1SDA101692R1 ABB XT7S M 1250 Ekip G Dip LS/I 1250A 4P Circuit Breaker

1SDA101692R1 ABB XT7S M 1250 Ekip G Dip LS/I 1250A 4P Circuit Breaker

ABB 1SDA101692R1 is a 1250 A four-pole XT7S M fixed moulded case circuit breaker with front terminals, stored-energy operation and an Ekip G Dip LS/I electronic trip unit for generator and low-voltage circuit protection.

SKU: 1SDA101692R1MPN: 1SDA101692R1
Price
List Price £5,529.70 ex VAT
Your Price (ex VAT) Save 25%
£4,147.28 25% OFF
You save £1,382.43 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,147.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,147.28

Why Choose the ABB XT7S M 1250 Ekip G Dip LS/I Circuit Breaker?

The ABB XT7S M 1250 Ekip G Dip LS/I, order code 1SDA101692R1, is a high-performance four-pole moulded case circuit breaker from the ABB SACE Tmax XT7 range, designed for generator protection and demanding low-voltage electrical distribution applications. It combines a 1250 A rated current with the specialised Ekip G Dip LS/I solid-state electronic trip unit.

The Ekip G Dip LS/I trip unit is designed for generator applications and provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection. Its electronic protection characteristics support effective coordination of generators, cables and downstream equipment, helping maintain dependable system operation while protecting against damaging overcurrents.

This XT7S M configuration is supplied as a fixed four-pole circuit breaker with front terminals and a stored-energy operating mechanism. The XT7S performance class provides an ultimate short-circuit breaking capacity of 50 kA in the applicable system configuration, making the breaker suitable for generator switchboards and other high-current industrial power-distribution systems.

Key Advantages

  • High-capacity 1250 A moulded case circuit breaker for generator and power-distribution applications.
  • Specialised Ekip G Dip LS/I electronic trip unit for generator protection.
  • Provides long-time and selectable short-time or instantaneous protection.
  • Four-pole configuration for comprehensive low-voltage circuit switching and protection.
  • XT7S 50 kA performance class for demanding fault levels.
  • Fixed mounting with front terminals for straightforward switchboard integration.
  • Stored-energy operating mechanism for dependable switching operation.

Key Features

  • ABB SACE Tmax XT7 series.
  • 1250 A rated current.
  • Ekip G Dip LS/I solid-state electronic trip unit.
  • Generator-oriented electronic protection functionality.
  • LS/I protection functions.
  • Four-pole construction.
  • Fixed mounting configuration.
  • Front terminal connections.
  • Stored-energy operating mechanism.
  • Designed for demanding industrial and generator-related low-voltage systems.

Reliable Generator and Power Distribution Protection

Moulded case circuit breakers such as the ABB XT7S M protect low-voltage electrical networks against overload and short-circuit conditions while providing dependable switching and isolation. The 1250 A current rating and XT7S interruption performance make this configuration suitable for generator switchboards, industrial distribution boards and other high-current installations.

The Ekip G Dip LS/I electronic trip unit is specifically suited to generator protection requirements. Its configurable protection characteristics help coordinate the circuit breaker with generator capabilities and downstream protective devices, supporting continuity of service while reducing the risk of damage caused by sustained overloads or short-circuit faults.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Main low-voltage distribution boards.
  • Industrial switchboards and power-distribution systems.
  • High-current incomer and feeder circuits.
  • Manufacturing, infrastructure and process-industry installations.

Technical Specifications

Series SACE Tmax XT7
ABB order code 1SDA101692R1
EAN 8056221017367
Product type Moulded case circuit breaker
Frame size XT7M
Performance class XT7S
Rated current 1250 A
Trip unit Ekip G Dip LS/I
Protection functions Long-time and short-time / instantaneous
Application Generator protection
Poles 4
Mounting type Fixed
Terminal arrangement Front terminals
Operating mechanism Stored energy
XT7S breaking-capacity class 50 kA
Release type Solid-state electronic release for AC applications
Standard IEC
ABB product group T-Max XT 250 Range

Frequently Asked Questions

What is the ABB 1SDA101692R1?

The ABB 1SDA101692R1 is an XT7S M fixed four-pole moulded case circuit breaker rated at 1250 A and equipped with an Ekip G Dip LS/I electronic trip unit.

What is the Ekip G Dip LS/I trip unit designed for?

The Ekip G Dip LS/I is designed for generator protection, providing electronic overload and short-circuit protection suited to generator-connected electrical systems.

What protection functions does this breaker provide?

The Ekip G Dip LS/I provides long-time protection together with selectable short-time or instantaneous short-circuit protection.

How many poles does the ABB 1SDA101692R1 have?

The breaker has a four-pole configuration and is supplied as a fixed circuit breaker with front terminals.

Where is the ABB XT7S M 1250 Ekip G Dip LS/I typically used?

It is typically used in generator switchboards, standby power systems and industrial low-voltage distribution installations requiring generator-oriented electronic protection.

Trusted ABB Protection for Generator and Industrial Power Systems