1SDA101794R1 ABB XT7L M 800 Ekip Hi-Touch LSI 800A 4-Pole Circuit Breaker

1SDA101794R1 ABB XT7L M 800 Ekip Hi-Touch LSI 800A 4-Pole Circuit Breaker

ABB 1SDA101794R1 is an 800 A four-pole SACE Tmax XT7L M fixed moulded case circuit breaker with front terminals, stored-energy operation and an Ekip Hi-Touch LSI electronic protection release.

SKU: 1SDA101794R1MPN: 1SDA101794R1
Price
List Price £9,923.22 ex VAT
Your Price (ex VAT) Save 25%
£7,442.42 25% OFF
You save £2,480.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,442.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,442.42

Why Choose the ABB XT7L M 800 Ekip Hi-Touch LSI 1SDA101794R1 Circuit Breaker?

The ABB 1SDA101794R1 is a high-performance SACE Tmax XT7L M moulded case circuit breaker designed for advanced protection, switching and isolation in demanding low-voltage power distribution systems. Rated at 800 A, this four-pole fixed circuit breaker combines ABB's high-breaking-capacity XT7L M platform with an advanced Ekip Hi-Touch LSI solid-state electronic protection release.

The Ekip Hi-Touch LSI trip unit provides long-time, short-time and instantaneous protection against overload and short-circuit conditions. Its configurable electronic settings include an overload adjustment range of 320–800 A, short-time delayed short-circuit adjustment from 480–8000 A and instantaneous short-circuit adjustment from 1200–12000 A, supporting effective protection coordination across demanding electrical networks.

The XT7L M version provides an ultimate short-circuit breaking capacity of 120 kA at 400 V AC. The 1SDA101794R1 is supplied as a four-pole fixed circuit breaker with front terminals and incorporates stored-energy and lever operating mechanisms, providing a robust solution for industrial switchboards, main distribution assemblies and critical infrastructure.

Key Advantages

  • High-current 800 A moulded case circuit breaker for demanding low-voltage distribution systems.
  • Advanced Ekip Hi-Touch LSI electronic trip unit with configurable protection settings.
  • Provides long-time, short-time and instantaneous protection.
  • 120 kA ultimate short-circuit breaking capacity at 400 V AC for high fault-current installations.
  • Four-pole fixed construction with front terminals for switchboard integration.
  • Optional motor-drive capability supports remotely operated and automated power-distribution systems.

Key Features

  • ABB SACE Tmax XT7L M series.
  • 800 A rated uninterrupted current.
  • 4-pole construction.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 320–800 A overload adjustment range.
  • 480–8000 A short-time delayed short-circuit adjustment range.
  • 1200–12000 A instantaneous short-circuit adjustment range.
  • 120 kA Icu at 400 V AC.
  • 690 V rated voltage.

Advanced Hi-Touch LSI Protection for High-Current Distribution

Moulded case circuit breakers such as the ABB Tmax XT7L M protect electrical installations against overload and short-circuit conditions while providing dependable switching and isolation. The Ekip Hi-Touch electronic release provides advanced configurable protection, allowing operating thresholds to be matched to the electrical network and supporting effective coordination between upstream and downstream protective devices.

With its 800 A current rating, 120 kA breaking capacity at 400 V AC and adjustable LSI protection, the 1SDA101794R1 is suited to demanding systems where robust fault interruption and precise electronic protection are required. Its four-pole fixed construction, front terminals, stored-energy mechanism and optional motor-drive capability support integration into sophisticated industrial and infrastructure switchboards.

Typical Applications

  • Industrial low-voltage switchboards and main distribution boards.
  • Main incoming and outgoing feeder protection.
  • Transformer, generator and plant protection systems.
  • Manufacturing and process-industry electrical installations.
  • Commercial buildings and critical infrastructure distribution.
  • High-fault-level networks requiring advanced electronic short-circuit protection.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101794R1
Product type Moulded case circuit breaker
Frame size XT7M
Breaking-capacity version XT7L
Rated uninterrupted current 800 A
Number of poles 4
Trip unit Ekip Hi-Touch LSI
Release technology Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Ultimate short-circuit breaking capacity at 400 V AC 120 kA
Rated voltage 690 V
Rated voltage range 220–690 V
Overload protection adjustment 320–800 A
Short-time delayed short-circuit adjustment 480–8000 A
Instantaneous short-circuit adjustment 1200–12000 A
Integrated earth-fault protection No
Installation Fixed
Terminals Front terminals
Main-circuit connection Bolt connection
Operating mechanism Stored energy with lever operating mechanism
Motor drive Optional
Degree of protection IP20
Power loss 24 W
Standard IEC
EAN / GTIN 8056221018388

Frequently Asked Questions

What is the ABB 1SDA101794R1 used for?

The ABB 1SDA101794R1 is an 800 A four-pole moulded case circuit breaker designed for advanced protection, switching and isolation in demanding low-voltage power distribution systems.

What protection unit is fitted to the ABB 1SDA101794R1?

The breaker is fitted with an Ekip Hi-Touch LSI solid-state electronic release providing long-time, short-time and instantaneous protection.

What is the breaking capacity of the ABB XT7L M 800?

The XT7L M 800 provides an ultimate short-circuit breaking capacity of 120 kA at 400 V AC, making it suitable for installations with high prospective fault currents.

What protection adjustment ranges does the ABB 1SDA101794R1 provide?

The Ekip Hi-Touch LSI release provides an overload adjustment range of 320–800 A, short-time delayed short-circuit adjustment of 480–8000 A and instantaneous short-circuit adjustment of 1200–12000 A.

Can the ABB 1SDA101794R1 be motorised?

Yes. The XT7L M platform supports an optional motor drive, enabling integration into remotely controlled and automated switchboard systems.

Trusted Advanced Circuit Protection from ABB

ABB SACE Tmax XT circuit breakers combine advanced electronic protection, high short-circuit performance and flexible operating capabilities to provide dependable protection for demanding industrial, commercial and infrastructure power-distribution systems.