1SDA101166R1 ABB XT7S 800 Ekip Dip LIG In=800A 4p F F Circuit Breaker

1SDA101166R1 ABB XT7S 800 Ekip Dip LIG In=800A 4p F F Circuit Breaker

ABB 1SDA101166R1 XT7S 800 Ekip Dip LIG four-pole fixed moulded case circuit breaker with an 800 A rated current, 50 kA breaking capacity at 400 V AC, front terminals and electronic overload, instantaneous short-circuit and ground-fault protection.

SKU: 1SDA101166R1MPN: 1SDA101166R1
Price
List Price £4,385.28 ex VAT
Your Price (ex VAT) Save 25%
£3,288.96 25% OFF
You save £1,096.32 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,288.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,288.96

Why Choose the ABB XT7S 800 Ekip Dip LIG In=800A 4p F F Circuit Breaker?

The ABB XT7S 800 Ekip Dip LIG In=800A 4p F F, order code 1SDA101166R1, is a high-performance four-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Designed for transformer, generator and installation protection, it combines an 800 A rated uninterrupted current with an Ekip Dip LIG electronic trip unit for dependable protection in demanding low-voltage distribution systems.

The Ekip Dip LIG solid-state electronic release provides overload, instantaneous short-circuit and ground-fault protection functions. Its adjustable settings enable the protection characteristics to be coordinated with the electrical installation, helping safeguard conductors, switchgear and connected equipment against damaging overcurrent and earth-fault conditions.

The XT7S version provides a rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC, 50 Hz. Its four-pole fixed construction, front terminals, bolt-connected main circuit and lever operating mechanism make the 1SDA101166R1 a practical choice for high-current switchboards and power distribution assemblies.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for low-voltage power distribution.
  • Four-pole configuration suitable for three-phase systems with neutral.
  • Ekip Dip LIG electronic trip unit with overload, instantaneous and ground-fault protection functions.
  • Adjustable overload setting from 320–800 A.
  • Adjustable instantaneous short-circuit setting from 800–8000 A.
  • 50 kA Icu at 400 V AC, 50 Hz for robust short-circuit protection.
  • Fixed installation with front terminals for straightforward switchboard integration.
  • Part of the established ABB SACE Tmax XT circuit breaker platform.

Key Features

  • ABB SACE Tmax XT7S moulded case circuit breaker.
  • 800 A rated uninterrupted current (Iu).
  • Four-pole construction.
  • Ekip Dip LIG solid-state electronic release.
  • LIG protection for overload, instantaneous short-circuit and ground-fault conditions.
  • 690 V rated voltage.
  • 50 kA rated ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • 24 W power dissipation.
  • IP20 protection rating.
  • Fixed installation with front main-circuit connections.
  • Lever operating mechanism.
  • Optional motor operator capability.

Advanced LIG Protection for Power Distribution

The ABB Ekip Dip LIG electronic trip unit combines overload protection with instantaneous short-circuit and ground-fault protection. This makes the 1SDA101166R1 particularly suitable for electrical systems where earth-fault protection is required alongside conventional overcurrent protection, while adjustable current settings support coordination with the characteristics of the protected installation.

The XT7S platform combines electronic protection with robust high-current moulded case circuit breaker construction. With its 800 A rating, four-pole design, 690 V rated voltage and 50 kA Icu at 400 V AC, the 1SDA101166R1 is suited to transformer, generator and installation protection across industrial and commercial low-voltage distribution systems.

Typical Applications

  • Industrial low-voltage switchboards.
  • Transformer protection and distribution systems.
  • Generator-fed electrical installations.
  • Main and sub-main power distribution.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical systems.
  • High-current feeders requiring electronic overcurrent protection.
  • Distribution circuits requiring integrated ground-fault protection.

Technical Specifications

Series SACE Tmax XT
Order code / Product ID 1SDA101166R1
Product type Moulded case circuit breaker (MCCB)
Frame XT7
Breaking-performance version XT7S
Rated uninterrupted current (Iu) 800 A
Rated current (In) 800 A
Number of poles 4
Trip unit Ekip Dip LIG
Release type Solid-state electronic release
Protection functions Overload, instantaneous short circuit and ground fault (LIG)
Rated voltage 690 V
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 50 kA
Overload release adjustment range 320–800 A
Instantaneous short-circuit release adjustment range 800–8000 A
Power dissipation 24 W
Protection rating IP20
Installation Fixed
Main circuit connection Bolt connection
Terminal position Front
Operating mechanism Lever
Complete device with protection unit Yes
Integrated motor operator No
Optional motor operator Yes
EAN 8056221014694

Frequently Asked Questions

What is the ABB 1SDA101166R1 used for?

The ABB 1SDA101166R1 is an 800 A four-pole moulded case circuit breaker designed for transformer, generator and installation protection in demanding low-voltage electrical distribution systems.

What is the rated current of the ABB XT7S 1SDA101166R1?

The circuit breaker has a rated uninterrupted current of 800 A, with an overload release adjustment range of 320–800 A.

Which trip unit is fitted to the ABB 1SDA101166R1?

The 1SDA101166R1 is fitted with an Ekip Dip LIG solid-state electronic trip unit providing overload, instantaneous short-circuit and ground-fault protection functions.

What is the breaking capacity of the ABB XT7S 800 1SDA101166R1?

The circuit breaker has a rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC, 50 Hz.

How is the ABB XT7S 1SDA101166R1 installed?

The 1SDA101166R1 is a fixed four-pole circuit breaker with front terminals, bolt-connected main circuit connections and a lever operating mechanism. A motor operator can be fitted as an option.

Trusted Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers combine configurable electronic protection, robust short-circuit performance and flexible installation options for dependable transformer, generator and low-voltage power distribution applications.