1SDA101804R1 ABB XT7L M 1250 Ekip G Dip LS/I 1250A 4P Circuit Breaker

1SDA101804R1 ABB XT7L M 1250 Ekip G Dip LS/I 1250A 4P Circuit Breaker

ABB 1SDA101804R1 XT7L M 1250 is a 1250 A four-pole fixed moulded case circuit breaker with an Ekip G Dip LS/I solid-state electronic trip unit, front terminals and stored-energy operating mechanism for demanding generator and low-voltage power-distribution protection.

SKU: 1SDA101804R1MPN: 1SDA101804R1
Price
List Price £8,418.09 ex VAT
Your Price (ex VAT) Save 25%
£6,313.57 25% OFF
You save £2,104.52 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,313.57
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,313.57

Why Choose the ABB XT7L M 1250 Ekip G Dip LS/I 1SDA101804R1 Circuit Breaker?

The ABB 1SDA101804R1 is a high-performance SACE Tmax XT7L M moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power systems. This fixed four-pole circuit breaker combines a 1250 A rated current with ABB’s Ekip G Dip LS/I solid-state electronic trip unit, providing overload and short-circuit protection for generator and power-distribution applications.

As part of the ABB SACE Tmax XT range, the XT7L M 1250 is engineered for installations requiring high interruption performance and dependable electronic protection. The Ekip G Dip LS/I release provides long-time, short-time and instantaneous protection functions, while its generator-oriented Ekip G configuration makes it suitable for power-generation and associated distribution circuits.

The 1SDA101804R1 features a four-pole fixed configuration with front terminals, an XT7M frame and a stored-energy operating mechanism. Its XT7L performance level belongs to ABB’s 120 kA interruption class, providing robust protection for high-current installations where substantial prospective short-circuit currents may occur.

Key Advantages

  • High-performance 1250 A moulded case circuit breaker for demanding low-voltage power systems.
  • Ekip G Dip LS/I electronic trip unit designed for generator and power-distribution protection.
  • Long-time, short-time and instantaneous protection functions.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • XT7L 120 kA interruption class for systems with high prospective fault currents.
  • Fixed construction with front terminals for integration into switchboards and distribution assemblies.
  • Stored-energy operating mechanism supports dependable breaker operation.
  • Solid-state electronic protection provides consistent circuit monitoring and fault response.
  • ABB SACE Tmax XT platform supports demanding industrial and infrastructure power-distribution applications.

Key Features

  • ABB SACE Tmax XT7L M moulded case circuit breaker.
  • 1250 A rated current.
  • Four-pole fixed configuration.
  • XT7M frame size.
  • Ekip G Dip LS/I solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Generator-oriented Ekip G protection platform.
  • L interruption-performance level.
  • 120 kA interruption class.
  • Front main-circuit terminals.
  • Stored-energy operating mechanism.
  • Designed to IEC requirements.
  • Suitable for high-current AC power-distribution systems.

Generator and High-Current Power Distribution Protection

The ABB Tmax XT7L M platform is engineered for high-current electrical systems where dependable fault interruption is essential. With its 1250 A rated current and XT7L 120 kA interruption class, the 1SDA101804R1 provides a robust protective solution for generator circuits, incoming supplies and major distribution feeders exposed to significant prospective short-circuit currents.

The Ekip G Dip LS/I solid-state trip unit provides long-time, short-time and instantaneous protection functions. This combination protects against sustained overloads and different levels of short-circuit current while supporting coordinated protection strategies in generator and industrial power-distribution systems.

Typical Applications

  • Generator protection and generator distribution systems.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • High-current incoming supply protection.
  • Major feeder circuits.
  • Manufacturing plants and process facilities.
  • Infrastructure and critical-power installations.
  • Three-phase systems requiring four-pole switching and electronic LS/I protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101804R1
GTIN / EAN 8056221018487
Product type Moulded case circuit breaker
Frame size XT7M
Performance level XT7L
Rated current 1250 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous
Interruption rating L
Interruption class 120 kA
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Stored energy
Standard IEC
Product weight 15.5 kg
Country of origin Italy
Application Generator and low-voltage power-distribution protection

Frequently Asked Questions

What is the ABB 1SDA101804R1 used for?

The ABB 1SDA101804R1 is a 1250 A four-pole moulded case circuit breaker designed for protection and switching in demanding generator and low-voltage power-distribution applications.

What trip unit is fitted to the ABB 1SDA101804R1?

The breaker is fitted with an Ekip G Dip LS/I solid-state electronic trip unit, providing long-time, short-time and instantaneous protection functions.

What does LS/I mean on the ABB 1SDA101804R1?

LS/I identifies the principal protection functions provided by the trip unit: long-time (L), short-time (S) and instantaneous (I) protection. This configuration protects against overload and short-circuit conditions without an LSIG ground-fault protection function.

What is the interruption performance of the ABB XT7L M 1250?

The 1SDA101804R1 uses ABB’s XT7L performance level, identified by an L interruption rating and belonging to the 120 kA interruption class for demanding low-voltage power systems.

How is the ABB XT7L M 1250 1SDA101804R1 installed?

The 1SDA101804R1 is a fixed four-pole circuit breaker with front terminals and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and power-distribution assemblies.

Trusted for Generator and Power Distribution Protection

ABB SACE Tmax XT circuit breakers combine high short-circuit interruption performance with Ekip electronic protection technology, providing dependable protection for generators, industrial switchboards, major feeders and critical low-voltage power-distribution systems.