1SDA101375R1 ABB XT7S M 1000 Ekip Dip LSIG 1000 A 3-Pole Circuit Breaker

1SDA101375R1 ABB XT7S M 1000 Ekip Dip LSIG 1000 A 3-Pole Circuit Breaker

ABB 1SDA101375R1 XT7S M 1000 is a 1000 A three-pole fixed moulded-case circuit breaker with front terminals, a stored-energy operating mechanism and an Ekip Dip LSIG electronic trip unit for low-voltage power distribution protection.

SKU: 1SDA101375R1MPN: 1SDA101375R1
Price
List Price £4,533.82 ex VAT
Your Price (ex VAT) Save 25%
£3,400.37 25% OFF
You save £1,133.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,400.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,400.37

Why Choose the ABB XT7S M 1000 Ekip Dip LSIG 1SDA101375R1 Circuit Breaker?

The ABB 1SDA101375R1 is a high-performance SACE Tmax XT7S M moulded-case circuit breaker (MCCB) designed for reliable protection and switching of low-voltage electrical distribution systems. Rated at 1000 A, this three-pole circuit breaker combines the robust XT7 platform with ABB’s electronic Ekip Dip LSIG trip unit for comprehensive protection against overloads, short circuits and ground faults.

As part of the ABB SACE Tmax XT range, the XT7S M is engineered for demanding industrial and commercial power distribution applications. Its Ekip Dip LSIG solid-state release provides long-time, short-time, instantaneous and ground-fault protection, helping engineers achieve effective circuit protection and coordination across complex low-voltage installations.

The XT7S M 1000 has a rated current of 1000 A, a rated operational voltage of up to 690 V AC and a three-pole fixed configuration with front terminals. This version also incorporates a stored-energy operating mechanism, making it well suited to high-current switchboards, industrial distribution systems and other applications requiring dependable circuit switching and protection.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded-case circuit breaker for low-voltage power distribution.
  • 1000 A rated current suitable for demanding industrial and commercial electrical systems.
  • Ekip Dip LSIG electronic trip unit providing comprehensive circuit protection.
  • LSIG functionality provides long-time, short-time, instantaneous and ground-fault protection.
  • Three-pole fixed configuration for three-phase power distribution systems.
  • Front terminals support practical installation and connection within switchboards.
  • Stored-energy operating mechanism for dependable circuit breaker operation.
  • Rated operational voltage up to 690 V AC for industrial low-voltage networks.

Key Features

  • ABB SACE Tmax XT7S M series.
  • 1000 A rated current (In).
  • Three-pole construction.
  • Ekip Dip LSIG solid-state electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • S interruption rating.
  • Fixed mounting with front terminals.
  • Stored-energy operating mechanism.
  • Designed in accordance with IEC requirements for low-voltage circuit breakers.

Reliable Circuit Protection for Power Distribution

Moulded-case circuit breakers such as the ABB Tmax XT7 protect electrical distribution systems by automatically interrupting current when abnormal operating conditions occur. Electronic trip technology enables accurate protection characteristics and supports coordination between protective devices throughout industrial and commercial electrical installations.

The Ekip Dip LSIG trip unit combines overload, delayed short-circuit, instantaneous short-circuit and ground-fault protection in one electronic protection system. Together with the XT7S M stored-energy operating mechanism and robust fixed construction, this makes the 1SDA101375R1 particularly suitable for main distribution boards, industrial switchboards and high-current power distribution applications.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Industrial switchboards and power distribution panels.
  • Manufacturing and process plant electrical systems.
  • Commercial building power distribution.
  • Infrastructure and utility distribution installations.
  • Protection of high-current feeders and distribution circuits.
  • Three-phase industrial power networks.

Technical Specifications

Series SACE Tmax XT
Frame size XT7M
Order code / SKU 1SDA101375R1
ABB product group T-Max XT 250 Range
Product type Moulded-case circuit breaker (MCCB)
Rated current (In) 1000 A
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Number of poles 3
Current type AC
Trip unit Ekip Dip LSIG
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Interruption rating S
Mounting configuration Fixed
Terminal type Front terminals
Operating mechanism Stored energy
Mechanical durability 20,000 cycles
Electrical durability 3,000 cycles
Power loss at rated operating conditions 37 W per pole
Dimensions (W × H × D) 210 × 268 × 178 mm
Net weight 11 kg
Standard IEC
Application Low-voltage power distribution protection

Frequently Asked Questions

What is the ABB 1SDA101375R1 used for?

The ABB 1SDA101375R1 is a 1000 A three-pole moulded-case circuit breaker designed to protect low-voltage power distribution circuits against overloads, short circuits and ground faults.

What is the rated current of the XT7S M 1000?

The XT7S M 1000 has a rated current of 1000 A, making it suitable for high-current industrial and commercial power distribution applications.

What protection does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG.

What is the rated operational voltage of the ABB 1SDA101375R1?

The circuit breaker is designed for rated operational voltages up to 690 V AC.

How is the ABB XT7S M 1000 installed?

This version has a fixed three-pole configuration with front terminals and is designed for installation in low-voltage switchboards, distribution panels and industrial power systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded-case circuit breakers are widely used by electrical engineers, panel builders and industrial operators to provide dependable switching, circuit protection and power distribution in demanding low-voltage installations.