1SDA101805R1 ABB XT7L M 1600 Ekip G Dip LS/I 1600A 4P Circuit Breaker

1SDA101805R1 ABB XT7L M 1600 Ekip G Dip LS/I 1600A 4P Circuit Breaker

ABB 1SDA101805R1 XT7L M 1600 is a 1600 A four-pole fixed moulded case circuit breaker with an Ekip G Dip LS/I solid-state electronic trip unit, front terminals and a stored-energy operating mechanism for demanding generator and low-voltage power-distribution protection.

SKU: 1SDA101805R1MPN: 1SDA101805R1
Price
List Price £9,925.16 ex VAT
Your Price (ex VAT) Save 25%
£7,443.87 25% OFF
You save £2,481.29 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,443.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,443.87

Why Choose the ABB XT7L M 1600 Ekip G Dip LS/I 1SDA101805R1 Circuit Breaker?

The ABB 1SDA101805R1 is a high-performance SACE Tmax XT7L M moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power systems. This fixed four-pole circuit breaker combines a 1600 A rated current with ABB’s Ekip G Dip LS/I solid-state electronic trip unit, providing dependable overload and short-circuit protection for generator and power-distribution applications.

As part of the ABB SACE Tmax XT range, the XT7L M 1600 is engineered for high-current installations requiring robust interruption performance and electronic protection. The Ekip G Dip LS/I release provides long-time, short-time and instantaneous protection functions, while its generator-oriented Ekip G configuration makes it particularly suitable for power-generation systems and associated distribution circuits.

The 1SDA101805R1 features a four-pole fixed configuration with front terminals, an XT7M frame and a stored-energy operating mechanism. Its XT7L configuration carries ABB’s L interruption rating, providing a robust solution for main distribution boards, generator circuits and high-current feeders where significant prospective short-circuit currents may occur.

Key Advantages

  • High-performance 1600 A moulded case circuit breaker for demanding low-voltage power systems.
  • Ekip G Dip LS/I electronic trip unit designed for generator and power-distribution protection.
  • Long-time, short-time and instantaneous protection functions.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • XT7L L interruption rating for demanding high-current electrical installations.
  • Fixed construction with front terminals for integration into switchboards and distribution assemblies.
  • Stored-energy operating mechanism supports dependable circuit-breaker operation.
  • Solid-state electronic release technology provides consistent monitoring and fault response.
  • ABB SACE Tmax XT platform is designed for demanding industrial, infrastructure and power-generation applications.

Key Features

  • ABB SACE Tmax XT7L M moulded case circuit breaker.
  • 1600 A rated current.
  • Four-pole fixed configuration.
  • XT7M frame size.
  • Ekip G Dip LS/I solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Generator-oriented Ekip G protection platform.
  • L interruption-performance rating.
  • Front main-circuit terminals.
  • Stored-energy operating mechanism.
  • Designed to IEC requirements.
  • Suitable for high-current AC power-distribution systems.

Generator and High-Current Power Distribution Protection

The ABB Tmax XT7L M platform is engineered for high-current electrical systems where dependable fault interruption and electronic protection are essential. With its 1600 A rated current, four-pole construction and XT7L L interruption rating, the 1SDA101805R1 provides a robust protective solution for generator circuits, incoming supplies and major distribution feeders.

The Ekip G Dip LS/I solid-state trip unit provides long-time, short-time and instantaneous protection functions. This combination protects against sustained overloads and different levels of short-circuit current while supporting coordinated protection strategies in generator, industrial and infrastructure power-distribution systems.

Typical Applications

  • Generator protection and generator distribution systems.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • High-current incoming supply protection.
  • Major feeder circuits.
  • Manufacturing plants and process facilities.
  • Infrastructure and critical-power installations.
  • Three-phase systems requiring four-pole switching and electronic LS/I protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101805R1
GTIN / EAN 8056221018494
Product type Moulded case circuit breaker
Frame size XT7M
Performance level XT7L
Rated current 1600 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous
Interruption rating L
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Stored energy
Standard IEC
Product weight 15.5 kg
Country of origin Italy
Application Generator and low-voltage power-distribution protection

Frequently Asked Questions

What is the ABB 1SDA101805R1 used for?

The ABB 1SDA101805R1 is a 1600 A four-pole moulded case circuit breaker designed for protection and switching in demanding generator and low-voltage power-distribution applications.

What trip unit is fitted to the ABB 1SDA101805R1?

The breaker is fitted with an Ekip G Dip LS/I solid-state electronic trip unit, providing long-time, short-time and instantaneous protection functions.

What does LS/I mean on the ABB 1SDA101805R1?

LS/I identifies the principal protection functions provided by the trip unit: long-time (L), short-time (S) and instantaneous (I) protection. This configuration protects against overload and short-circuit conditions and does not include the ground-fault protection function found on LSIG versions.

What is the interruption rating of the ABB XT7L M 1600?

The 1SDA101805R1 uses ABB’s XT7L performance level with an L interruption rating, designed for demanding low-voltage power-distribution and generator applications.

How is the ABB XT7L M 1600 1SDA101805R1 installed?

The 1SDA101805R1 is a fixed four-pole circuit breaker with front terminals and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and power-distribution assemblies.

Trusted for Generator and Power Distribution Protection

ABB SACE Tmax XT circuit breakers combine robust interruption performance with Ekip electronic protection technology, providing dependable protection for generators, industrial switchboards, major feeders and critical low-voltage power-distribution systems.