1SDA101511R1 ABB XT7L M 1000 Ekip Touch LSIG 1000 A 3-Pole Circuit Breaker

1SDA101511R1 ABB XT7L M 1000 Ekip Touch LSIG 1000 A 3-Pole Circuit Breaker

ABB 1SDA101511R1 XT7L M 1000 is a 1000 A three-pole fixed moulded case circuit breaker with front terminals, 120 kA ultimate breaking capacity at 415 V AC and an Ekip Touch LSIG electronic trip unit for advanced low-voltage distribution protection.

SKU: 1SDA101511R1MPN: 1SDA101511R1
Price
List Price £8,674.74 ex VAT
Your Price (ex VAT) Save 25%
£6,506.06 25% OFF
You save £2,168.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,506.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,506.06

Why Choose the ABB XT7L M 1000 Ekip Touch LSIG Circuit Breaker?

The ABB XT7L M 1000 Ekip Touch LSIG, order code 1SDA101511R1, is a high-performance three-pole moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution applications. Part of the ABB SACE Tmax XT7 family, it combines a 1000 A rated uninterrupted current with an advanced Ekip Touch LSIG solid-state electronic trip unit and the high short-circuit performance of the XT7L platform.

The Ekip Touch LSIG trip unit provides long-time, short-time, instantaneous and ground-fault protection functions, delivering comprehensive electronic protection against overload, short-circuit and earth-fault conditions. Its advanced protection architecture supports effective coordination in industrial, infrastructure and commercial electrical systems where dependable protection and continuity of service are essential.

With a 1000 A rating, three-pole configuration, fixed construction, front terminals and a stored-energy operating mechanism, the 1SDA101511R1 is engineered for high-current switchboard applications. The XT7L provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, with high breaking performance maintained across a wide range of low-voltage system voltages.

Key Advantages

  • High-performance 1000 A moulded case circuit breaker for demanding low-voltage distribution systems.
  • Ekip Touch LSIG electronic trip unit provides comprehensive adjustable circuit protection.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Ultimate short-circuit breaking capacity of 120 kA at 415 V AC.
  • High breaking performance across distribution voltages up to 690 V AC.
  • Fixed three-pole construction with front terminals and stored-energy operating mechanism.

Key Features

  • ABB SACE Tmax XT7L M moulded case circuit breaker.
  • 1000 A rated uninterrupted current.
  • Three-pole configuration.
  • Ekip Touch LSIG solid-state electronic trip unit.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • 120 kA Icu at 415 V AC.
  • 100 kA Icu at 440 V AC.
  • 85 kA Icu at 500 V AC.
  • 65 kA Icu at 525 V AC.
  • 50 kA Icu at 690 V AC.
  • Fixed installation with front terminals.
  • Stored-energy and lever operating mechanisms.
  • Designed to IEC 60947 requirements.

Advanced LSIG Protection for High-Fault Distribution Systems

High-current electrical distribution systems require protection against multiple fault conditions while maintaining appropriate selectivity between upstream and downstream devices. The ABB Ekip Touch LSIG trip unit combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection within an advanced electronic platform, enabling comprehensive protection of feeders and distribution circuits.

The 1SDA101511R1 is particularly suited to installations with high prospective short-circuit currents, providing an ultimate breaking capacity of 120 kA at 415 V AC and 50 kA at 690 V AC. Combined with its 1000 A current rating, fixed front-terminal construction and stored-energy operating mechanism, this makes the XT7L M 1000 a robust choice for demanding industrial and commercial switchboards.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • High-current feeder protection.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure and utility installations.
  • Transformer secondary distribution systems.
  • Installations requiring LSIG protection against overload, short-circuit and ground-fault conditions.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101511R1
EAN 8056221015554
Product type Moulded case circuit breaker
Frame / sub-type XT7M
Short-circuit performance level L
Rated uninterrupted current (Iu) 1000 A
Number of poles 3
Trip unit Ekip Touch LSIG
Trip-unit technology Solid-state electronic
Protection functions Long-time, short-time, instantaneous and ground fault
Ultimate breaking capacity (Icu) at 415 V AC 120 kA
Ultimate breaking capacity (Icu) at 440 V AC 100 kA
Ultimate breaking capacity (Icu) at 500 V AC 85 kA
Ultimate breaking capacity (Icu) at 525 V AC 65 kA
Ultimate breaking capacity (Icu) at 690 V AC 50 kA
Installation Fixed
Terminal configuration Front terminals
Operating mechanism Stored-energy and lever operating mechanism
Standard IEC 60947
Product dimensions 210 mm wide × 268 mm high × 178 mm deep
Product net weight approx. 9.7 kg

Frequently Asked Questions

What is the ABB 1SDA101511R1 used for?

The ABB 1SDA101511R1 is a 1000 A three-pole moulded case circuit breaker designed for protection and switching of demanding low-voltage power distribution circuits, including systems with high prospective short-circuit currents.

What trip unit is fitted to the ABB XT7L M 1000?

The breaker is fitted with an Ekip Touch LSIG solid-state electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection functions.

What is the rated current of the ABB 1SDA101511R1?

The ABB 1SDA101511R1 has a rated uninterrupted current of 1000 A and is configured as a three-pole breaker for high-current low-voltage distribution applications.

What is the breaking capacity of the ABB XT7L M 1000?

The ABB XT7L M 1000 provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, 100 kA at 440 V AC, 85 kA at 500 V AC, 65 kA at 525 V AC and 50 kA at 690 V AC.

How is the ABB 1SDA101511R1 installed?

The 1SDA101511R1 is a fixed three-pole circuit breaker with front terminals and incorporates stored-energy and lever operating mechanisms for integration into low-voltage distribution switchboards.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers combine advanced electronic protection, high fault-breaking performance and robust switchboard integration for demanding industrial, infrastructure and commercial low-voltage power distribution systems.