ABB XT7L 1000 Ekip Touch Measuring LSIG 1SDA100979R1 is a fixed three-pole 1000 A moulded case circuit breaker with integrated electrical measurement, LSIG electronic protection, an operating voltage up to 690 V AC and a 120 kA ultimate breaking capacity at 400 V AC.
£6,116.74
The ABB XT7L 1000 Ekip Touch Measuring LSIG 1SDA100979R1 is a high-performance three-pole moulded case circuit breaker (MCCB) designed for advanced protection, measurement and switching in demanding low-voltage AC power distribution systems. Part of the ABB SACE Tmax XT7 range, this fixed circuit breaker combines a rated uninterrupted current of 1000 A with ABB's Ekip Touch Measuring LSIG solid-state electronic protection unit.
The Ekip Touch Measuring LSIG release combines long-time, short-time, instantaneous and ground-fault protection with integrated electrical measurement functionality. This provides a versatile platform for protecting feeders, transformers, generators and distribution systems while also giving operators access to useful electrical measurements for monitoring and power management.
The XT7L provides a rated ultimate short-circuit breaking capacity of 120 kA at 400 V AC and is suitable for operating voltages up to 690 V AC. Adjustable overload, delayed short-circuit and instantaneous protection settings provide flexibility for system coordination, while the fixed three-pole construction, front connections and lever operating mechanism support straightforward switchboard integration.
Moulded case circuit breakers such as the ABB XT7L provide essential protection for high-current electrical distribution systems. The Ekip Touch Measuring LSIG protection unit combines long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection, helping safeguard cables, switchgear and connected equipment while supporting coordinated protection throughout the electrical network.
The Measuring version of the Ekip Touch platform adds electrical measurement functionality to the protection system, allowing the circuit breaker to contribute useful operating data as well as fault protection. Combined with the XT7L's 1000 A rating and 120 kA breaking capacity at 400 V AC, the 1SDA100979R1 is well suited to modern switchboards where advanced protection, measurement and efficient power distribution management are required.
| Series | SACE Tmax XT |
|---|---|
| Order code | 1SDA100979R1 |
| EAN | 8056221010337 |
| Product type | Moulded case circuit breaker |
| Frame size | XT7 |
| Performance level | L |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational voltage | up to 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 120 kA |
| Overload release current setting | 400–1000 A |
| Short-time delayed short-circuit setting | 600–10000 A |
| Instantaneous short-circuit setting | 1500–15000 A |
| Number of poles | 3 |
| Release | Ekip Touch Measuring LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and ground fault |
| Measurement functionality | Integrated |
| Current type | AC |
| Installation version | Fixed |
| Main-circuit connection | Bolted connection |
| Terminal position | Front |
| Operating mechanism | Lever |
| Degree of protection | IP20 |
| Motor operating mechanism | Optional |
| Dimensions (W × H × D) | 210 × 268 × 166 mm |
| Weight | 9.7 kg |
The ABB 1SDA100979R1 is designed for protection, switching and electrical measurement in high-current low-voltage AC distribution systems, including feeders, transformers, generators, switchboards and industrial power distribution.
The breaker has a rated uninterrupted current of 1000 A. Its overload release setting can be adjusted from 400–1000 A.
The XT7L 1000 has a rated ultimate short-circuit breaking capacity of 120 kA at 400 V AC, providing high fault interruption capability for demanding low-voltage distribution systems.
The Ekip Touch Measuring LSIG electronic release combines long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection with integrated electrical measurement functionality.
This model is a fixed three-pole circuit breaker with front-positioned, bolted main-circuit connections and a lever operating mechanism for integration into low-voltage switchboards and power distribution assemblies.
ABB SACE Tmax XT moulded case circuit breakers combine high-performance circuit protection with advanced electronic and measurement functionality, providing dependable solutions for modern industrial, commercial and infrastructure power distribution systems.