1SDA101693R1 ABB XT7S M 1600 Ekip G Dip LS/I 1600A 4P Circuit Breaker

1SDA101693R1 ABB XT7S M 1600 Ekip G Dip LS/I 1600A 4P Circuit Breaker

ABB 1SDA101693R1 is a 1600 A four-pole XT7S M fixed moulded case circuit breaker with front terminals and an Ekip G Dip LS/I electronic trip unit for generator and low-voltage circuit protection.

SKU: 1SDA101693R1MPN: 1SDA101693R1
Price
List Price £7,392.92 ex VAT
Your Price (ex VAT) Save 25%
£5,544.69 25% OFF
You save £1,848.23 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,544.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,544.69

Why Choose the ABB XT7S M 1600 Ekip G Dip LS/I Circuit Breaker?

The ABB XT7S M 1600 Ekip G Dip LS/I, order code 1SDA101693R1, is a high-performance four-pole moulded case circuit breaker from the ABB SACE Tmax XT7 range, engineered for generator protection and demanding low-voltage power-distribution applications. It combines a 1600 A rated current with the specialised Ekip G Dip LS/I electronic trip unit for dependable overload and short-circuit protection.

The Ekip G Dip LS/I trip unit is specifically designed for generator applications and provides long-time overload protection together with short-time and instantaneous short-circuit protection functionality. Its adjustable electronic protection characteristics allow effective coordination with generators, cables and downstream equipment, helping maintain continuity of service while protecting electrical assets against damaging fault currents.

This XT7S M configuration is supplied as a fixed four-pole circuit breaker with front terminals. The XT7S generator-protection version has a 50 kA breaking-capacity class, making the 1600 A breaker well suited to generator switchboards, standby power installations and high-current industrial distribution systems.

Key Advantages

  • High-capacity 1600 A moulded case circuit breaker for generator and power-distribution applications.
  • Specialised Ekip G Dip LS/I electronic trip unit for generator protection.
  • Electronic overload and short-circuit protection with adjustable characteristics.
  • Four-pole configuration for comprehensive low-voltage circuit switching and protection.
  • XT7S 50 kA breaking-capacity class for demanding fault levels.
  • Fixed mounting with front terminals for straightforward switchboard integration.
  • Part of ABB's advanced SACE Tmax XT circuit-breaker platform.

Key Features

  • ABB SACE Tmax XT7 series.
  • 1600 A rated current.
  • Ekip G Dip LS/I electronic trip unit.
  • Generator-oriented protection functionality.
  • LS/I protection functions.
  • Four-pole construction.
  • Fixed mounting configuration.
  • Front terminal connections.
  • XT7S 50 kA performance class.
  • Designed for high-current generator and industrial low-voltage distribution systems.

Reliable Generator and Power Distribution Protection

Moulded case circuit breakers such as the ABB XT7S M protect low-voltage electrical networks against overload and short-circuit conditions while providing dependable switching and isolation. The 1600 A current rating and XT7S 50 kA performance class make this configuration suitable for generator switchboards, industrial distribution boards and other high-current installations.

The Ekip G Dip LS/I electronic trip unit is specifically suited to generator protection requirements. Its adjustable protection characteristics help coordinate the circuit breaker with generator capabilities and downstream protective devices, supporting continuity of service while reducing the risk of equipment damage caused by sustained overloads and short-circuit faults.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Main low-voltage distribution boards.
  • Industrial switchboards and power-distribution systems.
  • High-current incomer and feeder circuits.
  • Manufacturing, infrastructure and process-industry installations.

Technical Specifications

Series SACE Tmax XT7
ABB order code 1SDA101693R1
Product type Moulded case circuit breaker
Frame XT7 M
Performance class XT7S
Rated current 1600 A
Trip unit Ekip G Dip LS/I
Protection functions LS/I
Application Generator protection
Poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Breaking-capacity class 50 kA
Rated voltage range 220–690 V
Release type Electronic
ABB product group T-Max XT 250 Range

Frequently Asked Questions

What is the ABB 1SDA101693R1?

The ABB 1SDA101693R1 is an XT7S M fixed four-pole moulded case circuit breaker rated at 1600 A and equipped with an Ekip G Dip LS/I electronic trip unit.

What is the Ekip G Dip LS/I trip unit designed for?

The Ekip G Dip LS/I trip unit is designed for generator protection, providing adjustable electronic overload and short-circuit protection for generator-connected electrical systems.

What is the breaking-capacity class of this circuit breaker?

The ABB XT7S M 1600 Ekip G Dip LS/I has an XT7S 50 kA breaking-capacity class.

How many poles does the ABB 1SDA101693R1 have?

The breaker has a four-pole configuration and is supplied as a fixed circuit breaker with front terminals.

Where is the ABB XT7S M 1600 Ekip G Dip LS/I typically used?

It is typically used in generator switchboards, standby power systems and industrial low-voltage distribution installations requiring high-current generator-oriented electronic protection.

Trusted ABB Protection for Generator and Industrial Power Systems

ABB SACE Tmax XT circuit breakers combine robust switching performance with specialised electronic protection, providing dependable protection for generators and demanding industrial low-voltage power-distribution systems.