ABB 1SDA100887R1 XT7S 1000 is a 1000 A three-pole fixed moulded case circuit breaker with an Ekip Dip LIG electronic trip unit for transformer, generator and low-voltage electrical installation protection.
£3,073.22
The ABB 1SDA100887R1, type XT7S 1000 Ekip Dip LIG In=1000A 3p F F, is a high-performance moulded case circuit breaker (MCCB) for transformer, generator and electrical installation protection. Part of the ABB SACE Tmax XT range, this XT7S breaker combines a 1000 A rated uninterrupted current with an Ekip Dip LIG solid-state electronic trip unit for dependable overload, instantaneous short-circuit and earth-fault protection.
The Ekip Dip LIG electronic release provides L, I and G protection functions, covering long-time overload, instantaneous short-circuit and earth-fault conditions. Its adjustable overload and instantaneous protection settings allow the breaker to be coordinated with the connected circuit, providing reliable electronic protection for demanding low-voltage power distribution systems.
With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 380–440 V AC, the XT7S 1000 is designed for demanding industrial installations. Its fixed three-pole construction, front terminals, bolted main-circuit connections and lever operating mechanism make it well suited to switchboards, generator systems, transformer protection and high-current electrical distribution.
The ABB Ekip Dip LIG trip unit combines long-time overload, instantaneous short-circuit and earth-fault protection in an electronic release designed for dependable low-voltage circuit protection. Adjustable protection settings allow the breaker characteristics to be coordinated with transformers, generators, cables and other equipment within the electrical installation.
The SACE Tmax XT platform combines high breaking performance, compact construction and electronic protection for modern industrial power distribution. The XT7S 1000 is particularly suited to applications requiring a 1000 A fixed MCCB with front connections, earth-fault protection and dependable isolation of high-current circuits.
| Series | SACE Tmax XT |
|---|---|
| Frame size | XT7 |
| Order code / MPN | 1SDA100887R1 |
| Product type | Moulded case circuit breaker |
| Application | Transformer, generator and electrical installation protection |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Number of poles | 3 |
| Trip unit | Ekip Dip LIG |
| Release type | Solid-state electronic |
| Protection functions | L, I, G |
| Overload release adjustment range | 400–1000 A |
| Instantaneous short-circuit release adjustment range | 1000–10000 A |
| Ultimate breaking capacity (Icu) at 220–240 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 380–440 V AC | 50 kA |
| Ultimate breaking capacity (Icu) at 500–525 V AC | 45 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 30 kA |
| Service breaking capacity (Ics) at 380–440 V AC | 50 kA |
| Rated short-time withstand current (Icw) | 20 kA |
| Short-circuit performance level | S |
| Mounting type | Fixed |
| Terminal connection | Front terminals |
| Main circuit connection | Bolted connection |
| Operating mechanism | Lever |
| Complete device with protection unit | Yes |
| Standard | IEC 60947-2 |
| Mechanical endurance | 10000 cycles |
| Power loss at rated operating conditions | 37 W per pole |
| Dimensions (W × H × D) | 210 × 268 × 166 mm |
| Weight | 9.7 kg |
| EAN | 8056221009416 |
The ABB 1SDA100887R1 is a 1000 A moulded case circuit breaker designed for transformer, generator and general electrical installation protection in demanding low-voltage power systems.
The breaker is fitted with an Ekip Dip LIG electronic trip unit, providing long-time overload, instantaneous short-circuit and earth-fault protection functions.
The 1SDA100887R1 has a rated uninterrupted current of 1000 A, with its overload release adjustable from 400–1000 A.
The XT7S S-performance version provides an ultimate short-circuit breaking capacity of 50 kA at 380–440 V AC, with ratings of 45 kA at 500–525 V AC and 30 kA at 690 V AC.
This model is a fixed, three-pole circuit breaker with front terminals, bolted main-circuit connections and a lever operating mechanism for integration into low-voltage switchboards and distribution assemblies.
ABB SACE Tmax XT circuit breakers combine compact construction with configurable electronic protection, providing panel builders and electrical engineers with dependable protection for transformer, generator and industrial low-voltage distribution applications.