ABB 1SDA100781R1 is an XT6H 1000 fixed four-pole moulded case circuit breaker with a 1000 A rating, front terminals and an Ekip Dip LSIG electronic trip unit for comprehensive high-current power distribution protection.
£3,825.66
The ABB XT6H 1000 Ekip Dip LSIG 1SDA100781R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Tmax XT series, this XT6H breaker combines a 1000 A rated current with an Ekip Dip LSIG solid-state electronic trip unit for comprehensive circuit protection.
This fixed circuit breaker features front terminals and an Ekip Dip LSIG electronic release, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection functions. The XT6H performance level delivers a rated ultimate short-circuit breaking capacity of 70 kA at 380–415 V AC, making it suitable for installations where substantial prospective fault currents may occur.
With a rated operational voltage of up to 690 V AC, a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 8 kV, the XT6H 1000 is engineered for robust industrial power distribution. Its four-pole fixed configuration and 1000 A current rating make it particularly suitable for switchboards, distribution panels, infrastructure and high-power industrial installations.
Moulded case circuit breakers such as the ABB Tmax XT6H protect electrical distribution systems against abnormal current and fault conditions while providing reliable switching and isolation. The Ekip Dip LSIG electronic release provides multiple protection functions covering overloads, delayed and instantaneous short circuits and ground faults, allowing the breaker to provide comprehensive protection for demanding electrical networks.
The XT6H performance level is designed for installations with substantial prospective fault currents. With a rated ultimate breaking capacity of 70 kA at 380–415 V AC and a rated uninterrupted current of 1000 A, this breaker is well suited to high-power feeders, main distribution circuits and industrial switchboards where reliable fault interruption is essential.
| Series | SACE Tmax XT |
|---|---|
| Frame / sub-type | XT6 |
| ABB order code | 1SDA100781R1 |
| EAN | 8056221008358 |
| Product type | Moulded case circuit breaker |
| Application | Power distribution |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 4 |
| Trip unit | Ekip Dip LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and ground fault |
| Short-circuit performance level | H |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate breaking capacity (Icu) at 220–240 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 380–415 V AC | 70 kA |
| Ultimate breaking capacity (Icu) at 440–525 V AC | 50 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 25 kA |
| Ultimate breaking capacity (Icu) at 250 V DC | 70 kA with 2 poles in series |
| Ultimate breaking capacity (Icu) at 500 V DC | 50 kA with 2 poles in series |
| Ultimate breaking capacity (Icu) at 750 V DC | 36 kA with 3 poles in series |
| Rated short-time withstand current (Icw) | 10 kA |
| Current type | AC |
| Mounting version | Fixed |
| Terminal connection | Front |
| Power loss | 83.5 W |
| Dimensions (W × H × D) | 280 × 268 × 103.5 mm |
| Net weight | 12 kg |
| Standard | IEC 60947-2 |
This moulded case circuit breaker is designed for protecting and switching high-current electrical distribution circuits in industrial, commercial and infrastructure installations.
The XT6H 1000 has a rated current and rated uninterrupted current of 1000 A.
The breaker is fitted with an Ekip Dip LSIG electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection functions.
The XT6H 1000 has a rated ultimate short-circuit breaking capacity of 70 kA at 380–415 V AC, with the available breaking capacity varying according to the system voltage.
This model is a fixed four-pole circuit breaker with front terminals, designed for installation within low-voltage switchboards and electrical distribution assemblies.
ABB SACE Tmax XT moulded case circuit breakers are engineered for reliable electrical protection, high breaking performance and efficient integration into modern industrial and commercial power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.