1SDA100754R1 ABB XT6S 800 Ekip Dip LS/I 4-Pole Circuit Breaker

1SDA100754R1 ABB XT6S 800 Ekip Dip LS/I 4-Pole Circuit Breaker

ABB 1SDA100754R1 is an 800 A four-pole SACE Tmax XT6S moulded case circuit breaker with an Ekip Dip LS/I electronic trip unit, fixed mounting and front terminals for adjustable low-voltage power distribution protection.

SKU: 1SDA100754R1MPN: 1SDA100754R1
Price
List Price £3,064.39 ex VAT
Your Price (ex VAT) Save 25%
£2,298.29 25% OFF
You save £766.10 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,298.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,298.29

Why Choose the ABB XT6S 800 Ekip Dip LS/I 1SDA100754R1 Circuit Breaker?

The ABB 1SDA100754R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for dependable protection and isolation in demanding industrial and commercial low-voltage power distribution systems. Part of the ABB SACE Tmax XT series, this XT6S 800 model combines fixed mounting, front terminals and an Ekip Dip LS/I solid-state electronic trip unit.

Rated at 800 A, the XT6S is engineered for high-current distribution applications requiring adjustable electronic protection. Its Ekip Dip LS/I trip unit provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection, helping safeguard cables, switchboards and connected electrical equipment against damaging overcurrent conditions.

The XT6S performance level provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC, with a rated operational voltage of 690 V AC. Its four-pole configuration, fixed installation format and front-connected terminals make the 1SDA100754R1 well suited to high-current switchboards and three-phase distribution systems requiring switched neutral capability.

Key Advantages

  • High-current 800 A moulded case circuit breaker for demanding power distribution applications.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • Ekip Dip LS/I electronic trip unit for adjustable overload and short-circuit protection.
  • 50 kA ultimate breaking capacity at 415 V AC for robust fault interruption.
  • Adjustable overload protection across 320–800 A.
  • Fixed mounting with front terminals for practical switchboard integration.

Key Features

  • ABB SACE Tmax XT, XT6 frame.
  • 800 A rated current.
  • Four-pole fixed circuit breaker.
  • Ekip Dip LS/I solid-state electronic release.
  • Long-time overload protection adjustable from 0.4–1 × In.
  • Short-circuit protection adjustment up to 10 × In.
  • Short-time or instantaneous short-circuit protection functionality.
  • 50 kA Icu at 415 V AC.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • IP20 protection rating.

Adjustable Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB XT6S protect electrical distribution systems against abnormal current conditions while also providing circuit switching and isolation. The Ekip Dip electronic release monitors current and operates the breaker when configured protection thresholds are exceeded, helping protect conductors, switchgear and connected electrical equipment.

The LS/I protection configuration gives the 1SDA100754R1 flexibility for coordination within high-current distribution systems. Its long-time overload protection can be adjusted from 320–800 A, while short-circuit protection settings extend from 800–8000 A, allowing protection characteristics to be matched to the requirements of the electrical installation.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and high-current feeder circuit protection.
  • Commercial building electrical distribution systems.
  • Manufacturing and process plant power distribution.
  • Transformer, generator and installation protection.
  • Four-pole three-phase distribution systems requiring neutral switching.

Technical Specifications

Series SACE Tmax XT
Frame size XT6
Order code / SKU 1SDA100754R1
Product group T-Max XT 250 Range
Product type Moulded case circuit breaker
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) at 415 V AC 50 kA
Rated short-time withstand current (Icw) 10 kA
Trip unit Ekip Dip LS/I
Release type Solid-state electronic
Overload protection adjustment range 320–800 A
Short-time short-circuit adjustment range 800–8000 A
Instantaneous short-circuit adjustment range 800–8000 A
Interruption performance level S
Mounting version Fixed
Terminal connection Front
Main circuit connection Bolt connection
Operating element Toggle
Protection rating IP20
Power loss 53.4 W
Electrical durability 5000 cycles
Motor drive Optional
DIN rail mounting No
Net weight 12 kg
Standards IEC
GTIN / UPC 8056221008082

Frequently Asked Questions

What is the ABB 1SDA100754R1 used for?

The ABB 1SDA100754R1 is an 800 A four-pole moulded case circuit breaker designed to provide adjustable overload and short-circuit protection in industrial and commercial low-voltage power distribution systems.

What trip unit is fitted to the ABB 1SDA100754R1?

The breaker is fitted with an Ekip Dip LS/I solid-state electronic trip unit, providing long-time overload protection together with short-time or instantaneous short-circuit protection.

What is the breaking capacity of the ABB XT6S 800?

The XT6S performance level provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

What protection adjustment ranges are available on the 1SDA100754R1?

The overload protection is adjustable from 320–800 A, while the short-time and instantaneous short-circuit protection ranges extend from 800–8000 A.

How is the ABB 1SDA100754R1 installed?

This model is a fixed four-pole circuit breaker with front bolt-connected terminals, designed for integration into low-voltage switchboards and electrical distribution panels.

Trusted Power Distribution Technology from ABB

ABB SACE Tmax XT moulded case circuit breakers are engineered for reliable low-voltage power distribution, combining robust interruption performance, adjustable electronic protection and practical installation options for demanding industrial and commercial electrical systems.