1SDA101136R1 ABB XT7S 1250 Ekip Touch Measuring LSI 1250A 4-Pole Circuit Breaker

1SDA101136R1 ABB XT7S 1250 Ekip Touch Measuring LSI 1250A 4-Pole Circuit Breaker

ABB 1SDA101136R1 is an XT7S 1250 A four-pole fixed moulded case circuit breaker with front terminals and an Ekip Touch Measuring LSI electronic trip unit for advanced protection and electrical measurement in high-current low-voltage power distribution systems.

SKU: 1SDA101136R1MPN: 1SDA101136R1
Price
List Price £6,497.49 ex VAT
Your Price (ex VAT) Save 25%
£4,873.12 25% OFF
You save £1,624.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,873.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,873.12

Why Choose the ABB 1SDA101136R1 XT7S 1250 Circuit Breaker?

The ABB 1SDA101136R1 is a high-performance SACE Tmax XT7S moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution applications. Configured as an XT7S 1250 Ekip Touch Meas.LSI 1250 4p FF, it combines a 1250 A rated current with ABB's advanced Ekip Touch Measuring LSI electronic trip unit and the robust protection capabilities of the XT7 platform.

The Ekip Touch Measuring LSI release provides long-time, short-time and instantaneous protection functions together with integrated electrical measurement capabilities. This combination enables advanced circuit protection and access to useful electrical data, supporting effective system supervision, protection coordination and energy management in modern low-voltage installations.

This XT7S version carries ABB's S short-circuit performance designation and provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC. Its four-pole fixed configuration with front terminals makes it suitable for integration into high-current industrial, commercial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Tmax XT7S moulded case circuit breaker.
  • 1250 A rated current for demanding high-current distribution systems.
  • Ekip Touch Measuring LSI electronic trip unit combining protection and electrical measurement capabilities.
  • Long-time, short-time and instantaneous protection functions.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Four-pole fixed construction with front terminals for practical switchboard integration.

Key Features

  • ABB SACE Tmax XT7S series.
  • 1250 A rated current.
  • Ekip Touch Measuring LSI electronic release.
  • Integrated electrical measurement functionality.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Long-time protection setting range of 0.4–1 × In.
  • Short-circuit protection setting range of 1–10 × In.
  • Four-pole configuration.
  • Fixed construction with front terminal connections.
  • S performance level with 50 kA breaking capacity at 415 V AC.

Advanced Protection and Measurement for Power Distribution

The ABB Ekip Touch Measuring platform extends conventional circuit protection by combining electronic protection functions with electrical measurement capabilities. In the 1SDA101136R1, the LSI protection functions provide long-time overload, short-time selective and instantaneous short-circuit protection, helping safeguard cables, switchgear and connected equipment against damaging electrical conditions.

Integrated measurement functionality also makes the XT7S particularly useful in modern power distribution systems where operators require greater visibility of electrical conditions alongside dependable circuit protection. Combined with the 1250 A rating, four-pole architecture and 50 kA breaking capacity at 415 V AC, this makes the breaker well suited to sophisticated high-current switchboards and distribution assemblies.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main electrical distribution panels.
  • Four-pole three-phase distribution systems.
  • High-current electrical distribution networks.
  • Power distribution systems requiring integrated electrical measurement.
  • Transformer and installation protection.
  • Industrial plants and manufacturing facilities.
  • Commercial and infrastructure power distribution installations.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101136R1
Product type Moulded case circuit breaker
Frame size XT7
Rated current 1250 A
Trip unit Ekip Touch Measuring LSI
Release type Solid-state electronic release
Protection functions Long-time, short-time and instantaneous
Measurement functionality Integrated electrical measuring functions
Long-time protection setting 0.4–1 × In
Short-circuit protection setting 1–10 × In
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Performance level S
Number of poles 4
Version Fixed
Terminal connection Front terminals
Operating mechanism Lever
Standard IEC
EAN 8056221014397

Frequently Asked Questions

What is the ABB 1SDA101136R1 used for?

The ABB 1SDA101136R1 is an XT7S moulded case circuit breaker for high-current low-voltage power distribution, combining advanced LSI electronic protection with integrated electrical measurement functionality.

What is the rated current of the ABB 1SDA101136R1?

The circuit breaker has a rated current of 1250 A, making it suitable for demanding high-current power distribution applications.

What protection unit is fitted to the ABB 1SDA101136R1?

The circuit breaker is fitted with an Ekip Touch Measuring LSI electronic trip unit, providing long-time, short-time and instantaneous protection together with integrated electrical measurement capabilities.

What is the breaking capacity of the ABB XT7S 1250?

This XT7S version has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC and carries ABB's S short-circuit performance designation.

How is the ABB 1SDA101136R1 installed?

The 1SDA101136R1 is a fixed four-pole circuit breaker with front terminals and a lever operating mechanism, designed for integration into low-voltage switchboards and high-current power distribution assemblies.

Trusted Protection from ABB

ABB SACE Tmax XT circuit breakers combine advanced electronic protection, integrated measurement capabilities and robust short-circuit performance for demanding industrial, commercial and infrastructure low-voltage power distribution applications.