1SDA101681R1 ABB XT7S M 1600 Ekip Touch Measuring LSIG 1600 A 4-Pole Circuit Breaker

1SDA101681R1 ABB XT7S M 1600 Ekip Touch Measuring LSIG 1600 A 4-Pole Circuit Breaker

ABB 1SDA101681R1 XT7S M 1600 is a 1600 A four-pole fixed moulded-case circuit breaker with Ekip Touch Measuring LSIG electronic protection and measurement for high-current low-voltage distribution systems.

SKU: 1SDA101681R1MPN: 1SDA101681R1
Price
List Price £10,733.64 ex VAT
Your Price (ex VAT) Save 25%
£8,050.23 25% OFF
You save £2,683.41 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,050.23
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,050.23

Why Choose the ABB XT7S M 1600 Ekip Touch Measuring LSIG 1SDA101681R1 Circuit Breaker?

The ABB XT7S M 1600 Ekip Touch Measuring LSIG, order code 1SDA101681R1, is a high-performance moulded-case circuit breaker (MCCB) from the ABB SACE Tmax XT7 range, designed for protection, switching and electrical measurement in demanding low-voltage power distribution systems. Rated at 1600 A, this four-pole breaker combines high-current capability with an advanced Ekip Touch Measuring LSIG electronic trip unit.

The Ekip Touch Measuring LSIG release provides long-time, short-time, instantaneous and earth-fault protection functions together with integrated electrical measurement capabilities. This combination supports accurate circuit protection, system monitoring and protection coordination across industrial and commercial low-voltage distribution networks.

This XT7S M configuration features 4 poles, fixed installation and front terminals, with a rated operational voltage of 690 V AC. Its S performance level provides a rated ultimate and service short-circuit breaking capacity of 50 kA at 415 V AC, making it well suited to main switchboards, high-current feeders and critical power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded-case circuit breaker.
  • 1600 A rated current for high-current power distribution.
  • 4-pole configuration for three-phase systems incorporating the neutral conductor.
  • Advanced Ekip Touch Measuring LSIG electronic trip unit.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • Integrated measurement functionality supports electrical system monitoring.
  • 50 kA breaking capacity at 415 V AC for demanding distribution systems.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT7 series.
  • XT7S M 1600 circuit breaker configuration.
  • 1600 A rated current.
  • 4-pole design.
  • 690 V AC rated operational voltage.
  • Ekip Touch Measuring LSIG electronic protection release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Earth-fault protection.
  • Integrated electrical measurement functionality.
  • 50 kA Icu/Ics at 415 V AC.
  • 8 kV rated impulse withstand voltage.
  • Fixed installation with front terminals.

Reliable Protection and Measurement for High-Current Distribution

Moulded-case circuit breakers such as the ABB SACE Tmax XT7 protect electrical installations by interrupting current when overload, short-circuit or earth-fault conditions exceed the configured protection thresholds. Electronic trip technology provides accurate protection characteristics that support effective coordination and dependable operation across complex low-voltage distribution networks.

The Ekip Touch Measuring LSIG release combines comprehensive LSIG protection with electrical measurement functionality, allowing the XT7S M to support both system protection and operating-data visibility. This makes the breaker particularly suitable for modern industrial and commercial switchboards where high-current protection, monitoring and efficient power management are important.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • High-current feeder protection.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical systems.
  • Distribution systems requiring earth-fault protection and electrical measurement.

Technical Specifications

Series SACE Tmax XT7
Order code 1SDA101681R1
Product type Moulded-case circuit breaker
Frame / sub-type XT7M
Rated current 1600 A
Rated uninterrupted current 1600 A
Number of poles 4
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate breaking capacity at 415 V AC 50 kA
Service breaking capacity at 415 V AC 50 kA
Short-time withstand current 20 kA
Trip unit Ekip Touch Measuring LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Short-circuit performance level S
Installation Fixed
Terminal connection Front
Standard IEC 60947-2
Power loss at rated operating conditions per pole 94 W

Frequently Asked Questions

What is the ABB 1SDA101681R1 used for?

The ABB 1SDA101681R1 is a 1600 A moulded-case circuit breaker designed for protection, switching and electrical measurement in high-current low-voltage distribution systems.

What trip unit is fitted to the ABB XT7S M 1600?

This circuit breaker is fitted with an ABB Ekip Touch Measuring LSIG electronic trip unit, combining advanced circuit protection with electrical measurement functionality.

What protection functions does the Ekip Touch Measuring LSIG provide?

The trip unit provides long-time, short-time, instantaneous and earth-fault protection, commonly referred to as LSIG protection.

What are the main electrical ratings of ABB 1SDA101681R1?

The breaker is rated at 1600 A with 4 poles, a rated operational voltage of 690 V AC and a breaking capacity of 50 kA at 415 V AC.

How is the ABB XT7S M 1600 installed?

The 1SDA101681R1 is supplied as a fixed circuit breaker with front terminals, making it suitable for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in industrial, commercial and infrastructure power systems where dependable protection, high breaking performance, advanced measurement and flexible electronic trip functionality are required.