1SDA100523R1 ABB XT5H 630 TMA 500-5000 500A 4-Pole Circuit Breaker

1SDA100523R1 ABB XT5H 630 TMA 500-5000 500A 4-Pole Circuit Breaker

ABB 1SDA100523R1 XT5H 630 is a 500 A four-pole fixed moulded case circuit breaker with a TMA 500-5000 thermomagnetic trip unit and fully rated neutral for transformer, generator and low-voltage distribution protection.

SKU: 1SDA100523R1MPN: 1SDA100523R1
Price
List Price £2,600.18 ex VAT
Your Price (ex VAT) Save 25%
£1,950.14 25% OFF
You save £650.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,950.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,950.14

Why Choose the ABB 1SDA100523R1 XT5H 630 Circuit Breaker?

The ABB 1SDA100523R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for transformer, generator and low-voltage distribution protection. Part of the ABB SACE Tmax XT series, this XT5H 630 breaker combines a high-breaking-capacity platform with a TMA thermomagnetic trip unit for dependable overload and short-circuit protection.

The circuit breaker uses the XT5 630 A frame with a 500 A rated current. Its TMA 500-5000 thermomagnetic release combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection, enabling the breaker to protect demanding industrial distribution circuits against sustained overcurrents and severe electrical faults.

The XT5H configuration provides high short-circuit interruption performance, while its four-pole construction incorporates a neutral rated at 100% of In. This fully rated neutral makes the 1SDA100523R1 particularly suitable for three-phase four-wire systems where the neutral conductor must carry the same rated current as the phase conductors.

Key Advantages

  • High-performance ABB Tmax XT moulded case circuit breaker for transformer, generator and distribution protection.
  • 500 A rated current within the XT5 630 A frame.
  • XT5H high-breaking-capacity configuration for demanding electrical installations.
  • TMA thermomagnetic trip unit for combined overload and short-circuit protection.
  • Instantaneous magnetic protection adjustable from 2500–5000 A.
  • Four-pole configuration with neutral rated at 100% of In.

Key Features

  • ABB SACE Tmax XT series.
  • XT5H 630 frame configuration.
  • 500 A rated current.
  • TMA 500-5000 thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • Instantaneous magnetic short-circuit protection adjustable from 2500–5000 A.
  • H high-breaking-capacity performance level.
  • Four-pole configuration for three-phase four-wire systems.
  • Neutral rated at 100% of In.
  • Fixed mounting with front main-circuit terminals.

High-Performance Transformer, Generator and Distribution Protection

The ABB XT5H platform is designed for low-voltage installations requiring dependable overload protection together with high short-circuit interruption capability. The TMA thermomagnetic release combines thermal overload protection with adjustable instantaneous magnetic protection, providing a robust protection solution for transformers, generators, feeders and industrial distribution circuits.

With its 500 A rated current and 100% rated neutral, the 1SDA100523R1 is particularly suited to three-phase four-wire installations where substantial neutral currents may be present. Its fixed front-connected construction provides practical switchboard integration, while the XT5H performance level supports applications with demanding prospective short-circuit currents.

Typical Applications

  • Transformer protection and distribution switchboards.
  • Generator protection and generator panels.
  • Industrial low-voltage power distribution.
  • Three-phase four-wire systems requiring a fully rated neutral.
  • Main and sub-distribution switchboards.
  • Industrial installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100523R1
Product type Moulded case circuit breaker
Application Transformer, generator and electrical distribution protection
Frame size XT5
Frame rating 630 A
Rated current (In) 500 A
Number of poles 4
Neutral rating 100% of In
Trip unit TMA 500-5000
Release type Thermomagnetic
Instantaneous short-circuit setting 2500–5000 A
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Short-circuit performance level H
Mounting version Fixed
Terminal connection Front
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA100523R1 used for?

The ABB 1SDA100523R1 is a four-pole moulded case circuit breaker designed for transformer, generator and low-voltage distribution protection, combining a TMA thermomagnetic trip unit with the high-performance XT5H platform.

What is the rated current of the ABB 1SDA100523R1?

The circuit breaker has a rated current of 500 A and uses the ABB XT5 630 A frame.

What protection does the TMA 500-5000 trip unit provide?

The TMA thermomagnetic trip unit provides thermal overload protection together with adjustable instantaneous magnetic short-circuit protection, with the instantaneous setting ranging from 2500–5000 A.

What does InN=100%In mean on the ABB 1SDA100523R1?

InN=100%In means the neutral pole is rated at 100% of the phase rated current. This provides a fully rated neutral for three-phase four-wire systems where the neutral may need to carry the same rated current as the phase conductors.

How is the ABB 1SDA100523R1 installed?

The 1SDA100523R1 is a fixed four-pole circuit breaker with front terminals, making it suitable for integration into industrial switchboards, generator panels and low-voltage distribution assemblies.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, dependable thermomagnetic protection and high short-circuit performance for transformer, generator and industrial power distribution systems.