1SDA100560R1 XT5H 4 pole 400A MCCB Breaking Part with front terminals

1SDA100560R1 XT5H 4 pole 400A MCCB Breaking Part with front terminals

ABB 1SDA100560R1 XT5H 400 four-pole fixed moulded case circuit breaker breaking part with front terminals, rated at 400 A for industrial low-voltage power distribution.

SKU: 1SDA100560R1Alt SKU: XT5H 400 BREAKING PART 4p F FMPN: 1SDA100560R1
Price
List Price £913.04 ex VAT
Your Price (ex VAT) Save 25%
£684.78 25% OFF
You save £228.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £684.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£684.78

Why Choose the ABB 1SDA100560R1 XT5H 400 Breaking Part?

The ABB 1SDA100560R1 is a high-performance four-pole moulded case circuit breaker breaking part designed for dependable protection and switching in industrial and commercial low-voltage electrical distribution systems. Part of the advanced ABB SACE Tmax XT5 series, this fixed breaker component combines compact dimensions with high short-circuit interruption performance.

Identified as the XT5H 400 Breaking Part 4p F F, this unit features a fixed mounting configuration and front terminals for straightforward installation within switchboards and distribution panels. Its H-level short-circuit performance makes it suitable for electrical systems where robust protection against high prospective fault currents is required.

With a rated uninterrupted current of 400 A and a rated operational voltage of up to 690 V AC or 750 V DC, the ABB 1SDA100560R1 supports demanding power-distribution applications. Its four-pole construction allows simultaneous switching of three phases and the neutral conductor, while the modular Tmax XT design enables combination with a compatible ABB protection trip unit.

Key Advantages

  • High-performance ABB Tmax XT5H breaking part for low-voltage circuit protection.
  • 400 A rated uninterrupted current for industrial and commercial installations.
  • Short-circuit breaking capacity of up to 100 kA, depending on operating voltage.
  • Four-pole fixed configuration for three-phase systems with neutral switching.
  • Front-terminal arrangement simplifies switchboard wiring and maintenance access.
  • Compatible with suitable ABB Tmax XT5 protection trip units and accessories.

Key Features

  • ABB SACE Tmax XT5 series.
  • XT5H 400 Breaking Part 4p F F configuration.
  • 400 A rated uninterrupted current.
  • Four-pole construction.
  • Fixed mounting version with front terminals.
  • H short-circuit performance level.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 8 kV.
  • Designed in accordance with applicable IEC standards.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers protect electrical installations by interrupting current during overload and short-circuit conditions when used with an appropriate protection trip unit. The ABB Tmax XT5 platform is engineered to deliver reliable performance while reducing the space required inside low-voltage switchboards.

The ABB 1SDA100560R1 provides high interruption performance across a broad range of AC and DC operating voltages. Its fixed design, four-pole construction and front-terminal configuration make it well suited to panel builders, original equipment manufacturers and industrial facilities requiring a durable and accessible circuit-protection solution.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main and sub-distribution electrical panels.
  • Three-phase systems requiring neutral conductor switching.
  • Commercial building power-distribution systems.
  • Manufacturing and process-control installations.
  • Transformer, generator and installation protection.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 400 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 70 kA
Manufacturer ABB
Series SACE Tmax XT5
Model XT5H 400 Breaking Part 4p F F
Product ID 1SDA100560R1
Product type Moulded case circuit breaker breaking part
Rated uninterrupted current 400 A
Number of poles 4
Mounting version Fixed
Terminal connection Front terminals
Rated operational voltage Up to 690 V AC / 750 V DC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate breaking capacity at 415 V AC 70 kA
Rated service breaking capacity at 415 V AC 70 kA
Rated ultimate breaking capacity at 690 V AC 40 kA
Rated short-time withstand current 5 kA
Short-circuit performance level H
Electrical durability 7,000 operating cycles
Mechanical durability 20,000 operating cycles
Product dimensions (H × W × D) 205 × 186 × 103.5 mm
Net weight 4.15 kg
EAN 8056221006361
Country of origin Italy
Standards IEC 60947
HS Code 85389099
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA100560R1 used for?

The ABB 1SDA100560R1 is a four-pole Tmax XT5H breaking part used within a moulded case circuit breaker assembly for protecting and switching low-voltage electrical distribution systems.

What is the rated current of this breaking part?

The ABB 1SDA100560R1 has a rated uninterrupted current of 400 A.

What mounting and terminal configuration does it use?

This model has a fixed mounting configuration with front terminals for connection inside electrical switchboards.

What is its breaking capacity at 415 V AC?

The XT5H breaking part has a rated ultimate and service short-circuit breaking capacity of 70 kA at 415 V AC.

Does the ABB 1SDA100560R1 include a trip unit?

This product is supplied as a breaking part and must be combined with a compatible ABB Tmax XT5 protection trip unit and any accessories required for the intended application.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely specified by panel builders, electrical engineers and industrial operators for reliable circuit protection, compact installation and dependable short-circuit performance.