ABB 1SDA101373R1 XT7S M 1600 Ekip Dip LSI is a 1600 A three-pole fixed moulded-case circuit breaker with electronic LSI protection, front terminals, a stored-energy operating mechanism and 50 kA breaking-capacity performance at 415 V AC.

SKU: 1SDA101373R1MPN: 1SDA101373R1
Price
List Price £6,097.77 ex VAT
Your Price (ex VAT) Save 25%
£4,573.33 25% OFF
You save £1,524.44 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,573.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,573.33

Why Choose the ABB XT7S M 1600 Ekip Dip LSI In=1600A 3p F F Circuit Breaker?

The ABB 1SDA101373R1, designated XT7S M 1600 Ekip Dip LSI In=1600A 3p F F, is a high-performance three-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT7 M range, it combines a 1600 A rated current with an Ekip Dip LSI solid-state electronic trip unit and a stored-energy operating mechanism.

The Ekip Dip LSI electronic trip unit provides long-time overload, selective short-time and instantaneous short-circuit protection. The LSI protection architecture is particularly useful in distribution systems where selective coordination between upstream and downstream protective devices is required, helping isolate electrical faults while maintaining continuity in unaffected sections of the installation.

The XT7S M version belongs to ABB's 50 kA performance class at 415 V AC. Its fixed three-pole construction, front terminals and stored-energy operating mechanism make the 1SDA101373R1 well suited to high-current industrial switchboards, major distribution feeders and installations requiring advanced or remotely controlled switching.

Key Advantages

  • High-performance ABB SACE Tmax XT7S M moulded-case circuit breaker.
  • 1600 A rated current for demanding high-current distribution systems.
  • 50 kA XT7S performance class at 415 V AC.
  • Ekip Dip LSI electronic trip unit with long-time, selective short-time and instantaneous protection.
  • LSI functionality supports effective selectivity and protection coordination throughout electrical distribution networks.
  • Three-pole configuration for three-phase electrical systems.
  • Fixed construction with front terminals for switchboard integration.
  • Stored-energy operating mechanism supports enhanced switching and automation applications.

Key Features

  • ABB SACE Tmax XT7S M series.
  • 1600 A rated current (In).
  • Three-pole construction.
  • Ekip Dip LSI solid-state electronic trip unit.
  • Long-time overload protection.
  • Selective short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 50 kA Icu class at 415 V AC.
  • Fixed installation with front terminal connections.
  • Stored-energy operating mechanism for enhanced switching functionality.

Selective Protection and Advanced Switching for High-Current Distribution

Moulded-case circuit breakers such as the ABB XT7S M protect low-voltage installations against overloads and short circuits while providing dependable switching and isolation. The Ekip Dip LSI electronic trip unit combines long-time, selective short-time and instantaneous protection functions, giving electrical engineers the flexibility required to coordinate protection across high-current industrial distribution systems.

The XT7 M platform incorporates a stored-energy operating mechanism designed for applications requiring enhanced switching functionality. When combined with suitable ABB accessories, the breaker can form part of remotely controlled and automated power distribution systems, making it suitable for sophisticated switchboards, power management installations and critical high-current feeders.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and outgoing power distribution circuits.
  • Transformer and generator protection applications.
  • Transformer secondary distribution systems.
  • High-current three-phase feeder protection.
  • Manufacturing and process industry electrical installations.
  • Distribution systems requiring selective short-circuit protection.

Technical Specifications

Series SACE Tmax XT
ABB product group T-Max XT 250 Range
Order code / MPN 1SDA101373R1
EAN / GTIN 8056221011914
Product type Moulded-case circuit breaker (MCCB)
Frame size XT7M
Performance level XT7S
Rated current (In) 1600 A
Number of poles 3
Trip unit Ekip Dip LSI
Trip unit technology Solid-state electronic
Protection functions Long-time, selective short-time and instantaneous (LSI)
Long-time protection current range 640–1600 A
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Interruption rating S
Installation Fixed
Terminal arrangement Front terminals (F)
Operating mechanism Stored-energy mechanism
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA101373R1 used for?

The ABB 1SDA101373R1 is a 1600 A three-pole moulded-case circuit breaker designed for protection and switching in demanding low-voltage power distribution systems where electronic LSI protection and stored-energy switching functionality are required.

What current rating does the ABB XT7S M 1600 support?

The ABB XT7S M 1600 has a rated current of 1600 A, with the Ekip Dip trip unit providing a long-time protection range extending down to 640 A.

What is the breaking capacity of the ABB XT7S M 1600?

The ABB 1SDA101373R1 belongs to the XT7S 50 kA performance class at 415 V AC, providing substantial short-circuit interruption capability for demanding low-voltage distribution installations.

What protection functions are included with the Ekip Dip LSI trip unit?

The Ekip Dip LSI electronic trip unit provides long-time overload, selective short-time and instantaneous short-circuit protection, supporting effective protection coordination and selectivity within low-voltage distribution systems.

How is the ABB 1SDA101373R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Tmax XT moulded-case circuit breakers are engineered for demanding low-voltage power distribution applications where dependable electronic circuit protection, selective fault management and flexible switching functionality are essential.