1SDA101213R1 ABB XT7H 1600 Ekip G Touch LSIG 1600A 4 Pole Generator MCCB

1SDA101213R1 ABB XT7H 1600 Ekip G Touch LSIG 1600A 4 Pole Generator MCCB

ABB 1SDA101213R1 XT7H 1600 is a 1600 A four-pole fixed moulded case circuit breaker with an Ekip G Touch LSIG electronic trip unit for advanced generator protection and a 70 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA101213R1MPN: 1SDA101213R1
Price
List Price £13,654.19 ex VAT
Your Price (ex VAT) Save 25%
£10,240.64 25% OFF
You save £3,413.55 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,240.64
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,240.64

Why Choose the ABB XT7H 1600 Ekip G Touch LSIG 1SDA101213R1 Circuit Breaker?

The ABB 1SDA101213R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for advanced generator protection and switching in demanding low-voltage AC electrical systems. Identified by ABB as the XT7H 1600 Ekip G Touch LSIG In1600 4p FF, it combines the robust SACE Tmax XT7 platform with ABB’s generator-oriented Ekip G Touch LSIG electronic trip unit for industrial, commercial and infrastructure power installations.

This fixed circuit breaker features the Ekip G Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions for generator and power distribution applications. The advanced touch-interface release supports precise electronic protection and system supervision, helping engineers coordinate protection throughout generator switchboards and associated low-voltage distribution systems.

With a rated uninterrupted current of 1600 A and an XT7H ultimate short-circuit breaking capacity of 70 kA at 415 V AC, the 1SDA101213R1 is engineered for high-current generator and distribution circuits with demanding fault-current requirements. Its fixed four-pole construction and front terminals support straightforward integration into generator switchboards and low-voltage power distribution assemblies.

Key Advantages

  • Advanced four-pole moulded case circuit breaker for generator and power distribution applications.
  • 1600 A rated uninterrupted current for high-current electrical systems.
  • Generator-oriented Ekip G Touch LSIG electronic trip unit.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • 70 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Advanced electronic protection supports precise settings, selectivity and system coordination.
  • Touch-interface trip technology supports advanced protection and system supervision.
  • Four-pole configuration supports three-phase systems incorporating a neutral conductor.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT7H moulded case circuit breaker.
  • Designed for generator protection applications.
  • 1600 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip G Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • H interruption rating.
  • 70 kA Icu at 415 V AC.
  • Fixed installation with front terminal connections.
  • Designed for AC low-voltage generator and power distribution systems.

Advanced Generator Protection for Low-Voltage Power Systems

Generator circuits require protection characteristics suited to the operating behaviour and available fault current of generating equipment. The ABB XT7H 1600 with Ekip G Touch LSIG combines generator-oriented electronic protection with the high interruption performance of the SACE Tmax XT7H platform, helping protect generators and associated low-voltage distribution circuits against overload, short-circuit and ground-fault conditions.

The Ekip G Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection through an advanced electronic interface. Combined with a 1600 A rated uninterrupted current, 70 kA Icu at 415 V AC and four-pole construction, the 1SDA101213R1 is particularly suitable for generator incomers, standby power systems and other applications where comprehensive high-current circuit protection is required.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator main circuit breakers.
  • Standby and emergency power systems.
  • Generator switchboards and control panels.
  • Industrial low-voltage power distribution systems.
  • Commercial and infrastructure backup power installations.
  • High-current generator feeder protection.

Technical Specifications

Product group T-Max XT 250 Range
Series SACE Tmax XT
Order code 1SDA101213R1
EAN / GTIN 8056221015165
Product type Moulded case circuit breaker (MCCB)
Application Generator protection and low-voltage power distribution
Frame size XT7
Performance level H
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Trip unit Ekip G Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Number of poles 4
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Installation Fixed
Terminal connection Front terminals
Configuration 4p FF
Product weight 14 kg

Frequently Asked Questions

What is the ABB 1SDA101213R1 used for?

The ABB 1SDA101213R1 is a four-pole moulded case circuit breaker equipped with a generator-oriented Ekip G Touch LSIG electronic trip unit for protecting and switching high-current low-voltage generator and distribution circuits.

What is the rated current of the ABB XT7H 1600?

The ABB 1SDA101213R1 has a rated uninterrupted current of 1600 A, making it suitable for high-current generator incomers, feeders and power distribution applications.

What trip unit is fitted to the ABB 1SDA101213R1?

The breaker is fitted with an Ekip G Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions for generator and distribution applications.

What is the breaking capacity of the ABB XT7H 1600?

The XT7H version provides an ultimate short-circuit breaking capacity of 70 kA at 415 V AC, making it suitable for demanding low-voltage systems with substantial prospective fault currents.

How is the ABB 1SDA101213R1 installed?

The 1SDA101213R1 is a fixed four-pole circuit breaker with front terminals, designed for integration into generator switchboards and low-voltage power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in generator, industrial and commercial power systems to provide dependable circuit protection, advanced electronic trip functionality and high short-circuit performance for modern low-voltage installations.