1SDA101367R1 ABB XT7S M 1000 Ekip Dip LS/I In1000A 3p F F Circuit Breaker

1SDA101367R1 ABB XT7S M 1000 Ekip Dip LS/I In1000A 3p F F Circuit Breaker

ABB 1SDA101367R1 XT7S M 1000 Ekip Dip LS/I is a 1000 A three-pole fixed moulded-case circuit breaker with adjustable electronic LS/I protection, a stored-energy operating mechanism and 50 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA101367R1MPN: 1SDA101367R1
Price
List Price £3,332.20 ex VAT
Your Price (ex VAT) Save 25%
£2,499.15 25% OFF
You save £833.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,499.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,499.15

Why Choose the ABB XT7S M 1000 Ekip Dip LS/I In1000A 3p F F Circuit Breaker?

The ABB 1SDA101367R1, designated XT7S M 1000 Ekip Dip LS/I In1000A 3p F F, is a high-performance three-pole moulded-case circuit breaker (MCCB) designed for reliable protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB SACE Tmax XT7 M range, it combines a 1000 A rated current with an Ekip Dip LS/I solid-state electronic trip unit and a stored-energy operating mechanism.

The circuit breaker incorporates an Ekip Dip LS/I electronic trip unit, providing long-time overload protection together with configurable short-circuit protection. Its long-time protection threshold is adjustable from 0.4–1 × In, while the short-circuit protection threshold is adjustable from 1–10 × In, allowing protection settings to be coordinated with the characteristics of the connected electrical installation.

With a rated operational voltage of 690 V AC and a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC, the XT7S M 1000 is engineered for demanding industrial power distribution. Its fixed three-pole construction, front terminals and stored-energy operating mechanism make it suitable for integration into switchboards requiring high-current protection and enhanced switching functionality.

Key Advantages

  • High-performance ABB SACE Tmax XT7S M moulded-case circuit breaker.
  • 1000 A rated current for high-current low-voltage distribution systems.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Ekip Dip LS/I electronic trip unit with configurable overload and short-circuit protection.
  • 0.4–1 × In long-time protection adjustment for flexible overload protection.
  • 1–10 × In short-circuit protection adjustment for application-specific coordination.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Stored-energy operating mechanism supports enhanced switching and automation applications.

Key Features

  • ABB SACE Tmax XT7S M series.
  • 1000 A rated current (In).
  • Three-pole construction.
  • Ekip Dip LS/I solid-state electronic trip unit.
  • Long-time overload and configurable short-circuit protection.
  • 400–1000 A long-time protection adjustment range.
  • 1000–10000 A short-circuit protection adjustment range.
  • 50 kA Icu at 415 V AC.
  • 690 V AC rated operational voltage.
  • Fixed installation with front terminals and stored-energy operating mechanism.

Advanced Protection and Switching for Power Distribution

Moulded-case circuit breakers such as the ABB XT7S M protect low-voltage electrical installations against overloads and short circuits while providing reliable circuit switching and isolation. The adjustable Ekip Dip LS/I electronic trip unit enables protection thresholds to be matched to the connected circuit, helping engineers achieve effective protection coordination across industrial power distribution systems.

The XT7 M platform incorporates a stored-energy operating mechanism and is designed for installations requiring enhanced switching functionality. Combined with suitable accessories, the platform can support remote and automated switching applications, making it well suited to modern industrial switchboards and power management systems.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and outgoing power distribution circuits.
  • Transformer secondary distribution systems.
  • Manufacturing and process industry electrical installations.
  • Motorised and remotely operated switching applications.
  • Commercial and infrastructure power distribution.
  • High-current three-phase feeder and distribution circuits.

Technical Specifications

Series SACE Tmax XT7 M
ABB product group T-Max XT 250 Range
Order code / MPN 1SDA101367R1
Product type Moulded-case circuit breaker (MCCB)
Frame size XT7M
Performance level XT7S
Rated current (In) 1000 A
Rated operational voltage 690 V AC
Number of poles 3
Trip unit Ekip Dip LS/I
Trip unit technology Solid-state electronic
Protection functions Long-time and short-circuit protection (LS/I)
Long-time protection adjustment 0.4–1 × In
Long-time protection current range 400–1000 A
Short-circuit protection adjustment 1–10 × In
Short-circuit protection current range 1000–10000 A
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Interruption rating S
Installation Fixed
Terminal arrangement Front terminals (F)
Operating mechanism Stored-energy mechanism
Standard IEC
EAN / GTIN 8056221011853

Frequently Asked Questions

What is the ABB 1SDA101367R1 used for?

The ABB 1SDA101367R1 is a 1000 A three-pole moulded-case circuit breaker designed for protection and switching in demanding low-voltage power distribution systems, including applications requiring stored-energy switching functionality.

What current rating does the ABB XT7S M 1000 support?

This circuit breaker has a rated current of 1000 A, with long-time overload protection adjustable from 400–1000 A.

What is the breaking capacity of the ABB XT7S M 1000?

The ABB 1SDA101367R1 has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC, corresponding to the S performance level of the XT7 platform.

What protection functions are included with the Ekip Dip LS/I trip unit?

The Ekip Dip LS/I electronic trip unit provides long-time overload and configurable short-circuit protection, with adjustable thresholds for coordination with the electrical installation.

How is the ABB 1SDA101367R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Tmax XT moulded-case circuit breakers are designed for demanding low-voltage power distribution applications where dependable electronic circuit protection, high breaking performance and flexible switching functionality are essential.