1SDA100850R1 ABB XT7S 800 Ekip Touch Measuring LSIG 800 A 3-Pole Circuit Breaker

1SDA100850R1 ABB XT7S 800 Ekip Touch Measuring LSIG 800 A 3-Pole Circuit Breaker

ABB 1SDA100850R1 is a fixed three-pole SACE Tmax XT7S 800 A moulded-case circuit breaker with front terminals and an Ekip Touch Measuring LSIG solid-state electronic trip unit combining overload, short-circuit and ground-fault protection with electrical measurement functionality.

SKU: 1SDA100850R1MPN: 1SDA100850R1
Price
List Price £4,995.42 ex VAT
Your Price (ex VAT) Save 25%
£3,746.57 25% OFF
You save £1,248.86 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,746.57
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,746.57

Why Choose the ABB XT7S 800 Ekip Touch Measuring LSIG 1SDA100850R1 Circuit Breaker?

The ABB 1SDA100850R1 is a high-performance SACE Tmax XT7S 800 moulded-case circuit breaker (MCCB) designed for protection and electrical measurement in demanding low-voltage distribution systems. It combines a fixed three-pole XT7S circuit breaker with ABB's advanced Ekip Touch Measuring LSIG solid-state electronic trip unit.

Rated at 800 A, this XT7S configuration provides long-time, short-time, instantaneous and ground-fault protection functions. The Ekip Touch Measuring release combines comprehensive electronic circuit protection with electrical measurement capabilities, making the breaker particularly suitable for installations where dependable protection and enhanced visibility of electrical operating conditions are required.

The 1SDA100850R1 is a three-pole, fixed circuit breaker with front terminals. As an XT7S model, it belongs to ABB's 50 kA performance class, providing substantial short-circuit protection capability for industrial, commercial and infrastructure distribution systems.

Key Advantages

  • High-performance ABB SACE Tmax XT7S moulded-case circuit breaker.
  • 800 A rated current for high-current low-voltage distribution applications.
  • Ekip Touch Measuring LSIG electronic trip unit combines circuit protection with electrical measurement functionality.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Three-pole configuration for three-phase electrical distribution.
  • 50 kA XT7S performance class for demanding short-circuit protection requirements.
  • Fixed installation with front terminals for switchboard integration.
  • Touch-based electronic interface supports protection configuration and access to operating information.

Key Features

  • ABB SACE Tmax XT7S 800 circuit breaker.
  • 800 A rated current.
  • Three-pole configuration.
  • Ekip Touch Measuring LSIG solid-state electronic trip unit.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • Integrated electrical measurement functionality.
  • Touch-based electronic trip-unit interface.
  • S interruption rating.
  • Fixed circuit-breaker installation.
  • Front electrical terminals.
  • Designed for AC low-voltage electrical distribution.
  • Part of the ABB SACE Tmax XT platform.

Advanced Circuit Protection with Measurement and Ground-Fault Protection

The ABB Tmax XT7S protects low-voltage distribution circuits by interrupting current when overload, short-circuit or ground-fault conditions exceed configured protection thresholds. Its Ekip Touch Measuring LSIG solid-state release provides long-time, short-time, instantaneous and ground-fault protection functions while adding electrical measurement capabilities for improved visibility of system operating conditions.

This combination of protection and measurement makes the 1SDA100850R1 particularly suitable for modern switchboards where electrical performance information is valuable alongside comprehensive circuit protection. Its fixed construction, front terminals and 800 A rating provide a practical configuration for integration into high-current industrial and commercial distribution assemblies.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main electrical switchboards and distribution panels.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process-industry power systems.
  • Three-phase feeder and distribution circuit protection.
  • Installations requiring integrated electrical measurement and ground-fault protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100850R1
Product type Moulded-case circuit breaker (MCCB)
Frame size XT7
Rated current 800 A
Number of poles 3
Trip unit Ekip Touch Measuring LSIG
Release technology Solid-state electronic
Protection functions LSIG
Long-time protection Overload protection
Short-time protection Short-circuit protection
Instantaneous protection Short-circuit protection
Ground-fault protection Included
Measurement functionality Included
Interruption rating S
XT7S performance class 50 kA
Mounting type Fixed
Terminal type Front terminals
Standard IEC
Product weight 9.7 kg

Frequently Asked Questions

What is the ABB 1SDA100850R1 used for?

The ABB 1SDA100850R1 is an 800 A three-pole moulded-case circuit breaker designed for protection and electrical measurement in high-current low-voltage distribution systems.

What is the rated current of the ABB XT7S 1SDA100850R1?

The circuit breaker has a rated current of 800 A.

What trip unit does the 1SDA100850R1 use?

The breaker uses an ABB Ekip Touch Measuring LSIG solid-state electronic trip unit, combining long-time, short-time, instantaneous and ground-fault protection with electrical measurement capabilities.

What does Measuring LSIG mean on the ABB Ekip Touch trip unit?

LSIG identifies long-time, short-time, instantaneous and ground-fault protection functions, while the Measuring version of Ekip Touch adds electrical measurement functionality for enhanced visibility of the distribution system.

How is the ABB XT7S 800 1SDA100850R1 installed?

This version is a fixed three-pole circuit breaker with front terminals, making it suitable for integration into compatible electrical switchboards and distribution assemblies.

Trusted ABB Circuit Protection and Measurement

ABB SACE Tmax XT moulded-case circuit breakers combine robust switching technology with advanced Ekip electronic protection and measurement capabilities to support dependable, intelligent low-voltage power distribution.