ABB 1SDA100553R1 SACE Tmax XT5N 630 A four-pole fixed breaking part for assembly with a compatible ABB XT5 trip unit.

SKU: 1SDA100553R1Alt SKU: XT5N 630 BREAKING PART 4p F FMPN: 1SDA100553R1
Price
List Price £1,492.24 ex VAT
Your Price (ex VAT) Save 25%
£1,119.18 25% OFF
You save £373.06 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,119.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,119.18

Why Choose the ABB 1SDA100553R1 Tmax XT5N Breaking Part?

The ABB 1SDA100553R1 is a 630 A frame-size breaking part for ABB SACE Tmax XT5 moulded case circuit breaker assemblies. Designed as part of the ABB Tmax XT5N range, it features a fixed four-pole configuration with front terminals for integration into industrial and commercial low-voltage power distribution systems.

Unlike a complete moulded case circuit breaker, the ABB 1SDA100553R1 is supplied as the breaker body or breaking part and does not include a protection trip unit. A compatible ABB XT5 trip unit must be selected separately according to the required rated current, protection functions and system-coordination requirements.

The four-pole construction allows all three phase conductors and the neutral conductor to be switched together. With its XT5N interruption-performance level, robust operating mechanism and compact format, this breaking part provides a flexible foundation for building a customised circuit protection solution.

Key Advantages

  • 630 A frame-size breaking part for ABB Tmax XT5 assemblies.
  • Compatible with a wide range of ABB XT5 electronic and thermal-magnetic trip units.
  • Four-pole configuration for simultaneous switching of phases and neutral.
  • Fixed mounting arrangement for dependable switchboard installation.
  • Front terminals simplify cable and busbar connections.
  • Modular design enables tailored protection solutions.

Key Features

  • ABB SACE Tmax XT5N series.
  • 630 A maximum frame rating.
  • Four-pole breaking part.
  • Normal (N) interruption-performance level.
  • Fixed installation configuration.
  • Front terminal arrangement.
  • Compatible with ABB XT5 protection trip units.
  • Designed for modular MCCB assembly.

A Flexible Foundation for Circuit Protection

The ABB 1SDA100553R1 provides the switching and interruption mechanism for a customised XT5 circuit breaker assembly. By selecting a compatible ABB XT5 trip unit separately, engineers can configure the protection characteristics to suit the installation's electrical requirements.

This modular approach allows overload, short-circuit and advanced electronic protection functions to be selected according to the application while simplifying maintenance and future upgrades.

Designed for Three-Phase Distribution Systems

Its four-pole design enables simultaneous switching of all three phase conductors together with the neutral conductor, making it suitable for three-phase, four-wire power distribution systems where neutral isolation is specified.

The fixed construction and front terminal arrangement provide straightforward integration into industrial switchboards, commercial distribution panels and OEM equipment.

Typical Applications

  • Industrial switchboards.
  • Main and sub-main distribution boards.
  • Commercial electrical installations.
  • Motor control centres.
  • OEM machinery.
  • Low-voltage power distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Power distribution
Current 630 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 36 kA
Manufacturer ABB
Series SACE Tmax XT
Extended product type XT5N 630 BREAKING PART 4p F F
Product ID 1SDA100553R1
Product type Moulded case circuit breaker breaking part
Frame size XT5
Maximum frame current 630 A
Number of poles 4
Interruption-performance level N
Typical breaking capacity at 415 V AC 36 kA
Rated operational voltage Up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Mounting type Fixed
Terminal type Front terminals
Trip unit included No
Compatible trip-unit platform ABB XT5
Dimensions (H × W × D) 205 × 186 × 103.5 mm
Weight Approx. 4.7 kg
Standards IEC 60947-2
HS Code 85389099
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA100553R1?

The ABB 1SDA100553R1 is a four-pole XT5N 630 A breaking part used to build a complete ABB Tmax XT5 moulded case circuit breaker.

Does this include a trip unit?

No. The ABB 1SDA100553R1 is supplied as a breaking part only and requires a compatible ABB XT5 trip unit.

What is the frame rating?

The product is based on the 630 A XT5 frame. The final protection rating depends on the compatible trip unit fitted.

How many poles does this breaking part have?

This model has four poles, allowing simultaneous switching of three phases and the neutral conductor.

Where is this product typically used?

It is commonly used in industrial switchboards, commercial distribution panels, motor control centres and OEM electrical assemblies.

Engineered for Professional Power Distribution