1SDA101730R1 ABB XT7H M 800 Ekip Touch Measuring LSI 800A 4-Pole MCCB

1SDA101730R1 ABB XT7H M 800 Ekip Touch Measuring LSI 800A 4-Pole MCCB

ABB 1SDA101730R1 XT7H M 800 is an 800 A four-pole fixed moulded case circuit breaker with Ekip Touch Measuring LSI electronic protection, integrated measurement and 70 kA breaking capacity at 415 V AC for demanding low-voltage power distribution.

SKU: 1SDA101730R1MPN: 1SDA101730R1
Price
List Price £6,275.83 ex VAT
Your Price (ex VAT) Save 25%
£4,706.87 25% OFF
You save £1,568.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,706.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,706.87

Why Choose the ABB XT7H M 800 Ekip Touch Measuring LSI 1SDA101730R1 Circuit Breaker?

The ABB 1SDA101730R1, designated XT7H M 800 Ekip Touch Meas.LSI 800 4p FF, is a high-performance four-pole moulded case circuit breaker (MCCB) designed for protection, switching and measurement in demanding low-voltage AC power distribution systems. As part of the advanced ABB SACE Tmax XT7 range, it combines an 800 A rated current with an Ekip Touch Measuring LSI electronic trip unit and the high short-circuit interruption capability of the XT7H platform.

The ABB Ekip Touch Measuring LSI electronic trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection together with advanced electrical measurement functionality. This combination allows the circuit breaker to protect distribution circuits while providing useful electrical data for monitoring and power-management applications.

With a rated uninterrupted current of 800 A, four-pole construction and front terminal connections, the 1SDA101730R1 is well suited to industrial switchboards, main distribution panels, infrastructure and critical power installations. The XT7H performance level provides a 70 kA rated ultimate short-circuit breaking capacity at 415 V AC, making it suitable for installations with substantial prospective fault currents.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded case circuit breaker.
  • 800 A rated current for high-capacity low-voltage distribution systems.
  • Four-pole configuration suitable for three-phase systems with neutral.
  • 70 kA breaking capacity at 415 V AC for demanding fault levels.
  • Advanced Ekip Touch Measuring LSI electronic trip unit.
  • LSI functionality provides long-time, short-time and instantaneous circuit protection.
  • Integrated measurement functionality supports electrical monitoring and power management.
  • Fixed configuration with front terminal connections for switchboard integration.

Key Features

  • ABB SACE Tmax XT7H M series.
  • 800 A rated uninterrupted current.
  • Four-pole moulded case circuit breaker.
  • Ekip Touch Measuring LSI electronic release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated electrical measurement capabilities.
  • H-class high breaking capacity.
  • 70 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • Suitable for low-voltage AC systems up to 690 V AC.
  • Fixed installation with front terminal connections.
  • Stored-energy operating mechanism.
  • Designed for demanding industrial power distribution and monitoring applications.

Advanced Circuit Protection with Integrated Measurement

Moulded case circuit breakers such as the ABB Tmax XT7 protect low-voltage electrical distribution systems against overloads and short circuits while also providing dependable switching and isolation. The XT7H platform offers high short-circuit interruption capability, helping safeguard cables, switchgear and connected equipment in installations where prospective fault currents can be substantial.

The Ekip Touch Measuring LSI trip unit combines electronic long-time, short-time and instantaneous protection with advanced measurement capabilities. This allows the 1SDA101730R1 to support both circuit protection and electrical system monitoring, making it particularly suitable for modern industrial switchboards, energy-management applications and critical low-voltage distribution networks.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and feeder circuit protection.
  • Power monitoring and energy-management systems.
  • Manufacturing and process industry power distribution.
  • Commercial and infrastructure electrical installations.
  • Data centre and critical power distribution systems.
  • Transformer and generator distribution circuits.
  • High-fault-level low-voltage distribution networks.

Technical Specifications

Series SACE Tmax XT
Frame XT7M
ABB order code 1SDA101730R1
Product type Moulded case circuit breaker (MCCB)
Rated current 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4
Current type AC
Trip unit Ekip Touch Measuring LSI
Release type Electronic
Protection functions L, S and I
Overload protection adjustment 0.4–1 × In
Short-circuit protection adjustment 1–10 × In
Measurement functionality Integrated
Short-circuit performance level H
Rated ultimate short-circuit breaking capacity at 415 V AC 70 kA
Rated operational voltage up to 690 V AC
Installation version Fixed
Terminal connection Front terminals
Operating mechanism Stored-energy mechanism
Mounting application Low-voltage switchboards and distribution assemblies

Frequently Asked Questions

What is the ABB 1SDA101730R1 used for?

The ABB 1SDA101730R1 is an 800 A four-pole moulded case circuit breaker designed for protection, switching and electrical measurement in demanding low-voltage AC power distribution systems.

What protection unit is fitted to the ABB 1SDA101730R1?

The circuit breaker is fitted with an Ekip Touch Measuring LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection together with electrical measurement functionality.

What is the breaking capacity of the ABB XT7H M 800?

The XT7H M 800 provides a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC, making it suitable for demanding low-voltage systems with high prospective fault currents.

What does Measuring LSI mean on this ABB circuit breaker?

LSI denotes long-time, short-time and instantaneous protection functions, while the Measuring version of the Ekip Touch trip unit adds electrical measurement capabilities for monitoring and power-management applications.

How is the ABB XT7H M 800 installed?

The 1SDA101730R1 is a four-pole fixed circuit breaker with front terminal connections, designed for integration into low-voltage switchboards and electrical distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for dependable circuit protection, advanced electrical measurement and reliable high-capacity low-voltage power distribution.