1SDA101665R1 ABB XT7S M 1600 Ekip Dip LSIG 1600A 4P Circuit Breaker

1SDA101665R1 ABB XT7S M 1600 Ekip Dip LSIG 1600A 4P Circuit Breaker

ABB 1SDA101665R1 XT7S M 1600 is a 1600 A four-pole fixed moulded case circuit breaker with an Ekip Dip LSIG electronic trip unit and 50 kA breaking capacity at 415 V AC for high-current low-voltage power distribution.

SKU: 1SDA101665R1MPN: 1SDA101665R1
Price
List Price £7,804.41 ex VAT
Your Price (ex VAT) Save 25%
£5,853.31 25% OFF
You save £1,951.10 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,853.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,853.31

Why Choose the ABB XT7S M 1600 Ekip Dip LSIG 1SDA101665R1 Circuit Breaker?

The ABB 1SDA101665R1 is a high-performance Tmax XT7S moulded case circuit breaker (MCCB) designed for reliable protection and switching of high-current low-voltage electrical distribution systems. This fixed four-pole circuit breaker combines a 1600 A rated current with ABB’s electronic Ekip Dip LSIG trip unit, providing comprehensive protection against overload, short circuit and earth-fault conditions.

As part of the ABB SACE Tmax XT range, the XT7S M 1600 is engineered for demanding industrial and commercial power distribution applications. Its electronic LSIG protection provides long-time, short-time, instantaneous and ground-fault protection functions, while the stored-energy operating mechanism supports dependable switching within switchboards and distribution assemblies.

The 1SDA101665R1 features a four-pole fixed configuration with front terminals, a rated operational voltage of up to 690 V AC and an S-level short-circuit performance of 50 kA at 415 V AC. Its robust construction and high current capacity make it particularly suitable for main distribution, transformer protection, generator systems and large industrial installations.

Key Advantages

  • High-capacity 1600 A moulded case circuit breaker for demanding power distribution systems.
  • Ekip Dip LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection.
  • Four-pole configuration allows switching and protection of three phases and neutral.
  • 50 kA breaking capacity at 415 V AC for robust fault protection.
  • Rated for operation at voltages up to 690 V AC.
  • Fixed installation with front terminals for integration into switchboards and distribution panels.
  • Stored-energy operating mechanism provides reliable circuit-breaker operation.
  • Designed and tested in accordance with IEC 60947-2.

Key Features

  • ABB SACE Tmax XT7S moulded case circuit breaker.
  • 1600 A rated current.
  • Four-pole fixed configuration.
  • Ekip Dip LSIG solid-state electronic release.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • S short-circuit performance level.
  • 50 kA Icu and Ics at 380–440 V AC.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV impulse withstand voltage.
  • Front main-circuit terminals.
  • Stored-energy operating mechanism.

Reliable Circuit Protection for High-Current Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT7S protect electrical installations by automatically interrupting current when overloads, short circuits or other abnormal conditions occur. The 1600 A current rating and high breaking capacity of this model make it suitable for major feeders and incoming supplies where dependable fault interruption is essential.

The Ekip Dip LSIG electronic trip unit provides configurable electronic protection functions for long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault conditions. This combination allows the circuit breaker to provide coordinated protection within complex low-voltage distribution systems while supporting selective operation with upstream and downstream protective devices.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution systems.
  • Transformer secondary protection.
  • Generator and standby power distribution.
  • Large commercial and infrastructure installations.
  • Manufacturing plants and process facilities.
  • High-current feeder protection.
  • Electrical installations requiring four-pole switching and LSIG protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101665R1
Product type Moulded case circuit breaker
Frame / sub-type XT7M
Rated current 1600 A
Number of poles 4
Trip unit Ekip Dip LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground fault
Rated operational voltage up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate breaking capacity (Icu) at 380–440 V AC 50 kA
Rated service breaking capacity (Ics) at 380–440 V AC 50 kA
Icu / Ics at 500–525 V AC 45 kA
Icu / Ics at 690 V AC 30 kA
Rated short-time withstand current (Icw) 20 kA
Short-circuit performance level S
Current type AC
Mounting type Fixed
Terminal connection Front
Operating mechanism Stored energy
Standard IEC 60947-2
Mechanical durability 20,000 cycles
Electrical durability 3,000 cycles
Power loss at rated operating conditions 94 W per pole
Dimensions (H × W × D) 268 × 280 × 178 mm
Weight 14 kg

Frequently Asked Questions

What is the ABB 1SDA101665R1 used for?

The ABB 1SDA101665R1 is a 1600 A four-pole moulded case circuit breaker designed to protect high-current low-voltage electrical distribution systems against overloads, short circuits and ground faults.

What trip unit is fitted to the ABB 1SDA101665R1?

This circuit breaker is fitted with an Ekip Dip LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions.

What is the breaking capacity of the XT7S M 1600?

The S-performance version has a rated ultimate and service short-circuit breaking capacity of 50 kA at 415 V AC.

How many poles does the 1SDA101665R1 have?

The 1SDA101665R1 is a four-pole circuit breaker, allowing protection and switching of all three phases together with the neutral conductor.

How is the ABB XT7S M 1600 installed?

This model is a fixed-mounted circuit breaker with front terminals and a stored-energy operating mechanism, designed for installation within electrical switchboards and power distribution assemblies.

Trusted for Industrial Power Distribution

ABB SACE Tmax XT circuit breakers are engineered for dependable low-voltage power distribution, combining high breaking performance, electronic protection and flexible installation options for industrial, commercial and infrastructure applications.