Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA101267R1 XT7L 1000 is a fixed four-pole 1000 A moulded case circuit breaker with front terminals, XT7L 120 kA breaking-capacity class and an Ekip G Touch LSIG electronic trip unit for advanced generator, transformer and low-voltage circuit protection.
£9,547.49
The ABB 1SDA101267R1 is a high-performance SACE Tmax XT moulded case circuit breaker (MCCB) designed for generator, transformer and installation protection in demanding low-voltage electrical distribution systems. Identified as XT7L 1000 Ekip G Touch LSIG In=1000A 4p F F, this four-pole circuit breaker combines fixed construction, front terminals and ABB's advanced Ekip G Touch LSIG electronic trip unit.
As part of the ABB SACE Tmax XT7 range, the breaker uses the Ekip G Touch platform for advanced generator protection. Its LSIG electronic protection functions provide long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault functionality, supporting sophisticated protection and coordination requirements in generator-fed and conventional low-voltage distribution systems.
With a rated uninterrupted current of 1000 A, rated voltage of 690 V and the high-breaking-capacity XT7L 120 kA class, the 1SDA101267R1 is well suited to generator systems, industrial switchboards, critical power installations and high-capacity distribution feeders. Its fixed four-pole construction with front terminals provides practical integration into low-voltage switchgear and generator control assemblies.
Generator circuit breakers protect generating equipment and associated distribution networks against abnormal current and fault conditions while providing reliable switching and isolation. Generator-fed systems can exhibit different fault-current characteristics from utility-fed networks, making appropriately configured electronic protection particularly important for dependable operation and equipment protection.
ABB's Ekip G Touch LSIG electronic trip unit combines long-time, short-time, instantaneous and ground-fault functionality within an advanced electronic protection platform. When paired with the high-breaking-capacity XT7L platform, it provides a robust solution for generator feeders, standby power systems, transformer circuits, industrial plants and other critical low-voltage distribution applications.
| Series | SACE Tmax XT |
|---|---|
| Frame size | XT7 |
| Order code / MPN | 1SDA101267R1 |
| Product group | T-Max XT 250 Range |
| Product type | Moulded case circuit breaker (MCCB) |
| Primary application | Generator, transformer and installation protection |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated current (In) | 1000 A |
| Rated voltage | 690 V |
| Number of poles | 4 |
| Trip unit | Ekip G Touch LSIG |
| Trip unit technology | Electronic |
| Protection functions | Long-time, short-time, instantaneous and ground-fault functionality (LSIG) |
| Overload release current setting | 400–1000 A |
| Short-time delayed short-circuit setting | 600–10000 A |
| Instantaneous short-circuit setting | 1500–15000 A |
| Interruption rating | L |
| Breaking-capacity class | 120 kA |
| Power loss | 37 W |
| Mounting type | Fixed |
| Terminal position | Front |
| Main circuit connection | Bolted connection |
| Operating mechanism | Lever / toggle |
| Integrated motor drive | No |
| Motor drive | Optional |
| DIN rail mounting | No |
| Protection rating | IP20 |
| EAN | 8056221010856 |
The ABB 1SDA101267R1 is a four-pole moulded case circuit breaker equipped with an Ekip G Touch LSIG electronic trip unit, making it particularly suitable for generator, transformer and demanding low-voltage installation protection applications.
The XT7L 1000 has a rated uninterrupted current of 1000 A, making it suitable for high-current generator and low-voltage power distribution circuits.
The Ekip G Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault functionality for advanced protection of generators and associated electrical distribution circuits.
The ABB XT7L version belongs to the 120 kA breaking-capacity class, providing high fault-interruption performance for demanding generator and electrical distribution installations.
The 1SDA101267R1 is a fixed four-pole circuit breaker with front terminals and a lever / toggle operating mechanism, designed for installation within low-voltage switchboards, generator panels and industrial electrical assemblies.
ABB SACE Tmax XT circuit breakers provide dependable low-voltage circuit protection for generator, transformer, industrial and infrastructure applications, combining advanced electronic trip technology, high breaking performance and flexible integration into modern electrical distribution systems.