1SDA101753R1 ABB XT7H M 1600 Ekip G Touch LSIG 1600A 4-Pole Circuit Breaker

1SDA101753R1 ABB XT7H M 1600 Ekip G Touch LSIG 1600A 4-Pole Circuit Breaker

ABB 1SDA101753R1 is a 1600 A four-pole SACE Tmax XT7H M fixed moulded case circuit breaker with front terminals and an Ekip G Touch LSIG electronic protection release.

SKU: 1SDA101753R1MPN: 1SDA101753R1
Price
List Price £14,823.37 ex VAT
Your Price (ex VAT) Save 25%
£11,117.53 25% OFF
You save £3,705.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,117.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,117.53

Why Choose the ABB XT7H M 1600 Ekip G Touch LSIG 1SDA101753R1 Circuit Breaker?

The ABB 1SDA101753R1 is a high-performance SACE Tmax XT7H M moulded case circuit breaker designed for advanced protection, switching and isolation in demanding low-voltage power distribution systems. Rated at 1600 A, this four-pole fixed circuit breaker combines ABB's XT7 M platform with an advanced Ekip G Touch LSIG electronic protection release.

The Ekip G Touch LSIG trip unit provides long-time, short-time, instantaneous and earth-fault protection, delivering comprehensive electronic protection for high-current distribution and generator applications. Its configurable protection functions help engineers coordinate upstream and downstream devices while supporting reliable operation and continuity of service.

The XT7H M is ABB's 70 kA breaking-capacity class within this configuration. The 1SDA101753R1 is supplied as a four-pole fixed circuit breaker with front terminals and is suitable for systems operating up to 690 V AC, providing a robust solution for industrial, commercial and infrastructure power distribution.

Key Advantages

  • High-current 1600 A moulded case circuit breaker for demanding electrical distribution systems.
  • Advanced Ekip G Touch LSIG electronic protection release.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • 70 kA XT7H breaking-capacity class for installations with high prospective fault currents.
  • Four-pole configuration supports three-phase systems requiring neutral conductor switching.
  • Suitable for demanding power-distribution and generator protection applications.

Key Features

  • ABB SACE Tmax XT7H M series.
  • 1600 A rated uninterrupted current.
  • 4-pole construction.
  • Ekip G Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 70 kA XT7H breaking-capacity class.
  • Fixed installation with front terminals.
  • Operating voltage range up to 690 V AC.
  • XT7 M operating platform for high-current switchboard applications.

Advanced LSIG Protection for Power Distribution and Generator Applications

Moulded case circuit breakers such as the ABB Tmax XT7H M protect electrical installations against overload, short-circuit and earth-fault conditions while providing dependable switching and isolation. Advanced electronic trip technology allows protection characteristics to be configured around the electrical network, helping achieve effective selectivity and coordination between protective devices.

The Ekip G Touch LSIG release combines comprehensive electronic protection with the high-current capabilities of the 1600 A XT7H M platform. With long-time, short-time, instantaneous and earth-fault functions, fixed front-terminal construction and suitability for systems up to 690 V AC, the 1SDA101753R1 is engineered for demanding industrial and generator-related distribution applications.

Typical Applications

  • Generator protection and generator distribution systems.
  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and outgoing feeder protection.
  • High-current transformer distribution circuits.
  • Manufacturing and process-industry electrical installations.
  • Commercial and infrastructure power distribution.
  • High-fault-level systems requiring integrated earth-fault protection.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101753R1
Product type Moulded case circuit breaker
Frame / family XT7 M
Breaking-capacity version XT7H
Breaking-capacity class 70 kA
Rated uninterrupted current 1600 A
Number of poles 4
Trip unit Ekip G Touch LSIG
Release technology Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Rated voltage range 220–690 V AC
Installation Fixed
Terminals Front terminals
Product weight 14 kg
EAN / GTIN 8056221017978

Frequently Asked Questions

What is the ABB 1SDA101753R1 used for?

The ABB 1SDA101753R1 is a 1600 A four-pole moulded case circuit breaker designed for advanced protection, switching and isolation in high-current low-voltage power distribution and generator applications.

What protection unit is fitted to the ABB 1SDA101753R1?

This circuit breaker is fitted with an Ekip G Touch LSIG electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.

What is the rated current of the ABB 1SDA101753R1?

The XT7H M 1600 has a rated uninterrupted current of 1600 A.

What breaking-capacity class does the ABB XT7H M 1600 have?

The XT7H version is ABB's 70 kA breaking-capacity class, intended for demanding electrical systems with high prospective fault currents.

How is the ABB 1SDA101753R1 configured?

The 1SDA101753R1 is a four-pole fixed circuit breaker with front terminals, equipped with an Ekip G Touch LSIG electronic trip unit and rated for operation up to 690 V AC.

Trusted Advanced Protection from ABB

ABB SACE Tmax XT circuit breakers combine advanced electronic protection, high short-circuit performance and robust switching technology to provide dependable protection for demanding industrial, commercial, infrastructure and generator power-distribution systems.