1SDA101713R1 ABB XT7H M 1600 Ekip Dip LS/I 1600 A 4-Pole Circuit Breaker

1SDA101713R1 ABB XT7H M 1600 Ekip Dip LS/I 1600 A 4-Pole Circuit Breaker

ABB 1SDA101713R1 XT7H M 1600 is a 1600 A four-pole fixed moulded-case circuit breaker with front terminals, 70 kA breaking-capacity class and an Ekip Dip LS/I electronic trip unit for high-current low-voltage distribution protection.

SKU: 1SDA101713R1MPN: 1SDA101713R1
Price
List Price £8,193.41 ex VAT
Your Price (ex VAT) Save 25%
£6,145.06 25% OFF
You save £2,048.35 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,145.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,145.06

Why Choose the ABB XT7H M 1600 Ekip Dip LS/I 1SDA101713R1 Circuit Breaker?

The ABB XT7H M 1600 Ekip Dip LS/I, order code 1SDA101713R1, is a high-performance moulded-case circuit breaker (MCCB) from the ABB SACE Tmax XT range, designed for reliable protection and switching in demanding low-voltage electrical distribution systems. Rated at 1600 A, this four-pole breaker combines the high-breaking-capacity XT7H platform with an Ekip Dip LS/I solid-state electronic trip unit.

The Ekip Dip LS/I release provides long-time overload and instantaneous short-circuit protection, with adjustable settings that allow the breaker to be coordinated with conductors and downstream electrical equipment. ABB specifies an overload adjustment range of 0.4–1 × In and an instantaneous protection adjustment range of 1–10 × In, providing flexibility for high-current distribution applications.

This XT7H M configuration features 4 poles, fixed installation, front terminals and a stored-energy operating mechanism. The H interruption rating provides a 70 kA breaking-capacity class at 415 V AC, making the 1SDA101713R1 well suited to main switchboards, industrial distribution systems and high-current feeder protection.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded-case circuit breaker.
  • 1600 A rated current for high-current electrical distribution.
  • 4-pole configuration suitable for three-phase systems incorporating the neutral conductor.
  • Ekip Dip LS/I electronic trip unit for dependable overload and short-circuit protection.
  • Adjustable long-time protection from 0.4–1 × In.
  • Adjustable instantaneous protection from 1–10 × In.
  • 70 kA breaking-capacity class at 415 V AC.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT7H M 1600 circuit breaker configuration.
  • 1600 A rated current.
  • 4-pole design.
  • H interruption rating.
  • Ekip Dip LS/I solid-state electronic release.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 0.4–1 × In long-time protection adjustment range.
  • 1–10 × In instantaneous protection adjustment range.
  • Stored-energy operating mechanism.
  • Fixed installation with front terminals.
  • Designed to IEC requirements.

Reliable Protection for High-Current Distribution Systems

Moulded-case circuit breakers such as the ABB SACE Tmax XT7 protect electrical installations by interrupting current when overload or short-circuit conditions exceed configured protection thresholds. Electronic trip technology provides adjustable protection characteristics, helping engineers coordinate protective devices throughout high-current low-voltage distribution networks.

The Ekip Dip LS/I release combines adjustable long-time overload protection with instantaneous short-circuit protection, while the XT7H M platform provides a high breaking-capacity class. This combination makes the ABB 1SDA101713R1 particularly suitable for demanding feeders and distribution assemblies where robust circuit protection and dependable switching are required.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial electrical distribution systems.
  • High-current feeder protection.
  • Manufacturing and process facilities.
  • Commercial and infrastructure power systems.
  • Four-pole distribution circuits incorporating neutral switching.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101713R1
EAN / UPC 8056221017572
Product type Moulded-case circuit breaker
Frame size XT7M
Rated current 1600 A
Number of poles 4
Trip unit Ekip Dip LS/I
Release type Solid-state electronic release
Protection functions Long-time and instantaneous
Long-time protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1–10 × In
Interruption rating H
Breaking-capacity class at 415 V AC 70 kA
Installation Fixed
Terminal arrangement Front terminals
Operating mechanism Stored-energy operating mechanism
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA101713R1 used for?

The ABB 1SDA101713R1 is a 1600 A moulded-case circuit breaker designed for protection and switching in high-current low-voltage electrical distribution systems.

What trip unit is fitted to the ABB XT7H M 1600?

This circuit breaker is fitted with an ABB Ekip Dip LS/I solid-state electronic trip unit.

What protection functions does the Ekip Dip LS/I provide?

The Ekip Dip LS/I provides long-time overload and instantaneous short-circuit protection, with adjustable protection settings for coordination with the electrical system.

What is the breaking-capacity class of ABB 1SDA101713R1?

The XT7H M configuration has an H interruption rating and a breaking-capacity class of 70 kA at 415 V AC.

How is the ABB XT7H M 1600 installed?

The 1SDA101713R1 is supplied as a fixed four-pole circuit breaker with front terminals and a stored-energy operating mechanism for integration into low-voltage switchboards.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in industrial, commercial and infrastructure power systems where dependable high-current protection, strong breaking performance and flexible electronic trip functionality are required.