1SDA101007R1 ABB XT7L 1000 Ekip G Hi-Touch LSIG 1000 A 3-Pole MCCB

1SDA101007R1 ABB XT7L 1000 Ekip G Hi-Touch LSIG 1000 A 3-Pole MCCB

ABB 1SDA101007R1 is a 1000 A three-pole fixed XT7L moulded-case circuit breaker with an Ekip G Hi-Touch LSIG electronic trip unit and 120 kA breaking capacity at 400–415 V AC for advanced generator and low-voltage power distribution protection.

SKU: 1SDA101007R1MPN: 1SDA101007R1
Price
List Price £11,001.96 ex VAT
Your Price (ex VAT) Save 25%
£8,251.47 25% OFF
You save £2,750.49 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,251.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,251.47

Why Choose the ABB 1SDA101007R1 XT7L 1000 Circuit Breaker?

The ABB 1SDA101007R1 is a high-performance three-pole moulded-case circuit breaker (MCCB) designed for advanced generator and low-voltage power distribution protection. Part of the ABB SACE Tmax XT7 range, this fixed circuit breaker combines a 1000 A rated current with an Ekip G Hi-Touch LSIG electronic trip unit for sophisticated and configurable electrical protection.

The integrated Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, selective short-time, instantaneous short-circuit and ground-fault protection functions. The Ekip G platform is suited to demanding generator, transformer and installation protection applications where precise protection settings and effective coordination are required.

The XT7L version is engineered for very high short-circuit performance, providing a rated ultimate breaking capacity of 120 kA at 400–415 V AC. The 1SDA101007R1 features a fixed three-pole construction with front terminals and a lever operating mechanism, providing a robust solution for generator switchboards, industrial distribution panels and critical electrical infrastructure.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded-case circuit breaker.
  • 1000 A rated current for demanding generator and power distribution applications.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit.
  • LSIG functionality provides overload, selective short-time, instantaneous and ground-fault protection.
  • 120 kA ultimate breaking capacity at 400–415 V AC for installations with very high prospective fault currents.
  • Suitable for advanced generator, transformer and installation protection.
  • Fixed three-pole construction with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT7L circuit breaker.
  • 1000 A rated current (In).
  • 1000 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • Ekip G Hi-Touch LSIG electronic trip unit.
  • Long-time overload (L) protection.
  • Selective short-time (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Ground-fault (G) protection.
  • L performance level for very high short-circuit breaking capability.
  • 120 kA breaking capacity at 400–415 V AC.
  • Fixed construction with front terminal connections.
  • Lever operating mechanism for direct manual operation.
  • Suitable for low-voltage systems up to 690 V AC.

Advanced Generator and Very High-Performance Circuit Protection

Moulded-case circuit breakers used in generator and high-current distribution systems must provide dependable protection against overloads, short circuits and ground faults. The ABB Ekip G Hi-Touch LSIG electronic trip unit combines configurable L, S, I and G protection functions with advanced electronic protection technology, enabling accurate fault response and effective coordination throughout demanding electrical networks.

The XT7L performance level is designed for installations requiring exceptionally high short-circuit breaking capability. Combined with its 1000 A current rating, Ekip G Hi-Touch protection and fixed front-terminal construction, the 1SDA101007R1 provides a dependable solution for generator switchboards, transformer protection, industrial plants, critical infrastructure and high-current power distribution systems.

Typical Applications

  • Generator protection and generator-fed distribution systems.
  • Transformer and installation protection.
  • Generator and critical-power switchboards.
  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • High-current feeder and cable protection.
  • Installations with very high prospective short-circuit currents.
  • Critical infrastructure and high-availability power systems.
  • OEM switchgear and electrical panel building.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101007R1
Product type Moulded-case circuit breaker (MCCB)
Frame XT7
Performance level L
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic trip unit
Protection functions L, S, I and G
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Number of poles 3
Rated voltage range 220–690 V AC
Rated ultimate breaking capacity (Icu) at 400–415 V AC 120 kA
Version Fixed
Terminal connection Front
Operating mechanism Lever
GTIN / EAN 8056221010610
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA101007R1 used for?

The ABB 1SDA101007R1 is a 1000 A moulded-case circuit breaker designed for advanced generator, transformer and low-voltage power distribution protection in demanding electrical installations.

What trip unit is fitted to the ABB 1SDA101007R1?

The circuit breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time overload, selective short-time, instantaneous short-circuit and ground-fault protection functions.

What does LSIG mean on the Ekip G Hi-Touch trip unit?

LSIG denotes long-time overload (L), selective short-time (S), instantaneous short-circuit (I) and ground-fault (G) protection functions.

What is the breaking capacity of the ABB XT7L 1000?

The XT7L provides a rated ultimate short-circuit breaking capacity of 120 kA at 400–415 V AC, making it suitable for installations with very high prospective fault currents.

Is the ABB 1SDA101007R1 suitable for generator protection?

Yes. The 1SDA101007R1 incorporates the Ekip G Hi-Touch LSIG electronic trip unit and is suitable for advanced generator, transformer and power distribution protection applications.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT circuit breakers combine high-performance fault interruption with advanced Ekip electronic protection technology, providing configurable protection and flexible integration for generator, industrial and critical low-voltage power distribution systems.