1SDA100779R1 ABB XT6H 1000 Ekip Dip LSI 1000 A 4-Pole Fixed Circuit Breaker

1SDA100779R1 ABB XT6H 1000 Ekip Dip LSI 1000 A 4-Pole Fixed Circuit Breaker

ABB 1SDA100779R1 is an XT6H 1000 A 4-pole fixed moulded-case circuit breaker with front terminals and an Ekip Dip LSI solid-state electronic release providing long-time, short-time and instantaneous protection.

SKU: 1SDA100779R1MPN: 1SDA100779R1
Price
List Price £4,882.53 ex VAT
Your Price (ex VAT) Save 25%
£3,661.90 25% OFF
You save £1,220.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,661.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,661.90

Why Choose the ABB 1SDA100779R1 XT6H 1000 Ekip Dip LSI Circuit Breaker?

The ABB 1SDA100779R1 is a SACE Tmax XT6H moulded-case circuit breaker designed for high-current low-voltage power distribution and protection applications. Rated at 1000 A, this fixed 4-pole circuit breaker features front terminals and an Ekip Dip LSI solid-state electronic trip unit.

The Ekip Dip LSI release combines long-time overload, short-time short-circuit and instantaneous short-circuit protection. Its electronic DIP-switch interface enables protection parameters to be configured for coordination with feeders, cables and downstream protective devices, making it a practical solution for demanding distribution networks.

The XT6H version provides a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC and 25 kA at 690 V AC. Combined with its 1000 A rating and four-pole construction, the 1SDA100779R1 provides robust protection for industrial and commercial systems with high prospective fault currents.

Key Advantages

  • 1000 A rated current for high-current low-voltage distribution applications.
  • 4-pole construction for three-phase systems incorporating neutral switching.
  • Ekip Dip LSI electronic protection covers overload and multiple levels of short-circuit fault.
  • Short-circuit protection adjustable over a 1–10 × In range with time-delay capability.
  • 70 kA ultimate breaking capacity at 415 V AC for installations with demanding fault levels.
  • Fixed construction with front terminals for integration into compatible switchboards and distribution assemblies.

Key Features

  • ABB SACE Tmax XT6H moulded-case circuit breaker.
  • 1000 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • Ekip Dip LSI electronic trip unit.
  • Solid-state electronic release for AC applications.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Short-circuit protection adjustable over 1–10 × In with time-delay capability.
  • Fixed circuit breaker execution.
  • Front terminals for main power connections.
  • H breaking-capacity class.
  • 70 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 25 kA ultimate short-circuit breaking capacity at 690 V AC.

High-Breaking-Capacity Electronic LSI Protection

Electronic LSI protection combines three complementary protection functions within a single circuit breaker release. Long-time protection responds to sustained overload conditions, short-time protection provides a controlled response to short-circuit currents for improved selectivity, and instantaneous protection provides rapid interruption of severe short-circuit faults.

The ABB 1SDA100779R1 combines these functions with the 1000 A XT6H platform and a 70 kA at 415 V AC ultimate breaking capacity. Its four-pole construction, fixed mounting and front terminals make it particularly suitable for high-current switchboards where dependable fault interruption, neutral switching and configurable electronic protection are required.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Four-pole three-phase electrical distribution systems.
  • Main and sub-main power distribution.
  • High-current feeder and cable protection.
  • Installations with high prospective short-circuit currents.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure power distribution.
  • Transformer-fed distribution systems.
  • ABB Tmax XT6 installations requiring 1000 A LSI electronic protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA100779R1
Extended product type XT6H 1000 Ekip Dip LSI In=1000 4p F F
Product type Moulded-case circuit breaker (MCCB)
Frame size XT6
Breaking-capacity class H
Rated current 1000 A
Rated uninterrupted current (Iu) 1000 A
Number of poles 4
Trip unit Ekip Dip LSI
Release type Solid-state electronic
Current type AC
Protection functions LSI
Short-circuit adjustment range 1–10 × In
Short-circuit time delay Adjustable
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 25 kA
Rated operational voltage 690 V AC
Mounting execution Fixed
Terminal arrangement Front terminals
GTIN / EAN 8056221008334
Product net weight 12 kg
ABB EcoSolutions Yes

Frequently Asked Questions

What is the ABB 1SDA100779R1?

The ABB 1SDA100779R1 is a Tmax XT6H 1000 A 4-pole moulded-case circuit breaker with fixed mounting, front terminals and an Ekip Dip LSI solid-state electronic trip unit.

What is the rated current of the ABB 1SDA100779R1?

The circuit breaker has a rated uninterrupted current of 1000 A.

What does LSI mean on the Ekip Dip trip unit?

LSI identifies the trip unit's long-time (L), short-time (S) and instantaneous (I) protection functions, providing electronic protection against sustained overloads and different levels of short-circuit fault.

What is the breaking capacity of the ABB XT6H 1000?

The XT6H has a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC and 25 kA at 690 V AC.

Is the ABB 1SDA100779R1 a fixed 4-pole circuit breaker?

Yes. The 1SDA100779R1 is a fixed 4-pole circuit breaker with front terminals, designed for integration into compatible low-voltage switchboards and power distribution assemblies.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT moulded-case circuit breakers and Ekip electronic releases combine high fault-interruption performance with configurable protection to safeguard demanding industrial, commercial and infrastructure low-voltage electrical distribution systems.