1SDA100525R1 ABB XT5H 630 TMA 630-6300 4p F F InN=100%In Moulded Case Circuit Breaker

1SDA100525R1 ABB XT5H 630 TMA 630-6300 4p F F InN=100%In Moulded Case Circuit Breaker

ABB 1SDA100525R1 XT5H 630 fixed four-pole moulded case circuit breaker with front terminals, a 630 A TMA thermomagnetic release and neutral protection rated at 100% of the phase setting.

SKU: 1SDA100525R1MPN: 1SDA100525R1
Price
List Price £2,600.18 ex VAT
Your Price (ex VAT) Save 25%
£1,950.14 25% OFF
You save £650.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,950.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,950.14

Why Choose the ABB XT5H 630 TMA 630-6300 4p F F InN=100%In?

The ABB 1SDA100525R1 is a high-performance Tmax XT5H moulded case circuit breaker (MCCB) designed for dependable protection of demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax XT series, this fixed four-pole circuit breaker combines an XT5 630 A frame with a TMA thermomagnetic trip unit rated at 630 A.

The TMA release provides thermal overload and instantaneous magnetic short-circuit protection without requiring an electronic trip unit. Its protection arrangement is suited to high-current distribution circuits where straightforward thermomagnetic protection and robust fault interruption are required.

This four-pole version incorporates neutral protection rated at 100% of the phase setting, making it suitable for three-phase four-wire systems where the neutral conductor requires full-current protection. Fixed mounting and front terminals support straightforward integration into industrial and commercial switchboards.

Key Advantages

  • High-performance ABB Tmax XT5H moulded case circuit breaker for demanding low-voltage installations.
  • 630 A TMA thermomagnetic trip unit provides overload and short-circuit protection.
  • Thermomagnetic operation provides dependable circuit protection without an electronic trip unit.
  • Four-pole construction enables switching and protection of three phases and neutral.
  • Neutral protection at 100% of the phase setting for full-current neutral protection.
  • Fixed mounting with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT5H circuit breaker.
  • 630 A rated current.
  • TMA thermomagnetic release.
  • Thermal overload protection.
  • Instantaneous magnetic short-circuit protection.
  • 6300 A magnetic protection reference.
  • Four-pole construction.
  • Neutral protection: 100% of phase setting.
  • Fixed mounting configuration.
  • Front terminals for main circuit connections.
  • XT5 frame size with H short-circuit performance level.
  • Designed for demanding low-voltage power distribution applications.

High-Performance Four-Pole Distribution Protection

Moulded case circuit breakers such as the ABB Tmax XT5 protect electrical distribution circuits, cables and connected equipment against excessive current caused by overloads and short circuits. The TMA thermomagnetic release combines a thermal element for sustained overload protection with a magnetic element for rapid interruption of severe short-circuit currents.

The four-pole construction of the 1SDA100525R1 enables switching of all three phases and the neutral conductor, while its 100% neutral protection provides full-current protection for the neutral. Combined with its 630 A rating, fixed mounting, front terminals and XT5H performance class, the breaker is well suited to substantial industrial and commercial distribution systems.

Typical Applications

  • Industrial low-voltage distribution systems.
  • Main and sub-distribution switchboards.
  • Three-phase four-wire feeder circuits.
  • Systems requiring full-current neutral protection.
  • Manufacturing and process installations.
  • Commercial and infrastructure power distribution.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA100525R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Frame rating 630 A
Short-circuit performance level H
Rated current (In) 630 A
Trip unit TMA thermomagnetic release
Protection functions Thermal overload and magnetic short-circuit protection
Magnetic protection reference 6300 A
Number of poles 4
Neutral protection 100% of phase setting
Mounting Fixed
Terminal configuration Front terminals

Frequently Asked Questions

What is the ABB 1SDA100525R1 used for?

The ABB 1SDA100525R1 is a Tmax XT5H four-pole moulded case circuit breaker designed to provide thermomagnetic overload and short-circuit protection in demanding low-voltage distribution systems.

What is the rated current of the ABB XT5H 630 TMA 630-6300?

The circuit breaker is fitted with a 630 A TMA thermomagnetic trip unit for high-current low-voltage circuit protection.

What does InN=100%In mean on the ABB 1SDA100525R1?

InN=100%In means the neutral protection is rated at 100% of the phase current setting, allowing the neutral conductor to receive full-current protection.

What protection does the TMA trip unit provide?

The TMA thermomagnetic release provides thermal protection against sustained overloads and magnetic protection for rapid interruption of short-circuit currents.

How is the ABB 1SDA100525R1 installed?

This model is a fixed four-pole circuit breaker with front terminals, making it suitable for integration into compatible industrial switchboards and low-voltage distribution panels.

Trusted Circuit Protection from ABB