor protection circuit breaker has a rated current of 10 A.
The MA magnetic release has an adjustable instantaneous trip setting of 50–100 A.
The XT4V version provides an ultimate short-circuit breaking capacity of 150 kA at 400/415 V AC, making it suitable for installations with high prospective fault currents.
The MA magnetic trip unit is intended primarily for short-circuit protection, so motor overload protection is normally provided by a separate thermal or electronic overload relay as part of the coordinated motor starter.
ABB SACE Tmax XT motor protection circuit breakers are used in industrial machinery and motor-control systems where dependable short-circuit protection, compact installation and high interruption performance are essential.