1SDA100935R1 ABB XT7H 1000 Ekip G Dip LS/I 1000 A 3-Pole Generator Protection Circuit Breaker

1SDA100935R1 ABB XT7H 1000 Ekip G Dip LS/I 1000 A 3-Pole Generator Protection Circuit Breaker

ABB 1SDA100935R1 is an XT7H 1000 A three-pole fixed moulded case circuit breaker with an Ekip G Dip LS/I electronic trip unit for dependable protection of low-voltage generator circuits and power distribution systems.

SKU: 1SDA100935R1MPN: 1SDA100935R1
Price
List Price £4,066.31 ex VAT
Your Price (ex VAT) Save 25%
£3,049.73 25% OFF
You save £1,016.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,049.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,049.73

Why Choose the ABB XT7H 1000 Ekip G Dip LS/I 1SDA100935R1 Generator Protection Circuit Breaker?

The ABB XT7H 1000 Ekip G Dip LS/I 1SDA100935R1 is a high-performance moulded case circuit breaker (MCCB) for generator protection designed for demanding low-voltage power generation and distribution applications. As part of the ABB SACE Tmax XT series, this three-pole circuit breaker combines the XT7H platform with an Ekip G Dip LS/I electronic trip unit for reliable protection of generator-fed electrical systems.

The Ekip G Dip LS/I release provides long-time, short-time and instantaneous protection functions, helping protect generators, conductors and connected equipment against overload and short-circuit conditions. Its electronic protection technology supports dependable fault protection and coordination within industrial, commercial and infrastructure generator installations.

With a rated uninterrupted current of 1000 A, a rated operational voltage of 690 V AC and a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC, the 1SDA100935R1 provides robust performance for demanding generator circuits. Its fixed three-pole construction with front bolted connections and toggle operating mechanism supports practical integration into generator switchboards and low-voltage distribution assemblies.

Key Advantages

  • High-performance ABB XT7H moulded case circuit breaker suitable for generator and installation protection.
  • 1000 A rated uninterrupted current for substantial low-voltage generator circuits.
  • 70 kA ultimate short-circuit breaking capacity at 415 V AC for demanding fault conditions.
  • Ekip G Dip LS/I electronic trip unit for generator protection applications.
  • Long-time, short-time and instantaneous protection functions.
  • Three-pole fixed construction with front connections for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT7 frame with H short-circuit performance level.
  • 1000 A rated uninterrupted current.
  • Ekip G Dip LS/I electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Three-pole configuration.
  • Fixed installation with front bolted main-circuit connections.
  • Toggle operating mechanism.
  • IP20 degree of protection.

Advanced Protection for Generator-Fed Power Systems

Generator circuits require protection capable of responding reliably to overload and short-circuit conditions while accommodating the operating characteristics of generating equipment. The ABB XT7H provides high fault interruption performance, helping protect generators, cables, switchboards and downstream equipment against damaging electrical faults.

The Ekip G Dip LS/I electronic release provides long-time, short-time and instantaneous protection functions for generator applications. Combined with the XT7H platform's high breaking capacity and 20 kA short-time withstand current, this makes the 1SDA100935R1 suitable for standby generation, distributed generation and industrial power distribution systems requiring dependable protection and coordination.

Typical Applications

  • Low-voltage generator protection.
  • Standby and emergency power systems.
  • Generator control and distribution switchboards.
  • Industrial generation and cogeneration systems.
  • Commercial and infrastructure backup power installations.
  • Generator-fed low-voltage distribution networks.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA100935R1
Product type Moulded case circuit breaker for generator and installation protection
Frame size XT7
Short-circuit performance level H
Rated uninterrupted current (Iu) 1000 A
Rated current (In) 1000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 65 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated short-time withstand current (Icw) 20 kA
Trip unit Ekip G Dip LS/I
Release type Electronic
Protection functions Long-time, short-time and instantaneous
Integrated earth-fault protection No
Number of poles 3
Installation Fixed
Terminal position Front
Main circuit connection Bolted connection
Operating mechanism Toggle
Protection rating IP20
Power loss at rated operating conditions per pole 37 W
Electrical durability 3000 cycles
Mechanical durability 10000 cycles
Motor operator Optional
Standard IEC 60947-2
EAN 8056221009898

Frequently Asked Questions

What is the ABB 1SDA100935R1 used for?

The ABB 1SDA100935R1 is an XT7H moulded case circuit breaker suitable for generator and installation protection in high-current low-voltage power systems.

What is the current rating of this circuit breaker?

The XT7H 1SDA100935R1 has a rated uninterrupted current of 1000 A and a rated operational voltage of 690 V AC.

What protection does the Ekip G Dip LS/I trip unit provide?

The Ekip G Dip LS/I electronic trip unit provides long-time, short-time and instantaneous protection functions for overload and short-circuit protection.

What is the breaking capacity of the ABB XT7H 1SDA100935R1?

The circuit breaker has a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC, with ratings of 65 kA at 440 V AC, 50 kA at 500–525 V AC and 42 kA at 690 V AC.

How is the ABB XT7H 1SDA100935R1 installed?

This model uses a fixed three-pole configuration with front bolted main-circuit connections and a toggle operating mechanism, making it suitable for integration into generator switchboards and low-voltage distribution assemblies.

Trusted ABB Generator Protection Technology

ABB SACE Tmax XT circuit breakers combine dependable electrical protection, high short-circuit interruption performance and dedicated electronic generator protection technology for modern industrial, commercial and infrastructure power systems.