ABB 1SDA101278R1 XT7L 800 Ekip Dip LIG is an 800 A four-pole fixed moulded-case circuit breaker with electronic LIG protection, a 690 V AC rated operational voltage and 120 kA ultimate breaking capacity at 415 V AC.
£4,803.74
The ABB 1SDA101278R1, designated XT7L 800 Ekip Dip LIG In=800A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for reliable protection and switching in demanding low-voltage power distribution systems. As part of the ABB SACE Tmax XT range, it combines an 800 A rated current with an Ekip Dip LIG solid-state electronic trip unit.
The circuit breaker incorporates an Ekip Dip LIG electronic release, providing long-time overload, instantaneous short-circuit and ground-fault protection. This combination makes the XT7L suitable for power distribution, transformer and generator installations where dependable electronic protection and high fault-breaking performance are required.
With a rated operational voltage of 690 V AC and a rated ultimate short-circuit breaking capacity of 120 kA at 415 V AC, the XT7L 800 provides robust protection for demanding industrial electrical systems. Its fixed four-pole construction, front terminals and lever operating mechanism enable straightforward integration into low-voltage switchboards and distribution assemblies.
Moulded-case circuit breakers such as the ABB XT7L protect low-voltage electrical systems against damaging overcurrents and fault conditions while providing dependable circuit switching and isolation. The high breaking capacities available from the XT7L platform make it particularly suitable for industrial installations where prospective short-circuit currents can be substantial.
The Ekip Dip LIG electronic release combines long-time overload, instantaneous short-circuit and ground-fault protection in a robust electronic protection system. Together with the XT7L's high interruption performance and four-pole construction, this provides an effective solution for protecting power distribution, transformer and generator circuits.
| Series | SACE Tmax XT7L |
|---|---|
| ABB product group | T-Max XT 250 Range |
| Order code / MPN | 1SDA101278R1 |
| Product type | Moulded-case circuit breaker (MCCB) |
| Frame | XT7 |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Number of poles | 4 |
| Trip unit | Ekip Dip LIG |
| Release type | Electronic (EL) |
| Protection functions | Long-time, instantaneous and ground fault (LIG) |
| Rated ultimate breaking capacity (Icu) at 220–240 V AC | 200 kA |
| Rated ultimate breaking capacity (Icu) at 380–415 V AC | 120 kA |
| Rated ultimate breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated ultimate breaking capacity (Icu) at 500 V AC | 85 kA |
| Rated ultimate breaking capacity (Icu) at 525 V AC | 65 kA |
| Rated ultimate breaking capacity (Icu) at 690 V AC | 50 kA |
| Rated short-time withstand current (Icw) | 20 kA |
| Short-circuit performance level | L |
| Installation | Fixed |
| Terminal connection | Front |
| Operating mechanism | Lever operated |
| Standard | IEC 60947-2 |
| Electrical durability | 3000 cycles |
| Mechanical durability | 10000 cycles |
| Power loss at rated operating conditions | 24 W per pole |
| Dimensions (W × H × D) | 280 × 268 × 166 mm |
| Net weight | 12.5 kg |
| EAN | 8056221010962 |
The ABB 1SDA101278R1 is an 800 A four-pole moulded-case circuit breaker designed for protection and switching in industrial power distribution, transformer and generator applications.
This circuit breaker has a rated current and rated uninterrupted current of 800 A, making it suitable for high-current low-voltage distribution systems.
The 1SDA101278R1 has a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacities ranging from 200 kA at 220–240 V AC to 50 kA at 690 V AC.
The Ekip Dip LIG electronic trip unit provides long-time overload, instantaneous short-circuit and ground-fault protection for the connected electrical system.
This model is a fixed four-pole circuit breaker with front terminals and a lever operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.
ABB SACE Tmax XT moulded-case circuit breakers are designed for demanding low-voltage power distribution applications where reliable circuit protection, high breaking performance and robust electronic trip technology are essential.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.