1SDA101811R1 ABB XT7L M 1000 Ekip G Hi-Touch LSIG 1000 A 4-Pole Circuit Breaker

1SDA101811R1 ABB XT7L M 1000 Ekip G Hi-Touch LSIG 1000 A 4-Pole Circuit Breaker

ABB 1SDA101811R1 is an XT7L M 1000 four-pole fixed moulded case circuit breaker rated at 1000 A with front terminals and Ekip G Hi-Touch LSIG electronic protection for generator and low-voltage distribution applications.

SKU: 1SDA101811R1MPN: 1SDA101811R1
Price
List Price £14,893.00 ex VAT
Your Price (ex VAT) Save 25%
£11,169.75 25% OFF
You save £3,723.25 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,169.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,169.75

Why Choose the ABB XT7L M 1000 Ekip G Hi-Touch LSIG Circuit Breaker?

The ABB XT7L M 1000 Ekip G Hi-Touch LSIG, order code 1SDA101811R1, is a high-performance SACE Tmax XT moulded case circuit breaker designed for advanced generator and low-voltage power-system protection. This four-pole breaker has a rated uninterrupted current of 1000 A and combines the XT7L high-breaking-capacity platform with ABB's sophisticated Ekip G Hi-Touch LSIG electronic release.

The Ekip G Hi-Touch LSIG solid-state electronic trip unit provides long-time, short-time, instantaneous and earth-fault protection functions. The generator-oriented Ekip G platform makes this configuration particularly suitable for generating sets and associated distribution systems requiring configurable electronic protection and effective fault coordination.

The 1SDA101811R1 is supplied as a four-pole fixed circuit breaker with front terminals. Its XT7L performance level, 1000 A rating and advanced LSIG protection make it a robust solution for generator switchboards, industrial power distribution and critical installations with demanding protection requirements.

Key Advantages

  • High-current 1000 A generator and distribution protection from the ABB SACE Tmax XT range.
  • Advanced Ekip G Hi-Touch LSIG solid-state electronic protection technology.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • Generator-oriented Ekip G platform for generating-set and associated distribution applications.
  • Four-pole configuration for comprehensive circuit switching and protection.
  • XT7L high-breaking-capacity performance level for demanding low-voltage systems.
  • Fixed mounting with front terminals for integration into compatible switchboards.

Key Features

  • ABB SACE Tmax XT series.
  • XT7L M 1000 circuit breaker configuration.
  • 1000 A rated uninterrupted current.
  • 1000 A trip-unit rated current.
  • 4-pole construction.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • Generator-oriented electronic protection platform.
  • Overload adjustment range of 400–1000 A.
  • Rated voltage of 690 V.
  • Fixed installation configuration.
  • Front terminals.
  • Bolted main-circuit connection.

Advanced Generator and High-Current Distribution Protection

Generator-fed electrical systems can require protection characteristics tailored to the operating and fault-current behaviour of generating equipment. ABB's Ekip G Hi-Touch platform provides advanced electronic protection suitable for generator applications, helping protect generating sources, feeders, switchgear and connected distribution circuits against abnormal current conditions.

The LSIG configuration combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection. Together with the 1000 A rating, four-pole construction and XT7L high-performance platform, the 1SDA101811R1 provides comprehensive protection for critical generator and high-current low-voltage distribution assemblies.

Typical Applications

  • Generator protection switchboards.
  • Standby and emergency generation systems.
  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • Manufacturing and process plant power systems.
  • Infrastructure and critical power distribution.
  • High-current feeder protection and isolation.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101811R1
EAN 8056221018555
Product type Moulded case circuit breaker
Frame / configuration XT7L M
Rated uninterrupted current (Iu) 1000 A
Trip unit rated current (In) 1000 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic release
Protection functions Long-time, short-time, instantaneous and earth-fault
Overload release adjustment range 400–1000 A
Rated voltage 690 V
Performance level XT7L
Mounting configuration Fixed
Terminal arrangement Front terminals
Main-circuit connection Bolted connection

Frequently Asked Questions

What is the ABB 1SDA101811R1?

The ABB 1SDA101811R1 is an XT7L M 1000 SACE Tmax XT moulded case circuit breaker rated at 1000 A, with four poles, fixed mounting, front terminals and an Ekip G Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG release provide?

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection functions.

Is the ABB 1SDA101811R1 suitable for generator protection?

Yes. The Ekip G Hi-Touch platform is intended for advanced generator protection applications, making this breaker suitable for generator switchboards and associated low-voltage distribution systems.

What is the rated current of the ABB XT7L M 1000 1SDA101811R1?

The ABB 1SDA101811R1 has a rated uninterrupted current and trip-unit rated current of 1000 A.

What is the overload adjustment range of the ABB 1SDA101811R1?

The Ekip G Hi-Touch trip unit provides an overload release adjustment range of 400–1000 A.

Does the ABB 1SDA101811R1 provide earth-fault protection?

Yes. The LSIG configuration includes earth-fault protection in addition to long-time, short-time and instantaneous protection functions.

What mounting and terminal configuration does the ABB 1SDA101811R1 use?

The breaker is supplied in a fixed four-pole configuration with front terminals and uses a bolted main-circuit connection.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in industrial, commercial, infrastructure and power-generation applications where dependable high-current protection, advanced electronic trip technology and robust short-circuit performance are required.