1SDA101208R1 ABB XT7H 1250 Ekip G Dip LS/I 1250A 4 Pole Generator MCCB

1SDA101208R1 ABB XT7H 1250 Ekip G Dip LS/I 1250A 4 Pole Generator MCCB

ABB 1SDA101208R1 XT7H 1250 is a 1250 A four-pole fixed generator-protection moulded case circuit breaker with an Ekip G Dip LS/I electronic trip unit and a 70 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA101208R1MPN: 1SDA101208R1
Price
List Price £6,118.14 ex VAT
Your Price (ex VAT) Save 25%
£4,588.61 25% OFF
You save £1,529.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,588.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,588.61

Why Choose the ABB XT7H 1250 Ekip G Dip LS/I 1SDA101208R1 Circuit Breaker?

The ABB 1SDA101208R1 is a high-performance four-pole moulded case circuit breaker (MCCB) specifically configured for generator protection in demanding low-voltage AC electrical systems. Identified by ABB as the XT7H 1250 Ekip G Dip LS/I In1250A 4p F F, it combines the robust SACE Tmax XT7 platform with ABB’s Ekip G Dip LS/I electronic trip unit for industrial, commercial and infrastructure power installations.

This fixed circuit breaker features the Ekip G Dip LS/I electronic trip unit, designed for generator applications and providing long-time, short-time and instantaneous protection functions. The generator-specific electronic release allows appropriate protection of generating equipment and associated distribution circuits while the XT7H platform provides high short-circuit interruption performance.

With a rated uninterrupted current of 1250 A, a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 70 kA at 415 V AC, the XT7H 1250 is engineered for high-current generator and distribution applications. Its fixed four-pole construction, front connections and toggle operating mechanism support straightforward integration into generator switchboards and low-voltage distribution assemblies.

Key Advantages

  • Generator-protection four-pole moulded case circuit breaker for demanding low-voltage applications.
  • 1250 A rated uninterrupted current for high-current generator and distribution circuits.
  • Dedicated Ekip G Dip LS/I electronic trip unit.
  • Long-time, short-time and instantaneous protection functions.
  • 70 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • 690 V AC rated operational voltage for low-voltage power systems.
  • 20 kA rated short-time withstand current.
  • Four-pole configuration for three-phase systems incorporating a neutral conductor.
  • Fixed construction with front connections for switchboard integration.

Key Features

  • ABB SACE Tmax XT7H moulded case circuit breaker.
  • Designed for generator protection.
  • 1250 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip G Dip LS/I electronic release.
  • Long-time, short-time and instantaneous protection functions.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 20 kA rated short-time withstand current.
  • H short-circuit performance level with 70 kA Icu at 415 V AC.
  • Fixed installation with front main-circuit connections.
  • Optional motor operating mechanism compatibility.

Generator Protection for Low-Voltage Power Systems

Generator circuits require protection characteristics suited to the operating behaviour and fault-current capability of generating equipment. The ABB XT7H 1250 with Ekip G Dip LS/I combines generator-oriented electronic protection with the high interruption performance of the SACE Tmax XT7H platform, helping protect generators and their associated low-voltage distribution circuits against overload and short-circuit conditions.

The Ekip G Dip LS/I release provides long-time, short-time and instantaneous protection while the breaker’s 70 kA Icu at 415 V AC and 20 kA short-time withstand capability support demanding generator switchboard applications. Its four-pole fixed configuration is particularly suitable for three-phase generator systems where switching and protection of the neutral conductor are required.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator main circuit breakers.
  • Standby and emergency power systems.
  • Generator switchboards and control panels.
  • Industrial low-voltage power distribution systems.
  • Commercial and infrastructure backup power installations.
  • High-current generator feeder protection.

Technical Specifications

Product group T-Max XT 250 Range
Series SACE Tmax XT
Order code 1SDA101208R1
Product type Moulded case circuit breaker (MCCB)
Application Generator protection
Frame size XT7
Performance level H
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Trip unit Ekip G Dip LS/I
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LS/I)
Integrated earth-fault protection No
Number of poles 4
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 220–240 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 70 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 70 kA
Rated short-time withstand current (Icw) 20 kA
Overload release current setting 1250 A
Short-time delayed short-circuit release setting 12500 A
Installation Fixed
Main circuit connection Bolt connection
Connection position Front
Operating element Toggle
Motor drive Optional
Degree of protection IP20

Frequently Asked Questions

What is the ABB 1SDA101208R1 used for?

The ABB 1SDA101208R1 is a four-pole moulded case circuit breaker configured for generator protection, providing electronic overload and short-circuit protection for low-voltage generating systems and associated distribution circuits.

What is the rated current of the ABB XT7H 1250?

The circuit breaker has a rated uninterrupted current of 1250 A, making it suitable for high-current generator and distribution applications.

What trip unit is fitted to the ABB 1SDA101208R1?

The breaker is fitted with an Ekip G Dip LS/I electronic trip unit, a generator-oriented release providing long-time, short-time and instantaneous protection functions.

What is the breaking capacity of the ABB XT7H 1250?

The XT7H has an ultimate short-circuit breaking capacity of 70 kA at 415 V AC. Its Icu ratings also include 100 kA at 220–240 V AC, 65 kA at 440 V AC, 50 kA at 500–525 V AC and 42 kA at 690 V AC.

How is the ABB 1SDA101208R1 installed?

The 1SDA101208R1 is a fixed four-pole circuit breaker with front main-circuit connections, designed for integration into generator switchboards and low-voltage power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in generator, industrial and commercial power systems to provide dependable circuit protection, electronic trip functionality and high short-circuit performance for modern low-voltage installations.