ABB 1SDA101454R1 XT7H M 800 Ekip Touch Measuring LSIG is an 800 A three-pole fixed moulded-case circuit breaker with electronic LSIG protection, integrated electrical measurement, front terminals, a stored-energy operating mechanism and XT7H 70 kA breaking-capacity performance.

SKU: 1SDA101454R1MPN: 1SDA101454R1
Price
List Price £6,040.51 ex VAT
Your Price (ex VAT) Save 25%
£4,530.38 25% OFF
You save £1,510.13 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,530.38
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,530.38

Why Choose the ABB XT7H M 800 Ekip Touch Measuring LSIG 800 3p FF Circuit Breaker?

The ABB 1SDA101454R1, designated XT7H M 800 Ekip Touch Meas.LSIG 800 3pFF, is a high-performance three-pole moulded-case circuit breaker (MCCB) designed for advanced protection, measurement and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT7 M range, it combines an 800 A rated current with an Ekip Touch Measuring LSIG electronic trip unit and a stored-energy operating mechanism.

The Ekip Touch Measuring LSIG trip unit combines long-time overload, selective short-time, instantaneous short-circuit and ground-fault protection with advanced electrical measurement functionality. This comprehensive protection architecture supports effective protection coordination while providing valuable electrical data for monitoring, energy management and optimisation of modern distribution systems.

The XT7H M configuration provides 70 kA breaking-capacity performance. Its fixed three-pole construction, front terminals and stored-energy operating mechanism make the 1SDA101454R1 particularly suitable for industrial switchboards, transformer distribution, critical feeders and intelligent power systems requiring advanced protection, measurement and switching capability.

Key Advantages

  • High-performance ABB SACE Tmax XT7H M moulded-case circuit breaker.
  • 800 A rated current for demanding low-voltage distribution applications.
  • 70 kA XT7H breaking-capacity performance for high-fault-level installations.
  • Ekip Touch Measuring LSIG combines advanced electronic protection with electrical measurement.
  • Long-time, selective short-time, instantaneous and ground-fault protection.
  • Integrated measurement functionality supports power monitoring and energy-management applications.
  • Three-pole fixed configuration with front terminals for switchboard integration.
  • Stored-energy operating mechanism supports advanced switching and automation applications when equipped with suitable accessories.

Key Features

  • ABB SACE Tmax XT7H M series.
  • 800 A rated current (In).
  • Three-pole construction.
  • Ekip Touch Measuring LSIG electronic trip unit.
  • Long-time overload protection.
  • Selective short-time and instantaneous short-circuit protection.
  • Ground-fault protection.
  • Integrated electrical measurement functionality.
  • 70 kA XT7H performance class.
  • Fixed installation with front terminals and a stored-energy operating mechanism.

Advanced LSIG Protection, Measurement and Switching

The ABB XT7H M with Ekip Touch Measuring LSIG combines comprehensive circuit protection with advanced electrical measurement in a single high-current device. Its long-time, selective short-time, instantaneous and ground-fault functions provide protection against the principal overload and fault conditions encountered in low-voltage distribution networks, while the measuring functionality provides greater visibility into electrical system performance.

The XT7 M platform incorporates a stored-energy operating mechanism suited to installations requiring enhanced switching functionality. When combined with appropriate ABB accessories, the breaker can support remote and automated operation, making it suitable for intelligent switchboards, transformer distribution, industrial power-management systems and critical installations where protection, measurement and switching need to be closely integrated.

Typical Applications

  • Industrial low-voltage switchboards and intelligent distribution panels.
  • Main incoming and outgoing high-current circuits.
  • Transformer secondary distribution systems.
  • High-current three-phase feeder protection.
  • Distribution systems requiring electronic ground-fault protection.
  • Power monitoring and energy-management applications.
  • Remote and automated switching systems with suitable accessories.

Technical Specifications

Series SACE Tmax XT
ABB product group T-Max XT 250 Range
Order code / MPN 1SDA101454R1
EAN / GTIN 8056221012683
Product type Moulded-case circuit breaker (MCCB)
Frame size XT7M
Performance level XT7H
Rated current (In) 800 A
Number of poles 3
Trip unit Ekip Touch Measuring LSIG
Trip unit technology Electronic
Protection functions Long-time, selective short-time, instantaneous and ground-fault (LSIG)
Breaking-capacity class 70 kA
Interruption rating H
Installation Fixed
Terminal arrangement Front terminals (F)
Operating mechanism Stored-energy operating mechanism
Product net weight 11.2 kg
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA101454R1 used for?

The ABB 1SDA101454R1 is an 800 A three-pole moulded-case circuit breaker designed for demanding low-voltage power distribution applications requiring electronic LSIG protection, electrical measurement, high breaking-capacity performance and stored-energy switching functionality.

What current rating does the ABB XT7H M 800 support?

The ABB XT7H M 800 has a rated current of 800 A, making it suitable for high-current three-phase feeders, industrial switchboards and transformer distribution systems.

What is the breaking-capacity class of the ABB XT7H M 800?

The ABB 1SDA101454R1 belongs to the XT7H 70 kA performance class, providing higher short-circuit interruption performance for demanding low-voltage installations.

What protection functions does the Ekip Touch Measuring LSIG trip unit provide?

The Ekip Touch Measuring LSIG electronic trip unit provides long-time overload, selective short-time, instantaneous short-circuit and ground-fault protection, while also incorporating electrical measurement functionality for monitoring and power-management applications.

How is the ABB 1SDA101454R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and advanced power distribution assemblies.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Tmax XT moulded-case circuit breakers combine dependable circuit protection with advanced electronic trip technology, measurement and robust switching functionality for demanding low-voltage power distribution applications.