1SDA101909R1 ABB XT7D 1000 4-Pole Fixed Switch-Disconnector

1SDA101909R1 ABB XT7D 1000 4-Pole Fixed Switch-Disconnector

ABB 1SDA101909R1 is a 1000 A four-pole SACE Tmax XT7D fixed switch-disconnector with front terminals and a lever operating mechanism for high-current low-voltage switching and isolation.

SKU: 1SDA101909R1MPN: 1SDA101909R1
Price
List Price £3,006.13 ex VAT
Your Price (ex VAT) Save 25%
£2,254.60 25% OFF
You save £751.53 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,254.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,254.60

Why Choose the ABB XT7D 1000 1SDA101909R1 Switch-Disconnector?

The ABB 1SDA101909R1 is a SACE Tmax XT7D 1000 switch-disconnector designed for dependable switching and isolation of high-current low-voltage circuits. Rated at 1000 A, this four-pole device combines the robust ABB Tmax XT7 platform with a fixed installation format, front terminals and a lever operating mechanism for straightforward integration into power-distribution assemblies.

Configured as a moulded case switch / switch-disconnector, the XT7D is intended primarily for circuit switching and isolation rather than overload and short-circuit protection through an integrated trip release. It is therefore well suited to installations where the required overcurrent protection is provided by separate protective devices elsewhere in the electrical system.

The 1SDA101909R1 carries 1000 A in both AC-22A and AC-23A utilisation categories at 415/440 V AC and 690 V AC. A rated short-time withstand current of 20 kA, rated insulation voltage of 1000 V and rated impulse withstand voltage of 8 kV make it a robust isolation solution for demanding industrial and infrastructure power-distribution applications.

Key Advantages

  • High-current 1000 A switch-disconnector for demanding low-voltage installations.
  • Provides reliable switching and circuit isolation in main and sub-distribution systems.
  • Four-pole construction supports switching of three-phase circuits including the neutral conductor.
  • Rated at 1000 A for AC-22A and AC-23A duty at both 415/440 V AC and 690 V AC.
  • 20 kA rated short-time withstand current supports demanding high-current distribution applications.
  • Fixed installation with front terminals provides practical switchboard integration.

Key Features

  • ABB SACE Tmax XT7D series.
  • 1000 A rated uninterrupted current.
  • 4-pole construction.
  • Switch-disconnector / moulded case switch configuration.
  • Fixed installation.
  • Front main-circuit terminals.
  • Lever operating mechanism.
  • Rated operational voltage up to 690 V AC and 750 V DC.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 8 kV.
  • Rated short-time withstand current of 20 kA.
  • Optional motor drive capability.

Reliable High-Current Switching and Isolation

The ABB XT7D 1000 provides a dedicated solution for installations requiring dependable high-current switching and isolation without an integrated overload or short-circuit protection release. Its 1000 A AC-22A and AC-23A ratings support demanding distribution duties, while the four-pole arrangement enables simultaneous switching within three-phase systems incorporating a neutral conductor.

With its 20 kA short-time withstand current, 1000 V insulation rating, fixed construction and front bolt connections, the 1SDA101909R1 is engineered for integration into substantial low-voltage switchboards. Optional motorised operation further allows the XT7D platform to be adapted for applications requiring remote or automated switching.

Typical Applications

  • Main switch and isolation duties in low-voltage switchboards.
  • Industrial power-distribution systems.
  • Main distribution boards and sub-distribution assemblies.
  • Transformer and generator distribution circuits.
  • Manufacturing and process-industry installations.
  • Commercial buildings and critical infrastructure.
  • High-current circuits where overcurrent protection is provided separately.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101909R1
Product type Switch-disconnector / moulded case switch
Frame size XT7
Rated uninterrupted current (Iu) 1000 A
Number of poles 4
AC-22A rated operational current at 415/440 V AC 1000 A
AC-22A rated operational current at 690 V AC 1000 A
AC-23A rated operational current at 415/440 V AC 1000 A
AC-23A rated operational current at 690 V AC 1000 A
DC-22A / DC-23A rated current at 250 V DC 1000 A with 2 poles in series
DC-22A / DC-23A rated current at 500 V DC 1000 A with 3 poles in series
DC-22A / DC-23A rated current at 750 V DC 1000 A with 4 poles in series
Rated operational voltage Up to 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated short-time withstand current (Icw) 20 kA
Installation Fixed
Terminal connection Front
Main-circuit connection Bolt connection
Operating mechanism Lever
Motor drive Optional
Degree of protection, front IP20
Electrical durability 3000 cycles
Mechanical durability 10000 cycles
Product dimensions (W × H × D) 280 × 268 × 166 mm
Product net weight 12.5 kg
Standard IEC 60947-2
EAN / GTIN 8056221019538

Frequently Asked Questions

What is the ABB 1SDA101909R1?

The ABB 1SDA101909R1 is a 1000 A four-pole SACE Tmax XT7D switch-disconnector designed for dependable switching and isolation of high-current low-voltage electrical circuits.

Is the ABB XT7D 1000 a protective circuit breaker?

The XT7D is configured as a moulded case switch / switch-disconnector rather than a circuit breaker with an integrated overload and short-circuit trip release. Appropriate separate overcurrent protection should therefore be provided where required by the electrical installation.

What is the rated current of the ABB 1SDA101909R1?

The 1SDA101909R1 has a rated uninterrupted current of 1000 A and is rated for 1000 A AC-22A and AC-23A operation at both 415/440 V AC and 690 V AC.

How is the ABB 1SDA101909R1 configured?

The device is supplied in a fixed four-pole configuration with front terminals and a lever operating mechanism.

What is the short-time withstand current of the ABB XT7D 1000?

The ABB XT7D 1000 has a rated short-time withstand current of 20 kA, supporting use in demanding high-current electrical distribution systems.

Trusted Switching and Isolation from ABB

ABB SACE Tmax XT switch-disconnectors combine dependable high-current switching, robust isolation performance and flexible installation options to provide reliable control of industrial, commercial and infrastructure power-distribution circuits.