1SDA101709R1 ABB XT7S M 1600 Ekip Dip LIG 1600A 4P Circuit Breaker

1SDA101709R1 ABB XT7S M 1600 Ekip Dip LIG 1600A 4P Circuit Breaker

ABB 1SDA101709R1 is a 1600 A four-pole XT7S M fixed moulded case circuit breaker with front terminals and an Ekip Dip LIG electronic trip unit providing overload, instantaneous short-circuit and earth-fault protection.

SKU: 1SDA101709R1MPN: 1SDA101709R1
Price
List Price £8,030.33 ex VAT
Your Price (ex VAT) Save 25%
£6,022.75 25% OFF
You save £2,007.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,022.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,022.75

Why Choose the ABB XT7S M 1600 Ekip Dip LIG Circuit Breaker?

The ABB XT7S M 1600 Ekip Dip LIG, order code 1SDA101709R1, is a high-performance four-pole moulded case circuit breaker from the ABB SACE Tmax XT7 range, designed for reliable protection and switching in demanding low-voltage electrical distribution systems. This configuration combines a 1600 A rated current with the Ekip Dip LIG electronic trip unit for overload, instantaneous short-circuit and earth-fault protection.

The Ekip Dip LIG trip unit provides L, I and G protection functions, covering long-time overload protection, instantaneous short-circuit protection and earth-fault protection. Its electronic protection characteristics enable accurate adjustment to suit high-current distribution circuits, helping protect cables, switchgear and connected equipment against damaging electrical faults.

This XT7S M configuration is supplied as a fixed four-pole circuit breaker with front terminals and a stored-energy operating mechanism. It has a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it suitable for industrial switchboards, main distribution boards and high-current feeder applications.

Key Advantages

  • High-capacity 1600 A moulded case circuit breaker for demanding power-distribution applications.
  • Ekip Dip LIG electronic trip unit for comprehensive electronic protection.
  • Long-time overload protection against sustained overcurrent conditions.
  • Instantaneous short-circuit protection for rapid response to severe faults.
  • Integrated earth-fault protection through the G protection function.
  • 50 kA ultimate breaking capacity at 415 V AC.
  • Four-pole fixed configuration with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT7 series.
  • 1600 A rated current.
  • Ekip Dip LIG solid-state electronic trip unit.
  • LIG protection functions.
  • 640–1600 A overload setting range.
  • 1600–16000 A instantaneous short-circuit setting range.
  • Four-pole construction.
  • Fixed mounting with front terminal connections.
  • 690 V AC rated operational voltage.
  • IP20 protection rating.

Advanced Protection for High-Current Distribution Systems

Moulded case circuit breakers such as the ABB XT7S M protect low-voltage electrical networks against potentially damaging overcurrent and fault conditions while providing dependable switching and isolation. The 1600 A rating and robust short-circuit interruption capability make this breaker suitable for main distribution circuits and other high-current industrial applications.

The Ekip Dip LIG electronic trip unit combines overload, instantaneous short-circuit and earth-fault protection in a single protective device. This combination enables the breaker to respond to several important fault conditions while helping improve electrical safety, equipment protection and continuity of service throughout the distribution system.

Typical Applications

  • Main low-voltage distribution boards.
  • Industrial switchboards and power-distribution systems.
  • High-current incomer and feeder protection.
  • Manufacturing and process-industry installations.
  • Commercial and infrastructure electrical distribution.
  • Circuits requiring overload, instantaneous short-circuit and earth-fault protection.

Technical Specifications

Series SACE Tmax XT7
ABB order code 1SDA101709R1
EAN 8056221017534
Product type Moulded case circuit breaker
Frame XT7 M
Performance class XT7S
Rated current 1600 A
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Trip unit Ekip Dip LIG
Protection functions Long-time, instantaneous and earth-fault
Overload setting range 640–1600 A
Instantaneous short-circuit setting range 1600–16000 A
Poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Ultimate breaking capacity at 415 V AC 50 kA
Ultimate breaking capacity at 690 V AC 30 kA
Rated short-time withstand current 20 kA
Power loss 94 W
Protection rating IP20
Standard IEC 60947-2
ABB product group T-Max XT 250 Range

Frequently Asked Questions

What is the ABB 1SDA101709R1?

The ABB 1SDA101709R1 is an XT7S M fixed four-pole moulded case circuit breaker rated at 1600 A and equipped with an Ekip Dip LIG electronic trip unit.

What protection functions does the Ekip Dip LIG trip unit provide?

The Ekip Dip LIG provides long-time overload, instantaneous short-circuit and earth-fault protection, represented by the L, I and G functions.

What is the breaking capacity of the ABB XT7S M 1600?

The breaker has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC and 30 kA at 690 V AC.

How many poles does the ABB 1SDA101709R1 have?

The breaker has a four-pole configuration and is supplied as a fixed circuit breaker with front terminals.

Where is the ABB XT7S M 1600 Ekip Dip LIG typically used?

It is typically used in industrial switchboards, main distribution boards and high-current feeder circuits requiring electronic overload, instantaneous short-circuit and earth-fault protection.

Trusted ABB Protection for Industrial Power Distribution

ABB SACE Tmax XT circuit breakers combine robust switching performance with advanced electronic protection, providing dependable circuit protection for demanding industrial, commercial and infrastructure power-distribution systems.