1SDA101009R1 ABB XT7L 1600 Ekip G Hi-Touch LSIG 1600A 3-Pole Circuit Breaker

1SDA101009R1 ABB XT7L 1600 Ekip G Hi-Touch LSIG 1600A 3-Pole Circuit Breaker

ABB 1SDA101009R1 is an XT7L 1600 A three-pole fixed moulded case circuit breaker with front terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator and low-voltage power distribution protection.

SKU: 1SDA101009R1MPN: 1SDA101009R1
Price
List Price £12,354.13 ex VAT
Your Price (ex VAT) Save 25%
£9,265.60 25% OFF
You save £3,088.53 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,265.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,265.60

Why Choose the ABB 1SDA101009R1 XT7L 1600 Circuit Breaker?

The ABB 1SDA101009R1 is a high-performance SACE Tmax XT7L moulded case circuit breaker (MCCB) designed for generator protection and demanding low-voltage electrical distribution applications. Configured as an XT7L 1600 Ekip G Hi-Touch LSIG In=1600A 3p F F, it combines a 1600 A rated current with ABB's advanced Ekip G Hi-Touch LSIG electronic trip unit and high short-circuit breaking performance.

As part of the advanced ABB SACE Tmax XT range, this circuit breaker provides sophisticated electronic protection for generators and low-voltage distribution systems. The Ekip G Hi-Touch LSIG solid-state release provides long-time, short-time, instantaneous and ground-fault protection functions, supporting comprehensive protection and flexible configuration in demanding electrical installations.

With a rated uninterrupted current of 1600 A and an XT7L short-circuit breaking performance of 120 kA, the 1SDA101009R1 is engineered for high-current installations requiring dependable fault interruption. Its three-pole fixed configuration with front terminals and lever operating mechanism enable straightforward integration into generator panels, industrial switchboards and power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded case circuit breaker.
  • 1600 A rated uninterrupted current for high-current electrical distribution.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for generator protection.
  • 120 kA XT7L short-circuit breaking performance.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Three-pole fixed construction with front terminals for switchboard installation.

Key Features

  • ABB SACE Tmax XT7L series.
  • 1600 A rated current.
  • Ekip G Hi-Touch LSIG electronic release.
  • Designed for generator protection and low-voltage power distribution.
  • Three-pole configuration.
  • Fixed installation with front terminal connections.
  • Lever operating mechanism.
  • Solid-state electronic release technology.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • L interruption rating for high short-circuit performance.

Advanced Generator and Power Distribution Protection

Moulded case circuit breakers such as the ABB XT7L protect electrical circuits, generators and connected equipment against damaging overload, short-circuit and ground-fault conditions. The electronic trip unit monitors electrical conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping maintain safe and dependable operation across demanding low-voltage electrical installations.

The Ekip G Hi-Touch LSIG release provides advanced electronic protection for generator applications, combining long-time, short-time, instantaneous and ground-fault protection with the high breaking performance of the XT7L platform. This makes the 1SDA101009R1 particularly well suited to generator switchboards, industrial power systems and high-current distribution assemblies where precise protection and reliable fault interruption are required.

Typical Applications

  • Generator protection and generator control panels.
  • Industrial low-voltage switchboards.
  • Power generation and standby power systems.
  • High-current electrical distribution networks.
  • Industrial plants and manufacturing facilities.
  • Commercial and infrastructure power distribution systems.

Technical Specifications

Series SACE Tmax XT7
Order code 1SDA101009R1
Product type Moulded case circuit breaker
Application Generator protection and low-voltage power distribution
Rated uninterrupted current (Iu) 1600 A
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic release
Protection functions Long-time, short-time, instantaneous and ground-fault
Short-circuit breaking performance 120 kA
Interruption rating L
Frame size XT7
Number of poles 3
Version Fixed
Terminal connection Front terminals
Operating mechanism Lever
Standard IEC
EAN 8056221010634

Frequently Asked Questions

What is the ABB 1SDA101009R1 used for?

The ABB 1SDA101009R1 is an XT7L moulded case circuit breaker designed for generator protection and high-current low-voltage electrical distribution applications.

What is the rated current of the ABB 1SDA101009R1?

The circuit breaker has a rated uninterrupted current of 1600 A.

What protection unit is fitted to this circuit breaker?

The 1SDA101009R1 is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions.

What is the breaking performance of the XT7L 1600?

The XT7L version provides a high short-circuit breaking performance of 120 kA, making it suitable for demanding generator and industrial power distribution applications.

How is the ABB 1SDA101009R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a lever operating mechanism, designed for installation within low-voltage switchboards, generator panels and industrial power distribution assemblies.

Trusted Protection from ABB

ABB SACE Tmax XT circuit breakers are engineered for dependable low-voltage power protection, combining high short-circuit performance, advanced electronic trip technology and robust installation options for industrial, commercial and power generation applications.