1SDA100522R1 ABB XT5H 630 TMA 500-5000 500A 4-Pole Circuit Breaker

1SDA100522R1 ABB XT5H 630 TMA 500-5000 500A 4-Pole Circuit Breaker

ABB 1SDA100522R1 XT5H 630 is a 500 A four-pole fixed moulded case circuit breaker with a TMA 500-5000 thermomagnetic trip unit, 50% rated neutral and 70 kA breaking capacity at 380–415 V AC for transformer, generator and distribution protection.

SKU: 1SDA100522R1MPN: 1SDA100522R1
Price
List Price £2,730.18 ex VAT
Your Price (ex VAT) Save 25%
£2,047.64 25% OFF
You save £682.55 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,047.64
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,047.64

Why Choose the ABB 1SDA100522R1 XT5H 630 Circuit Breaker?

The ABB 1SDA100522R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for transformer, generator and low-voltage installation protection. Part of the ABB SACE Tmax XT series, this XT5H 630 breaker combines high short-circuit interruption capability with a TMA thermomagnetic trip unit for dependable overload and short-circuit protection.

The circuit breaker uses the XT5 630 A frame with a 500 A rated current. Its TMA 500-5000 thermomagnetic release provides adjustable thermal overload protection from 350–500 A together with instantaneous magnetic short-circuit protection adjustable from 2500–5000 A, providing flexible protection for demanding power distribution circuits.

The XT5H configuration provides a rated ultimate short-circuit breaking capacity of 70 kA at 380–415 V AC. Its four-pole construction features a neutral rated at 50% of the phase current, while fixed mounting and front terminal connections support straightforward integration into industrial switchboards, generator panels and three-phase four-wire distribution systems.

Key Advantages

  • High-performance ABB Tmax XT moulded case circuit breaker for transformer, generator and distribution protection.
  • 500 A rated current within the XT5 630 A frame.
  • 70 kA breaking capacity at 380–415 V AC for demanding fault-current environments.
  • TMA thermomagnetic trip unit for combined overload and short-circuit protection.
  • Adjustable instantaneous magnetic protection from 2500–5000 A.
  • Four-pole configuration with neutral rated at 50% of In.

Key Features

  • ABB SACE Tmax XT series.
  • XT5H 630 frame configuration.
  • 500 A rated current.
  • TMA 500-5000 thermomagnetic trip unit.
  • Adjustable thermal overload protection from 350–500 A.
  • Instantaneous short-circuit protection adjustable from 2500–5000 A.
  • H high-breaking-capacity performance level.
  • 70 kA Icu at 380–415 V AC.
  • Four-pole configuration with neutral rated at 50% of the phase current.
  • Fixed mounting with front main-circuit terminals.

High-Performance Transformer, Generator and Distribution Protection

The ABB XT5H platform is designed for low-voltage installations requiring robust overload protection and high short-circuit interruption capability. Its TMA thermomagnetic release combines adjustable thermal protection with adjustable instantaneous magnetic protection, allowing the breaker to respond effectively to sustained overloads and severe short-circuit faults in transformer, generator and distribution circuits.

With a 500 A rated current, 70 kA breaking capacity at 380–415 V AC and a neutral rated at 50% of In, the 1SDA100522R1 is particularly suited to three-phase four-wire systems where a half-rated neutral is appropriate. Its fixed front-connected construction provides a compact and practical solution for industrial switchboards and low-voltage distribution assemblies.

Typical Applications

  • Transformer protection and distribution switchboards.
  • Generator protection and generator panels.
  • Industrial low-voltage power distribution.
  • Three-phase four-wire systems with 50% rated neutral requirements.
  • Main and sub-distribution switchboards.
  • Industrial installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100522R1
GTIN / EAN 8056221005982
Product type Moulded case circuit breaker
Application Transformer, generator and installation protection
Frame size XT5
Frame rating / rated uninterrupted current (Iu) 630 A
Rated current (In) 500 A
Number of poles 4
Neutral rating 50% of In
Trip unit TMA 500-5000
Release type Thermomagnetic
Thermal overload setting range 350–500 A
Instantaneous short-circuit setting (I3) 2500–5000 A
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity (Icu) at 380 V AC 70 kA
Rated ultimate breaking capacity (Icu) at 415 V AC 70 kA
Rated ultimate breaking capacity (Icu) at 440 V AC 65 kA
Rated ultimate breaking capacity (Icu) at 500–525 V AC 50 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 40 kA
Rated short-time withstand current (Icw) 6 kA
Short-circuit performance level H
Mounting version Fixed
Terminal connection Front
Power loss 33.5 W
Mechanical durability 20,000 cycles
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA100522R1 used for?

The ABB 1SDA100522R1 is a four-pole moulded case circuit breaker designed for transformer, generator and low-voltage installation protection, combining a TMA thermomagnetic trip unit with the high-breaking-capacity XT5H platform.

What is the rated current of the ABB 1SDA100522R1?

The circuit breaker has a rated current of 500 A and uses the ABB XT5 630 A frame. Its thermal overload setting can be adjusted from 350–500 A.

What protection does the TMA 500-5000 trip unit provide?

The TMA thermomagnetic trip unit provides adjustable thermal overload protection from 350–500 A and instantaneous magnetic short-circuit protection adjustable from 2500–5000 A.

What is the breaking capacity of the ABB XT5H 630?

The XT5H configuration provides a rated ultimate short-circuit breaking capacity of 70 kA at 380–415 V AC, with additional ratings including 65 kA at 440 V AC, 50 kA at 500–525 V AC and 40 kA at 690 V AC.

What does InN=50%In mean on the ABB 1SDA100522R1?

InN=50%In means the neutral pole is rated at 50% of the phase rated current. On this 500 A breaker, the neutral is therefore configured for a 50% current rating relative to the phase conductors.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, dependable thermomagnetic protection and high short-circuit performance for transformer, generator and industrial power distribution systems.