1SDA100896R1 ABB XT7H 1250 Ekip Dip LSI 1250A 3-Pole Circuit Breaker

1SDA100896R1 ABB XT7H 1250 Ekip Dip LSI 1250A 3-Pole Circuit Breaker

ABB 1SDA100896R1 XT7H 1250 is a 1250 A three-pole fixed moulded case circuit breaker with an Ekip Dip LSI electronic trip unit and 70 kA breaking capacity at 415 V AC for demanding low-voltage power distribution protection.

SKU: 1SDA100896R1MPN: 1SDA100896R1
Price
List Price £5,173.48 ex VAT
Your Price (ex VAT) Save 25%
£3,880.11 25% OFF
You save £1,293.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,880.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,880.11

Why Choose the ABB 1SDA100896R1 XT7H 1250 Circuit Breaker?

The ABB 1SDA100896R1, type XT7H 1250 Ekip Dip LSI In=1250A 3p F F, is a high-performance moulded case circuit breaker (MCCB) for low-voltage power distribution. Part of the ABB SACE Tmax XT range, this XT7H breaker combines a 1250 A rated uninterrupted current with an Ekip Dip LSI solid-state electronic trip unit for dependable overload, short-time and instantaneous short-circuit protection.

The Ekip Dip LSI electronic release provides L, S and I protection functions, giving engineers configurable protection against sustained overloads and short-circuit faults. The inclusion of short-time protection supports selective coordination between upstream and downstream protective devices, helping maintain continuity in complex industrial and commercial distribution systems.

The XT7H performance level provides an ultimate short-circuit breaking capacity of 70 kA at 415 V AC. Combined with a rated operational voltage of 690 V AC, fixed three-pole construction, front terminals and lever operating mechanism, the 1SDA100896R1 provides a robust solution for industrial switchboards, main distribution panels and high-current feeder circuits.

Key Advantages

  • High-performance ABB SACE Tmax XT moulded case circuit breaker for demanding low-voltage distribution systems.
  • 1250 A rated uninterrupted current for high-current industrial and commercial applications.
  • Ekip Dip LSI electronic trip unit for overload, short-time and instantaneous short-circuit protection.
  • Short-time protection supports improved selectivity and coordination between protective devices.
  • 70 kA short-circuit breaking capacity at 415 V AC with XT7H performance.
  • 690 V AC rated operational voltage for demanding low-voltage installations.
  • Three-pole fixed configuration with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT7H series.
  • 1250 A rated current.
  • Ekip Dip LSI solid-state electronic release.
  • L, S and I protection functions for overload, short-time and instantaneous short-circuit protection.
  • H-performance interruption level for systems with high prospective fault currents.
  • 70 kA breaking capacity at 415 V AC.
  • 690 V AC rated operational voltage.
  • Three-pole fixed-mounted design.
  • Front terminals for main-circuit connection.
  • Lever operating mechanism.

Selective Electronic Protection for Power Distribution Systems

The ABB Ekip Dip LSI electronic trip unit combines long-time overload, short-time short-circuit and instantaneous short-circuit protection in a solid-state release. The addition of short-time protection supports improved selectivity between protective devices, helping engineers coordinate fault-clearing characteristics throughout complex low-voltage distribution networks while maintaining rapid interruption of severe faults.

The XT7H version is engineered for installations where substantial short-circuit performance is required. With its 1250 A rating, 70 kA breaking capacity at 415 V AC and fixed front-terminal configuration, the 1SDA100896R1 is particularly suited to industrial switchboards, main distribution panels, infrastructure installations and high-current feeder circuits.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main and sub-main electrical distribution.
  • High-fault-level power distribution systems.
  • Commercial and industrial electrical installations.
  • Manufacturing and process plant switchboards.
  • Infrastructure and utility electrical systems.
  • High-current feeders and distribution circuits.
  • Large electrical distribution panels and switchgear assemblies.

Technical Specifications

Series SACE Tmax XT
Frame size XT7
Order code / MPN 1SDA100896R1
Product type Moulded case circuit breaker
Application Low-voltage power distribution protection
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage (Ue) 690 V AC
Number of poles 3
Current type AC
Trip unit Ekip Dip LSI
Release type Solid-state electronic
Protection functions L, S, I
Short-circuit performance level H
Breaking capacity at 415 V AC 70 kA
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Lever
Complete device with protection unit Yes
Power loss 57 W
Dimensions (W × H × D) 210 × 268 × 166 mm
Net weight 9.7 kg
Conformity standard IEC 60947-2
EAN / GTIN 8056221009508

Frequently Asked Questions

What is the ABB 1SDA100896R1 used for?

The ABB 1SDA100896R1 is a 1250 A moulded case circuit breaker designed for protection and switching of demanding low-voltage power distribution circuits in industrial, commercial and infrastructure installations.

What trip unit is fitted to the ABB 1SDA100896R1?

The breaker is fitted with an Ekip Dip LSI solid-state electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the rated current of the ABB XT7H 1250?

The ABB 1SDA100896R1 has a rated current and rated uninterrupted current of 1250 A.

What breaking capacity does the XT7H 1250 provide?

The XT7H is ABB's H-performance version of the XT7 frame and provides a short-circuit breaking capacity of 70 kA at 415 V AC, making it suitable for installations with high prospective fault currents.

How is the ABB 1SDA100896R1 installed?

This model is a fixed, three-pole circuit breaker with front terminals and a lever operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers combine configurable electronic protection with high short-circuit performance, providing panel builders and electrical engineers with dependable protection for demanding industrial, commercial and infrastructure low-voltage distribution systems.