ABB 1SDA100899R1 XT7H 1000 is a 1000 A three-pole fixed moulded case circuit breaker with an Ekip Dip LSIG electronic trip unit, integrated earth-fault protection and 70 kA ultimate breaking capacity at 415 V AC for demanding low-voltage power distribution.

SKU: 1SDA100899R1MPN: 1SDA100899R1
Price
List Price £5,135.87 ex VAT
Your Price (ex VAT) Save 25%
£3,851.90 25% OFF
You save £1,283.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,851.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,851.90

Why Choose the ABB 1SDA100899R1 XT7H 1000 Circuit Breaker?

The ABB 1SDA100899R1, type XT7H 1000 Ekip Dip LSIG In=1000A 3p F F, is a high-performance moulded case circuit breaker (MCCB) for low-voltage power distribution. Part of the ABB SACE Tmax XT range, this XT7H breaker combines a 1000 A rated current with an Ekip Dip LSIG solid-state electronic trip unit for comprehensive overload, short-time, instantaneous short-circuit and earth-fault protection.

The Ekip Dip LSIG electronic release provides L, S, I and G protection functions, enabling coordinated protection against sustained overloads, short-circuit faults and earth faults. Its long-time overload setting is adjustable from 400–1000 A, while the instantaneous short-circuit protection range extends from 1500–15000 A, providing flexibility for demanding distribution applications.

The XT7H performance level is designed for installations with high prospective fault currents, providing an ultimate short-circuit breaking capacity of 70 kA at 415 V AC and 65 kA at 440 V AC. Its fixed three-pole construction, front terminals and lever operating mechanism provide a robust configuration for industrial switchboards, main distribution panels and high-current electrical assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT moulded case circuit breaker for demanding low-voltage distribution systems.
  • 1000 A rated current for high-current industrial and commercial applications.
  • Ekip Dip LSIG electronic trip unit for comprehensive configurable circuit protection.
  • Long-time, short-time, instantaneous and earth-fault protection in one electronic release.
  • 400–1000 A adjustable overload protection range for effective circuit coordination.
  • 1500–15000 A instantaneous short-circuit protection range.
  • 70 kA ultimate short-circuit breaking capacity at 415 V AC with XT7H performance.
  • Three-pole fixed configuration with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT7H series.
  • 1000 A rated current.
  • Ekip Dip LSIG solid-state electronic release.
  • L, S, I and G protection functions for overload, short-circuit and earth-fault protection.
  • 400–1000 A adjustable long-time overload protection range.
  • 1500–15000 A instantaneous short-circuit protection range.
  • Integrated earth-fault protection.
  • H-performance interruption level for systems with high prospective fault currents.
  • 70 kA Icu at 415 V AC.
  • Three-pole fixed-mounted design with front terminals and lever operating mechanism.

Comprehensive Electronic Protection for Power Distribution Systems

The ABB Ekip Dip LSIG electronic trip unit combines long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection in a single solid-state release. The L, S, I and G functions support selective protection coordination throughout complex low-voltage networks while providing dedicated protection against faults between live conductors and earth.

The XT7H version is engineered for installations where substantial short-circuit interruption capability is required. With its 1000 A rating, 70 kA ultimate breaking capacity at 415 V AC and fixed front-terminal configuration, the 1SDA100899R1 is particularly suited to industrial switchboards, main distribution panels, infrastructure installations and high-current feeder circuits requiring comprehensive electronic protection.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main and sub-main electrical distribution.
  • High-fault-level power distribution systems.
  • Circuits requiring integrated earth-fault protection.
  • Commercial and industrial electrical installations.
  • Manufacturing and process plant switchboards.
  • Infrastructure and critical-power systems.
  • High-current feeders and distribution circuits.

Technical Specifications

Series SACE Tmax XT
Frame size XT7
Order code / MPN 1SDA100899R1
Alternate catalogue number XT7HE310DGFF000XXX
Product type Moulded case circuit breaker
Application Low-voltage power distribution protection
Rated current (In) 1000 A
Number of poles 3
Current type AC
Trip unit Ekip Dip LSIG
Release type Solid-state electronic
Protection functions L, S, I, G
Long-time overload adjustment range 400–1000 A
Instantaneous short-circuit protection range 1500–15000 A
Earth-fault protection Integrated
Short-circuit performance level H
Ultimate breaking capacity (Icu) at 240 V AC 100 kA
Ultimate breaking capacity (Icu) at 415 V AC 70 kA
Ultimate breaking capacity (Icu) at 440 V AC 65 kA
Service breaking capacity (Ics) at 415 V AC 70 kA
Ics / Icu ratio at 415 V AC 100%
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Lever
Complete device with protection unit Yes
Product net width 210 mm
Product net height 268 mm
Product net depth 166 mm
Product net weight 9.7 kg
Standard IEC 60947-2
EAN / GTIN 8056221009539

Frequently Asked Questions

What is the ABB 1SDA100899R1 used for?

The ABB 1SDA100899R1 is a 1000 A moulded case circuit breaker designed for protection and switching of demanding low-voltage power distribution circuits, including systems requiring integrated earth-fault protection.

What trip unit is fitted to the ABB 1SDA100899R1?

The breaker is fitted with an Ekip Dip LSIG solid-state electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection functions.

What is the rated current of the ABB XT7H 1000?

The ABB 1SDA100899R1 has a rated current of 1000 A, with its long-time overload protection adjustable from 400–1000 A.

What protection and breaking performance does the XT7H 1000 provide?

The Ekip Dip LSIG provides L, S, I and G protection, including integrated earth-fault protection, while the XT7H breaker provides an ultimate short-circuit breaking capacity of 70 kA at 415 V AC and 65 kA at 440 V AC.

How is the ABB 1SDA100899R1 installed?

This model is a fixed, three-pole circuit breaker with front terminals and a lever operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers combine configurable electronic protection with high short-circuit performance, providing panel builders and electrical engineers with dependable overload, short-circuit and earth-fault protection for demanding industrial and commercial low-voltage distribution systems.