1SDA101698R1 ABB XT7S M 800 Ekip G Hi-Touch LSIG 800A 4P Circuit Breaker

1SDA101698R1 ABB XT7S M 800 Ekip G Hi-Touch LSIG 800A 4P Circuit Breaker

ABB 1SDA101698R1 XT7S M 800 is an 800 A four-pole fixed moulded case circuit breaker with an Ekip G Hi-Touch LSIG electronic trip unit and 50 kA breaking capacity at 415 V AC for advanced power distribution and generator protection.

SKU: 1SDA101698R1MPN: 1SDA101698R1
Price
List Price £10,675.77 ex VAT
Your Price (ex VAT) Save 25%
£8,006.83 25% OFF
You save £2,668.94 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,006.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,006.83

Why Choose the ABB XT7S M 800 Ekip G Hi-Touch LSIG 1SDA101698R1 Circuit Breaker?

The ABB 1SDA101698R1 is a high-performance SACE Tmax XT7S moulded case circuit breaker (MCCB) designed for reliable protection and switching in demanding low-voltage electrical distribution systems. This fixed four-pole circuit breaker combines an 800 A rated current with ABB’s advanced Ekip G Hi-Touch LSIG electronic trip unit, providing comprehensive protection for power distribution and generator applications.

As part of the ABB SACE Tmax XT range, the XT7S M 800 is engineered for industrial, commercial and infrastructure installations requiring advanced electronic protection and dependable interruption performance. The Ekip G Hi-Touch LSIG trip unit provides long-time, short-time, instantaneous and ground-fault protection functions, with functionality specifically suited to sophisticated power and generator protection systems.

The 1SDA101698R1 features a four-pole configuration, fixed installation and front terminals. The XT7S S performance level provides a 50 kA breaking capacity at 415 V AC, making this breaker suitable for main distribution boards, generator systems, high-current feeders and other installations where reliable fault interruption and advanced protection are essential.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for demanding low-voltage distribution systems.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for power and generator protection.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • 50 kA breaking capacity at 415 V AC for installations with substantial prospective fault currents.
  • Fixed installation with front terminals for integration into electrical switchboards.
  • Advanced electronic protection supports effective coordination within complex electrical networks.
  • Part of ABB’s established SACE Tmax XT low-voltage circuit breaker platform.

Key Features

  • ABB SACE Tmax XT7S M moulded case circuit breaker.
  • 800 A rated current.
  • Four-pole fixed configuration.
  • Ekip G Hi-Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • S short-circuit performance level.
  • 50 kA breaking capacity at 415 V AC.
  • Front main-circuit terminals.
  • Designed for advanced low-voltage power and generator protection applications.

Advanced Protection for Power and Generator Systems

Moulded case circuit breakers such as the ABB Tmax XT7S protect low-voltage electrical installations by interrupting current when overloads, short circuits or ground faults exceed configured protection thresholds. With its 800 A rated current and high interruption capability, the 1SDA101698R1 is suitable for major feeders, distribution circuits and generator-connected systems where dependable fault clearance is essential.

The Ekip G Hi-Touch LSIG electronic trip unit combines long-time, short-time, instantaneous and ground-fault protection with advanced functionality intended for demanding electrical networks and generator applications. This allows the XT7S to support sophisticated protection strategies and coordination within industrial switchboards, generation systems and complex low-voltage distribution assemblies.

Typical Applications

  • Generator protection and power generation systems.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution systems.
  • High-current feeder protection.
  • Transformer secondary distribution.
  • Manufacturing plants and process facilities.
  • Commercial and infrastructure electrical installations.
  • Electrical systems requiring four-pole switching and LSIG protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101698R1
Product type Moulded case circuit breaker
Frame XT7 M
Rated current 800 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground fault
Short-circuit performance level S
Breaking capacity at 415 V AC 50 kA
Current type AC
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Stored-energy mechanism
Application Power distribution and generator protection

Frequently Asked Questions

What is the ABB 1SDA101698R1 used for?

The ABB 1SDA101698R1 is an 800 A four-pole moulded case circuit breaker designed for protection and switching in low-voltage power distribution and generator applications.

What trip unit is fitted to the ABB 1SDA101698R1?

This circuit breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions.

What is the breaking capacity of the XT7S M 800?

The XT7S S-performance configuration provides a breaking capacity of 50 kA at 415 V AC, making it suitable for demanding low-voltage systems with substantial prospective fault currents.

How many poles does the ABB 1SDA101698R1 have?

The 1SDA101698R1 is a four-pole circuit breaker, making it suitable for three-phase electrical systems where switching of the neutral conductor is also required.

What is the Ekip G Hi-Touch LSIG trip unit designed for?

The Ekip G Hi-Touch LSIG electronic trip unit provides advanced protection functions for demanding power distribution and generator applications, including long-time, short-time, instantaneous and ground-fault protection.

Trusted for Advanced Power Protection

ABB SACE Tmax XT circuit breakers combine high interruption performance, advanced electronic protection and flexible system integration for dependable low-voltage power distribution and generator protection across industrial, commercial and infrastructure applications.