1SDA101001R1 ABB XT7L 1600 Ekip G Dip LS/I 1600A 3-Pole Circuit Breaker

1SDA101001R1 ABB XT7L 1600 Ekip G Dip LS/I 1600A 3-Pole Circuit Breaker

ABB 1SDA101001R1 is an XT7L 1600 A three-pole fixed moulded case circuit breaker with front terminals and an Ekip G Dip LS/I electronic trip unit for generator protection and high-performance low-voltage power distribution.

SKU: 1SDA101001R1MPN: 1SDA101001R1
Price
List Price £6,856.46 ex VAT
Your Price (ex VAT) Save 25%
£5,142.35 25% OFF
You save £1,714.12 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,142.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,142.35

Why Choose the ABB 1SDA101001R1 XT7L 1600 Circuit Breaker?

The ABB 1SDA101001R1 is a high-performance SACE Tmax XT7L moulded case circuit breaker (MCCB) designed for generator protection and demanding low-voltage electrical distribution applications. Configured as an XT7L 1600 Ekip G Dip LS/I In=1600A 3p F F, it combines a 1600 A rated current with an electronic Ekip G Dip LS/I solid-state trip unit and high short-circuit breaking performance.

As part of the advanced ABB SACE Tmax XT range, this circuit breaker provides reliable protection against overload and short-circuit conditions while offering electronic protection specifically suited to generator applications. The Ekip G Dip LS/I trip unit provides long-time, short-time and instantaneous protection functions, supporting effective protection and coordination within industrial power distribution systems.

With a rated uninterrupted current of 1600 A, an adjustable overload release range of 640–1600 A and an XT7L breaking performance of 120 kA, the 1SDA101001R1 is suitable for high-current installations where dependable fault protection is essential. Its three-pole fixed configuration with front terminals and lever operating mechanism enable straightforward integration into low-voltage switchboards, generator panels and industrial distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded case circuit breaker.
  • 1600 A rated uninterrupted current for high-current electrical distribution.
  • Dedicated Ekip G Dip LS/I electronic trip unit for generator protection.
  • 120 kA XT7L short-circuit breaking performance.
  • Adjustable overload release range of 640–1600 A.
  • Three-pole fixed construction with front terminals for switchboard installation.

Key Features

  • ABB SACE Tmax XT7L series.
  • 1600 A rated current.
  • Ekip G Dip LS/I solid-state release.
  • Designed for generator protection and low-voltage distribution.
  • Three-pole configuration.
  • Fixed installation with front terminal connections.
  • Lever operating mechanism.
  • Long-time, short-time and instantaneous protection functions.
  • L interruption rating for high short-circuit performance.
  • Suitable for systems with a rated voltage up to 690 V.

Reliable Generator and Power Distribution Protection

Moulded case circuit breakers such as the ABB XT7L protect electrical circuits, generators and connected equipment against damaging overload and short-circuit currents. The electronic trip unit monitors current conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping maintain safe and dependable operation of the electrical installation.

The Ekip G Dip LS/I release is designed for generator applications requiring accurate electronic protection and dependable short-circuit performance. Combined with the XT7L's high breaking capacity, adjustable overload protection and robust fixed construction, the 1SDA101001R1 is well suited to generator switchboards, industrial power systems and high-current low-voltage distribution assemblies.

Typical Applications

  • Generator protection and generator control panels.
  • Industrial low-voltage switchboards.
  • Power generation and standby power systems.
  • High-current electrical distribution networks.
  • Industrial plants and manufacturing facilities.
  • Commercial and infrastructure power distribution systems.

Technical Specifications

Series SACE Tmax XT7
Order code 1SDA101001R1
Product type Moulded case circuit breaker
Application Generator protection and low-voltage power distribution
Rated uninterrupted current (Iu) 1600 A
Overload release adjustment range 640–1600 A
Trip unit Ekip G Dip LS/I
Protection functions Long-time, short-time and instantaneous
Rated voltage 690 V
Short-circuit breaking performance 120 kA
Interruption rating L
Frame size XT7
Number of poles 3
Version Fixed
Terminal connection Front terminals
Operating mechanism Lever
Release type Solid-state electronic release
Standard IEC
UPC / EAN 8056221010559

Frequently Asked Questions

What is the ABB 1SDA101001R1 used for?

The ABB 1SDA101001R1 is an XT7L moulded case circuit breaker designed for generator protection and high-current low-voltage electrical distribution applications.

What is the rated current of the ABB 1SDA101001R1?

The circuit breaker has a rated uninterrupted current of 1600 A, with an adjustable overload release range of 640–1600 A.

What protection unit is fitted to this circuit breaker?

The 1SDA101001R1 is fitted with an Ekip G Dip LS/I electronic trip unit, providing long-time, short-time and instantaneous protection functions.

What is the breaking performance of the XT7L 1600?

The ABB XT7L version provides a high short-circuit breaking performance of 120 kA, making it suitable for demanding generator and industrial power distribution applications.

How is the ABB 1SDA101001R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a lever operating mechanism, designed for installation within low-voltage switchboards, generator panels and industrial power distribution assemblies.

Trusted Protection from ABB

ABB SACE Tmax XT circuit breakers are engineered for dependable low-voltage power protection, combining high breaking performance, advanced electronic trip technology and flexible installation for industrial, commercial and power generation applications.