1SDA101748R1 ABB XT7H M 1250 Ekip G Dip LS/I 1250 A 4-Pole Generator Protection Circuit Breaker

1SDA101748R1 ABB XT7H M 1250 Ekip G Dip LS/I 1250 A 4-Pole Generator Protection Circuit Breaker

ABB 1SDA101748R1 is an XT7H M 1250 four-pole fixed moulded case circuit breaker rated at 1250 A with front terminals and an Ekip G Dip LS/I electronic trip unit for generator protection.

SKU: 1SDA101748R1MPN: 1SDA101748R1
Price
List Price £7,026.00 ex VAT
Your Price (ex VAT) Save 25%
£5,269.50 25% OFF
You save £1,756.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,269.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,269.50

Why Choose the ABB XT7H M 1250 Ekip G Dip LS/I Circuit Breaker?

The ABB XT7H M 1250 Ekip G Dip LS/I, order code 1SDA101748R1, is a high-performance SACE Tmax XT moulded case circuit breaker specifically configured for generator protection in demanding low-voltage electrical systems. This four-pole XT7H M breaker combines a rated current of 1250 A with ABB's Ekip G Dip LS/I electronic protection technology.

The Ekip G Dip LS/I trip unit is designed for generator applications and provides adjustable overload and short-circuit protection with time-delay functionality. This enables the breaker to protect generators and associated distribution circuits while accommodating the operating characteristics and protection requirements of generating equipment.

The 1SDA101748R1 is supplied as a four-pole, fixed breaker with front terminals. Its XT7H 70 kA performance class, high-current capability and generator-specific electronic protection make it suitable for generator switchboards, standby power systems and other installations requiring dependable protection of generating sources and their outgoing circuits.

Key Advantages

  • Purpose-designed generator protection circuit breaker from the ABB SACE Tmax XT range.
  • High-current 1250 A rating for substantial generator and distribution applications.
  • Ekip G Dip LS/I electronic trip unit optimised for generator protection.
  • Adjustable overload and short-circuit protection with time delay.
  • Four-pole configuration for applications requiring switching and protection of four conductors.
  • XT7H 70 kA performance class for demanding short-circuit conditions.
  • Fixed mounting with front terminals for integration into low-voltage switchboards.

Key Features

  • ABB SACE Tmax XT series.
  • XT7H M 1250 generator-protection circuit breaker.
  • 1250 A rated uninterrupted current.
  • 1250 A trip-unit rated current.
  • 4-pole construction.
  • Ekip G Dip LS/I electronic protection release.
  • Generator-specific overload and short-circuit protection.
  • Adjustable protection with time-delay functionality.
  • XT7H 70 kA performance class.
  • Fixed installation configuration.
  • Front terminal arrangement.

Dedicated Electronic Protection for Generator Systems

Generator protection presents different requirements from conventional distribution protection because generating sources can have distinctive overload and short-circuit characteristics. ABB's Ekip G protection technology is designed for generator applications, enabling appropriate protection of the generating source and associated electrical circuits while supporting coordinated operation within the wider low-voltage system.

The Ekip G Dip LS/I release provides adjustable overload and short-circuit protection with time-delay functionality. Combined with the 1250 A rating, four-pole construction and XT7H high-performance breaker platform, the 1SDA101748R1 provides a robust solution for generator switchboards, standby generation and distributed power applications.

Typical Applications

  • Generator protection switchboards.
  • Standby and emergency generator systems.
  • Industrial generating installations.
  • Commercial building standby power systems.
  • Distributed generation systems.
  • Generator feeder protection and isolation.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101748R1
Product type Moulded case circuit breaker for generator protection
Frame / configuration XT7H M
Performance level XT7H
Rated uninterrupted current (Iu) 1250 A
Trip unit rated current (In) 1250 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Protection application Generator protection
Protection functions Overload and short-circuit protection with time delay
Release type Electronic
Performance class 70 kA
Mounting configuration Fixed
Terminal arrangement Front terminals

Frequently Asked Questions

What is the ABB 1SDA101748R1?

The ABB 1SDA101748R1 is an XT7H M 1250 SACE Tmax XT moulded case circuit breaker for generator protection, rated at 1250 A and supplied with four poles, fixed mounting, front terminals and an Ekip G Dip LS/I electronic trip unit.

What is the Ekip G Dip LS/I trip unit designed for?

The Ekip G Dip LS/I is designed for generator protection and provides adjustable overload and short-circuit protection with time-delay functionality.

What is the rated current of the ABB XT7H M 1250 1SDA101748R1?

The breaker has a rated uninterrupted current and trip-unit rated current of 1250 A.

What is the performance class of the ABB XT7H M 1250?

The 1SDA101748R1 belongs to ABB's XT7H 70 kA performance class, providing high short-circuit performance for demanding generator and distribution applications.

How many poles does the ABB 1SDA101748R1 have?

The ABB 1SDA101748R1 is a four-pole circuit breaker, suitable for generator systems requiring four-pole switching and protection.

Is the ABB 1SDA101748R1 fixed or withdrawable?

This model is supplied in a fixed configuration with front terminals for installation in compatible low-voltage generator and distribution switchboards.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely specified in industrial, commercial, infrastructure and power-generation applications where dependable high-current protection, advanced electronic releases and robust short-circuit performance are required.