1SDA101785R1 ABB XT7L M 1600 Ekip Touch LSIG 4P Circuit Breaker

1SDA101785R1 ABB XT7L M 1600 Ekip Touch LSIG 4P Circuit Breaker

ABB 1SDA101785R1 XT7L M 1600 is a 1600 A four-pole fixed moulded-case circuit breaker with an Ekip Touch LSIG electronic trip unit and 120 kA breaking capacity at 380/415 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA101785R1MPN: 1SDA101785R1
Price
List Price £12,889.31 ex VAT
Your Price (ex VAT) Save 25%
£9,666.98 25% OFF
You save £3,222.33 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,666.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,666.98

Why Choose the ABB XT7L M 1600 Ekip Touch LSIG 1SDA101785R1 Circuit Breaker?

The ABB 1SDA101785R1 is a high-performance SACE Tmax XT7L M moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 1600 A, this four-pole circuit breaker combines ABB's XT7 M platform with an advanced Ekip Touch LSIG electronic trip unit for configurable protection of industrial, commercial and infrastructure electrical installations.

The Ekip Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection, enabling comprehensive protection against overloads, short circuits and earth faults. Its touchscreen-based interface provides intuitive access to protection settings and operating information, supporting effective coordination and selective protection across modern low-voltage distribution networks.

This XT7L M configuration features a 1600 A rated current, four-pole construction, fixed installation and front terminals. The L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 380/415 V AC, making it particularly suitable for high-current switchboards and distribution systems where substantial fault interruption capability is required.

Key Advantages

  • High-performance ABB SACE Tmax XT7L M moulded-case circuit breaker.
  • 1600 A rated current for high-current low-voltage distribution systems.
  • Four-pole configuration for protection and switching of three-phase systems with neutral.
  • Advanced Ekip Touch LSIG electronic trip unit.
  • Configurable long-time, short-time, instantaneous and earth-fault protection functions.
  • 120 kA ultimate breaking capacity at 380/415 V AC.
  • Fixed installation with front terminals for switchboard integration.
  • XT7 M stored-energy operating mechanism for reliable switching performance.

Key Features

  • ABB SACE Tmax XT7L M series.
  • 1600 A rated current.
  • 4-pole circuit breaker.
  • Ekip Touch LSIG electronic protection release.
  • LSIG protection functions for overload, selective short circuit, instantaneous short circuit and earth fault.
  • L short-circuit performance level.
  • 120 kA Icu at 380/415 V AC.
  • Fixed mounting arrangement.
  • Front electrical terminals.
  • Stored-energy operating mechanism.
  • Electronic protection designed for demanding low-voltage power distribution applications.

Advanced Protection for Low-Voltage Power Distribution

Moulded-case circuit breakers such as the ABB Tmax XT7 protect electrical distribution systems by automatically interrupting current when abnormal conditions occur. The 1SDA101785R1 combines the high-current XT7L M circuit-breaker platform with ABB's Ekip Touch electronic protection technology, providing configurable protection for demanding power distribution applications.

The Ekip Touch LSIG trip unit supports protection against overload, delayed short-circuit, instantaneous short-circuit and earth-fault conditions. Combined with the XT7L M's 120 kA breaking capacity at 380/415 V AC, this makes the breaker particularly suitable for main and feeder protection in industrial switchboards, commercial distribution equipment and infrastructure applications where high prospective fault currents may be present.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • High-current main and feeder protection.
  • Transformer secondary distribution systems.
  • Motor control centres and industrial switchgear.
  • Distribution systems requiring configurable LSIG protection.
  • Electrical installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT
Frame XT7 M
ABB order code 1SDA101785R1
Product type Moulded-case circuit breaker (MCCB)
Rated current (In) 1600 A
Number of poles 4
Current type AC
Trip unit Ekip Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Short-circuit performance level L
Ultimate breaking capacity (Icu) at 380/415 V AC 120 kA
Installation Fixed
Terminal arrangement Front terminals
Operating mechanism Stored-energy operating mechanism
Application Low-voltage AC electrical distribution

Frequently Asked Questions

What is the ABB 1SDA101785R1 used for?

The ABB 1SDA101785R1 is a 1600 A four-pole moulded-case circuit breaker designed to protect and switch high-current low-voltage electrical distribution systems.

What protection functions does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection, providing comprehensive electronic protection against overloads, short circuits and earth faults.

What is the rated current of the ABB 1SDA101785R1?

The circuit breaker has a rated current of 1600 A.

What is the breaking capacity of the XT7L M 1600?

The XT7L M has an ultimate short-circuit breaking capacity of 120 kA at 380/415 V AC, making it suitable for electrical distribution systems with high prospective fault currents.

How is the ABB 1SDA101785R1 installed?

This model is a fixed four-pole circuit breaker with front terminals, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted Protection from ABB