1SDA101153R1 ABB XT7S 1600 Ekip G Dip LS/I In1600A 4p F F Circuit Breaker

1SDA101153R1 ABB XT7S 1600 Ekip G Dip LS/I In1600A 4p F F Circuit Breaker

ABB 1SDA101153R1 XT7S 1600 Ekip G Dip LS/I four-pole fixed moulded case circuit breaker with a 1600 A rated current, front terminals and adjustable electronic protection designed for generator applications.

SKU: 1SDA101153R1MPN: 1SDA101153R1
Price
List Price £6,437.25 ex VAT
Your Price (ex VAT) Save 25%
£4,827.94 25% OFF
You save £1,609.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,827.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,827.94

Why Choose the ABB XT7S 1600 Ekip G Dip LS/I In1600A 4p F F Circuit Breaker?

The ABB XT7S 1600 Ekip G Dip LS/I In1600A 4p F F, order code 1SDA101153R1, is a high-performance four-pole moulded case circuit breaker (MCCB) engineered for generator protection and demanding low-voltage power distribution applications. Part of the ABB SACE Tmax XT series, it combines a 1600 A rated current with the Ekip G Dip LS/I electronic trip unit and the XT7S 50 kA performance level.

The Ekip G Dip LS/I solid-state release is designed for generator applications and provides adjustable long-time overload, short-time delayed and instantaneous short-circuit protection. Its electronic protection characteristics allow the circuit breaker to be coordinated with generator-fed networks while protecting conductors, switchgear and connected equipment against damaging overcurrent conditions.

With a rated uninterrupted current of 1600 A, four-pole construction and a rated operational voltage of 690 V AC, the XT7S is suitable for substantial generator and industrial distribution systems. Fixed construction, front terminals and a lever operating mechanism provide a robust configuration for integration into low-voltage switchboards and generator distribution assemblies.

Key Advantages

  • High-performance 1600 A moulded case circuit breaker for generator protection.
  • Four-pole configuration suitable for three-phase systems with neutral.
  • Purpose-designed Ekip G Dip LS/I electronic trip unit.
  • Adjustable long-time, short-time delayed and instantaneous short-circuit protection.
  • 640–1600 A overload release adjustment range.
  • 50 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • Fixed installation with front terminals for switchboard integration.
  • Part of the advanced ABB SACE Tmax XT circuit breaker platform.

Key Features

  • ABB SACE Tmax XT7S moulded case circuit breaker.
  • 1600 A rated uninterrupted current.
  • Four-pole construction.
  • Ekip G Dip LS/I solid-state electronic release.
  • Designed for generator protection applications.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 20 kA rated short-time withstand current.
  • 50 kA Icu at 415 V AC.
  • IP20 protection rating.
  • Fixed installation with front main-circuit connections.

Advanced Protection for Generator Applications

Generator-fed electrical systems require carefully coordinated protection because their fault-current characteristics can differ from conventional utility-fed networks. The ABB Ekip G Dip LS/I trip unit is intended for generator protection, providing adjustable long-time overload, short-time delayed and instantaneous short-circuit functions that allow the protective response to be matched to the generator and associated electrical installation.

The XT7S platform combines this generator-focused electronic protection with robust high-current circuit breaker performance. With its 1600 A rating, four-pole construction, 690 V AC operational voltage and 50 kA Icu at 415 V AC, the 1SDA101153R1 is well suited to generator switchboards, standby power systems and demanding industrial power distribution applications.

Typical Applications

  • Generator protection systems.
  • Generator control and distribution switchboards.
  • Standby and emergency power installations.
  • Industrial low-voltage switchboards.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • High-current generator feeders.
  • Electrical systems requiring adjustable electronic overcurrent protection.

Technical Specifications

Series SACE Tmax XT
Order code / Product ID 1SDA101153R1
Product type Moulded case circuit breaker (MCCB)
Frame XT7
Application Generator protection
Rated uninterrupted current (Iu) 1600 A
Rated current (In) 1600 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Release type Electronic (EL)
Protection functions Long-time, short-time and instantaneous (LS/I)
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated short-time withstand current (Icw) 20 kA
Rated ultimate short-circuit breaking capacity (Icu) at 380–440 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 45 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 30 kA
Overload release adjustment range 640–1600 A
Short-time delayed short-circuit release adjustment range 960–16000 A
Instantaneous short-circuit release adjustment range 1600–16000 A
Integrated earth-fault protection No
Short-circuit performance level S
Protection rating IP20
Power loss at rated operating conditions per pole 94 W
Electrical durability 3000 cycles
Mechanical durability 10000 cycles
Installation Fixed
Main circuit connection Bolt connection
Terminal position Front
Operating mechanism Lever
Optional motor operator Yes
Standard IEC 60947-2
EAN 8056221014564

Frequently Asked Questions

What is the ABB 1SDA101153R1 used for?

The ABB 1SDA101153R1 is a 1600 A four-pole moulded case circuit breaker equipped with an Ekip G Dip LS/I electronic trip unit for generator protection and demanding low-voltage electrical distribution applications.

What is the rated current of the ABB XT7S 1SDA101153R1?

The circuit breaker has a rated uninterrupted current and rated trip-unit current of 1600 A.

Which trip unit is fitted to the ABB 1SDA101153R1?

The 1SDA101153R1 is fitted with an Ekip G Dip LS/I electronic trip unit designed for generator protection, with adjustable long-time overload, short-time delayed and instantaneous short-circuit protection.

What is the breaking capacity of the ABB XT7S 1600?

The XT7S 1SDA101153R1 has a rated ultimate short-circuit breaking capacity of 50 kA at 380–440 V AC, reducing to 45 kA at 500–525 V AC and 30 kA at 690 V AC.

How is the ABB XT7S 1SDA101153R1 installed?

The 1SDA101153R1 is a fixed four-pole circuit breaker with front terminals, bolt-connected main circuit connections and a lever operating mechanism, designed for integration into low-voltage switchboards and generator distribution assemblies.

Trusted Generator Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers with Ekip G electronic protection combine configurable generator protection, high short-circuit performance and robust construction for demanding industrial and commercial low-voltage power systems.